PREFACE Copyright This publication, including all photographs, illustrations, and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any material contained herein, may be reproduced without written consent of manufacturer. Copyright 2019 MITAC COMPUTING TECHNOLOGY CORPORATION. All rights ®...
Page 3
FCC Declaration ● Notice for the USA Compliance Information Statement (Declaration of Conformity Procedure) DoC FCC Part 15: This device complies with part 15 of the FCC Rules. This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: ‧This device may not cause harmful interference.
Page 4
Warning This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference. CAUTION Lithium battery included with this board. Do not puncture, mutilate, or dispose of battery in fire. There will be danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer.
Page 5
How this guide is organized This guide contains the following parts: Chapter 1: Overview This chapter provides an introduction to the TYAN TS65A-B8036 barebones and standard parts list, describes the external components, gives an overview of the product from different angles.
Page 6
Safety and Compliance Information Before installing and using TYAN TS65A-B8036, take note of the following precautions: ·Read all instructions carefully. ·Do not place the unit on an unstable surface, cart, or stand. ·Do not block the slots and opening on the unit, which are provided for ventilation.
Page 7
Safety Information Retain and follow all product safety and operating instructions provided with your equipment. In the event of a conflict between the instructions in this guide and the instructions in equipment documentation, follow the guidelines in the equipment documentation. Observe all warnings on the product and in the operating instructions.
Page 8
· Make sure that the area in which you install the system is properly ventilated and climate-controlled. · Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the electrical rating label of the equipment.
Page 9
rack. · Make sure the leveling jacks are extended to the floor. · Make sure the full weight of the rack rests on the leveling jacks. · Always load the rack from the bottom up. Load the heaviest component in the rack first.
Page 10
· In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you do not ground the Green/Yellow tab, it can cause an electrical shock due to high leakage currents. · Do not place objects on AC power cords or cables. Arrange them so that no one might accidentally step on or trip over them.
Page 11
Equipment Repairs and Servicing · The installation of internal options and routine maintenance and service of this product should be performed by trained service technicians/personnel who are knowledgeable about the procedures, precautions, and hazards associated with equipment containing hazardous energy levels. ·...
Table of Contents Chapter 1: Overview ................ 15 About the TYAN TS65A-B8036 ..........15 Product Model ................ 15 Features.................. 16 Standard Parts List ..............24 1.4.1 Box Contents ..............24 1.4.2 Accessories ..............25 About the Product ..............26 1.5.1 System Front View ............
Page 13
Replacing the Front Panel Board ........... 65 3.5.1 Front Panel Board Specifications ........67 Replacing the USB Board ............68 3.6.1 USB Board Specifications ..........70 Replacing the System Fan ............. 71 Replacing the HDD Backplane Board ........72 3.8.1 HDD Backplane Board Features ........
PCI-E bus implementation. The TS65A-B8036 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage. ® TYAN also offers the TS65A-B8036 in a version that can support up to twenty hot-swap 2.5” SATA HDD/SSD or sixteen...
Features B8036T65AV28HR-LE Specifications Form Factor 2U Rackmount Chassis Model TS65A Dimension (D x W x 25.59" x 17.32" x 3.43" (650 x 440 x 87mm) System Motherboard Name S8036GM2NE-LE Gross Weight 30 kg (66 lbs) Net weight 19 kg (42 lbs) Buttons (1) RST, (1) ID, (1) PWR w/ LED Front Panel...
Page 17
Processor Configurable Thermal Design Power (cTDP) Max up to 225W Wattage Supported DIMM (16) DIMM slots DDR4 ECC RDIMM/RDIMM DIMM Type / Speed 3DS/LRDIMM/LRDIMM 3DS 3200 Memory Up to 1,024GB RDIMM, 4,096GB Capacity LRDIMM 3DS Memory channel 8 Channels per CPU Memory voltage 1.2V (2) PCI-E Gen4 x8 slots (HH, HL w/...
