Download  Print this page

Irving IRHEDV32 Installation Instructions & Homeowner's Manual

Direct vent insert
Hide thumbs

Advertisement

WARNING! IF THE INFORMATION IN
THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE,PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch.
* Do not use any phone in your building.
* Immediately call your gas supplier
from your neighbours phone. Follow
the gas suppliers instructions.
* If you cannot reach your gas supplier
call the fire department.
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
*
Installation and service must be
performed by a qualified installer,
service agency or your gas supplier.
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
10003929
Installation Instructions &
Homeowner's Manual
DIRECT VENT
INSERT
MODEL
IRHEDV32
10003929
01/02 Rev. 0
1

Advertisement

Table of Contents
loading

  Related Manuals for Irving IRHEDV32

  Summary of Contents for Irving IRHEDV32

  • Page 1 Installation and service must be performed by a qualified installer, service agency or your gas supplier. Installation Instructions & INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Homeowner's Manual DIRECT VENT INSERT MODEL IRHEDV32 10003929 01/02 Rev. 0...
  • Page 2: Table Of Contents

    Troubleshooting Gas Control (820 Millivolt Gas Valve) ... 13 Troubleshooting Gas Control (Honeywell) ... 14 Replacement Parts List (Pictorial) ...15 Replacement Parts List ... 16 Trim Options ...17 A) A-Trim Options for IRHEDV32 ... 17 B) Remote Control...26 Venting Components ...27 10003929 TABLE OF CONTENTS A1 - RHESS/RHESL/RHESSD/RHESLD &...
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 or .2 Installation codes for Gas Burning Appliances and Equipment. FOR U.S.A Installations follow local codes and/or the current National Fuel Gas Code.
  • Page 4: Fireplace & Trim Dimensions

    U - Firebox depth at insert back height (V) V - Insert back height SS or SSD Trim SL or SLD Trim SXL Trim BSL Trim BXL Trim 10003929 3" (75mm) IRHEDV32 5/8" 3/8" 29" 15/16" 1065 33" 44" 1118 28"...
  • Page 5: Gas Specifications

    Take a minute and plan out the gas,venting and electrical route. It is best to start with the gas line first followed by the chimney liner (See page 9). IRHEDV32 CERTIFIED TO: ANSI.Z21.88b-1999 / CSA 2.33b - M99 Vented Gas Fireplace Heaters...
  • Page 6: Installation Of Trim Switch For Rp Gas Valves

    INSTALLATION OF TRIM SWITCH FOR RP GAS VALVES 1. Thread wire through openings on the right side of fireplace. Do not cut wire or insulation on metal edges. 2. Slide switch assembly from the back, between subframe and trim, then fasten the screw. (Fig. 3) 3.
  • Page 7: Liner Installation

    LINER INSTALLATION - Fig. 6 The collar extending down from the termi- nation base is the air intake connector. Be sure the flex vent, which is connected to this collar, is also connected to the labelled air intake flue collar on the fireplace. Make sure the Flex vent is attached on the correct collar and cap for exhaust as well.
  • Page 8: Fan Kit

    DAMPER FLUE COLLAR PLATE UNIT DAMPER FRONT FRAME UNIT FLUE COLLAR PLATE MOVE BACK MAKE SURE THE FLUE COLLAR PLATE IS IN CONTACT WITH THE BACK EDGE OF THE CABINET TOP FASTENER PLATE PLATE FLUE COLLAR MACHINE SCREW AFTER FASTENED 10003929 3"...
  • Page 9: Operating Instructions

    Fig. 16 for proper location). 8. Place top right log (KR6) onto locator notches. Ensure log is secure. 9. Place top left log (KR5) onto locator notches. Ensure log is secure. Fig. 14 IRHEDV32 GLASS FRAME 10/24 NUT Fig. 15 INSTALLATION OF LOGS &...
  • Page 10: Large Lava Rock Placement

    (Place refractory in fireplace side and slide it forward into side support angle on fireplace front. Leading edge of refractory must be completely behind side support angle of IRHEDV32 for proper placement). 7. Now carefully slide in back side of refractory against fireplace side.
  • Page 11: Flame Adjustment

    It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the pictorials illustrated below (Fig.19 and 20). If any of the flames appear abnormal call a service person. SIT Pilot PSE Pilot IRHEDV32 Fig. 19 Fig. 20...
  • Page 12: Lighting & Operating Instructions

    LIGHTING AND OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: A. This fireplace has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the fireplace area for gas. Be sure to smell next to the floor be- cause some gas is heavier than air and will settle on the floor.
  • Page 13: Troubleshooting Gas Control (820 Millivolt Gas Valve)

    TROUBLE SHOOTING THE GAS CONTROL SYSTEM Note: Before trouble shooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES 1. Spark ignitor will not light A.
  • Page 14: Troubleshooting Gas Control (Honeywell)

    TROUBLE SHOOTING THE GAS CONTROL SYSTEM START • GAS SUPPLY ON PILOT LIGHTS WITH PIEZO IGNITOR PILOT STAYS LIT PILOT LIGHTS MAIN BURNER SYSTEM OK. 10003929 HONEYWELL MILLIVOLT VALVE CHECK • SUPPLY LINE HOOKED UP • SHUTOFF VALVE OPEN • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.
  • Page 15: Replacement Parts List (Pictorial)

    REPLACEMENT PARTS 10a/b 8 a/b 11 a/b 13 18 9 a/b 23 a/b IRHEDV32 10003929...
  • Page 16: Replacement Parts List

    Speed Control Knob Glass with Gasket Gasket Glass Frame Window Remote Switch Remote Wire Harness with Terminals Ceramic Refractory Kit 10003929 IRHEDV32 57896 10001454 57897 10000198 57904 57803 SEE RATING PLATE FOR ORIFICE SIZE SEE RATING PLATE FOR ORIFICE SIZE...
  • Page 17: Trim Options

    A-TRIM OPTIONS FOR RHEDV32 IMPORTANT: Only Trim Panel Assemblies approved by Vermont Castings Majestic Products Company can be used. A1) RHESS, RHESL, RHESSD, RHESLD & RHESXL TRIMS FRAME ASSEMBLY RHESS, RHESL, RHESSD, RHESLD and RHESXL 1. Lay Trim Top Facing and Trim Side Facings, face down on to an even surface such as a table or floor.
  • Page 18 FRAME MOUNTING GENERAL INFORMATION The Decorative Front Frame should be installed last after all other work, such as gas connections, venting, etc., has been completed and thoroughly checked and tested for operation, leaks and proper installations requirements. Fit Decorative Frame to the fireplace and fasten (Fig. 25). AS SHOWN FROM FRONT Plastic on the trim must be removed before mounting onto the fireplace.
  • Page 19 TRIM REPLACEMENT PARTS LIST All repair parts will be available from your local dealer. When ordering, always give the following information: Model and serial number, part description with finish and part number; KEY DESCRIPTION Trim Frame Top, Flat Black Trim Frame Left, Flat Black Trim Frame Right, Flat Black Trim Top Deflector Trim Top Channel...
  • Page 20: A2) Rhebsl & Rhebxl Trims

    A2) RHEBSL & RHEBXL TRIMS TRIM ASSEMBLY RHEBSL 1. Install trim channels (left and right sides). Use two screws to assemble each piece. 2. Slide on the trim top channel and fasten it from the back side. 3. Install the trim top deflector and use two screws to fasten it.
  • Page 21: A3 - Rhefa & Rhefp Trims

    A3) RHEFA and RHEFP TRIMS TRIM ASSEMBLY 1. Remove the front glass (see "Glass Frame Re- moval" section). 2. Install support window trim channel, top and bottom brass trim by using the shortest black screw. (Fig. 43 & 44). TRIM-TOP GLASS FRAME TRIM-BOTTOM Louvre...
  • Page 22: A4 - Hebtkp/Hesbtkp/Hecbtk/Hecbtkmb & Hebta

    A4) HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA TRIMS HECBTK Cast bay window and grills in classic black trim kit HECBKMB Cast bay window and grills in midnight black porcelain enamel trim kit HESBTKP Steel bay window with polished brass and cast grills in classic black trim kit HEBTKP Steel bay window and bay louvres with polished brass trim kit Install the bay window after all other installation work has been completed, thoroughly checked, and tested for operation, leaks...
  • Page 23 1) Reposition controls. a) Remove the Fan Speed Control Box (Fig. 33). b) Attach the Fan Speed Control Box to the Bracket (Fig. 34) and install the Bracket into the Cabinet. Only for RN/RP VALVE units. c) Install the Control Knobs Extensions onto the appropriate Control Valve Knobs (Fig. 34). On units fitted with a Honeywell brand control valve the location of the control knobs and the ignitor button may vary slightly from those shown in Fig.
  • Page 24 Fig. 37. Hang the Window Grille or the Steel Frame onto the lower tabs of the Hanging Brackets. Fig. 39. Attach magnets and brass trim to the steel frame. 10003929 Fig. 38. Engage the slots in the Upper Grille Top Louvre with the upper tabs of the Hang- ing Brackets.
  • Page 25 TRIM REPLACEMENT PARTS LIST IMPORTANT: Only Trim Panel Assemblies Approved by Vermont Castings Majestic Products Company Can Be Used on These Products. ALL repair parts will be available from your local dealer. When ordering, always give the following information: Model and serial number, part description with finish and part number; HEBTKP KEY DESCRIPTION 1 Trim Window Top/Bottom...
  • Page 26: A5 - Cast Trims

    Cast Surround And Flat Face HECBL Cast Surround Black HECBLUE Cast Surround Blue HECCG Cast Surround Charcoal Grey HECGR Cast Surround Green CSSP Polished Brass Small Trim for Cast Surround CSLP Polished Brass Large Trim for Cast Surround (to be used with CSSP) Convert Insert Into a Freestanding Stove Note: 1) Requires Bay Window Face Kit 2) Vent starter kit FSHEDVSK must be installed to use any of the...
  • Page 27: Venting Components

    FLEX VENT 25 FT. LENGTH FLEX VENT 35 FT. LENGTH 10003929 VENTING COMPONENTS (Fit Typical 8" x 12" and 9" x 13" flue Tile) Kit Includes: A - 8" x 12" Vent Termination (x1) HIGH TEMPERATURE SEALANT B - Stainless Steel Clamps 3"-3.5" (x4) C - Hardware Package (x1) D - High Temperature Sealant (x1) Kit Includes:...