Page 18
Connector type D-Sub 15-pin Graphic Resolution Up to 1920x1200 Chipset Aspeed AST2500 (2) USB3.1 Gen1 ports (@ rear), (2) USB3.1 Gen1 ports (via Cable), (1) USB3.1 Gen1 port (Type-A) (1) DB-9 port (COM1) + (1) header I/O Ports (COM2) (1) D-Sub 15-pin port (2) GbE ports, (1) dedicated GbE for RJ-45 IPMI...
Page 19
10° C ~ 35° C (50° F~ 95° F) Non-operating Temp. - 40° C ~ 70° C (-40° F ~ 158° F) Operating Environment In/Non-operating 90%, non-condensing at 35° C Humidity RoHS RoHS 6/6 Compliant Barebone (1) TS65A-B8036 Barebone Package Contains Manual (1) Quick Installation Guide http://www.tyan.com...
Page 20
B8036T65AV12E16HR Specifications Form Factor 2U Rackmount Chassis Model TS65A 25.59" x 17.32" x 3.43" (650 x 440 x Dimension (D x W x H) 87mm) System Motherboard Name S8036GM2NE Gross Weight 30 kg (66 lbs) Net weight 19 kg (42 lbs) Buttons (1) RST, (1) ID, (1) PWR w/ LED Front Panel...
Page 21
Design Power (cTDP) Wattage Supported DIMM (16) DIMM slots DDR4 ECC RDIMM/RDIMM DIMM Type / Speed 3DS/LRDIMM/LRDIMM 3DS 3200 Memory Up to 1,024GB RDIMM, 4,096GB Capacity LRDIMM 3DS Memory channel 8 Channels per CPU Memory voltage 1.2V (2) PCI-E Gen4 x8 slots (HH, HL w/ PCI-E tall bracket), (4) PCI-E Gen4 x8 slots (FH, HL)
Page 22
USB3.1 Gen1 ports (via Cable), (1) USB3.1 Gen1 port (Type-A) (1) DB-9 port (COM1) + (1) header (COM2) (1) D-Sub 15-pin port (2) GbE ports, (1) dedicated GbE for RJ-45 IPMI Please refer to our TPM supported TPM (Optional) TPM Support list.
Page 23
In/Non-operating 90%, non-condensing at 35° C Humidity RoHS RoHS 6/6 Compliant Barebone (1) TS65A-B8036 Barebone Package Contains Manual (1) Quick Installation Guide NOTE: 1. The specifications are subject to change without prior notice. 2. Please visit our website for the latest specifications.
Standard Parts List This section describes TS65A-B8036 package contents and accessories. Open the box carefully and ensure that all components are present and undamaged. The product should arrive with packaged as illustrated below. 1.4.1 Box Contents If any items are missing or appear damaged, contact your retailer or browse to TYAN’s website for service:...
1.4.2 Accessories If any items are missing or appear damaged, contact your retailer or browse to TYAN’s website for service: http://www.tyan.com (1) Rail kit and screws (2) Power Wire Mount (2) CPU Heatsink (2) US power cord ...
About the Product The following views show you the product. 1.5.1 System Front View M1718T65-FPB Front Panel Board/ M1717T65-USB USB Board LAN1LED ID Button LAN2 LED Power Button with green LED ID LED USB 3.1 Port Warning LED USB 3.1 Port HDD LED 3.5”...
Page 27
M1718T65-FPB Front Panel LED Control Board Switch and LED Indication Field Color Behavior System Power off / off Power Green System Power On / solid on System under S1 or S3 / Blinking (TBD) Offline / LED Off LAN1/LAN2 Green Linking / Solid on Access / Blinking Normal / Off...
1.5.2 System Rear View PSU1 HDD0 PSU0 HDD1 Serial Port (COM1)USB3.1 Ports Dedicate to IPMI Port (LAN3) VGA Port RJ45 LAN Port (LAN2/LAN1) Add-On Card field Dedicate to OCP Card Add-On Card field ID Button ID LED (Blue) ID LED State Color Description...
Page 29
Rear I/O: Onboard LAN LED Color Definition The three (3) onboard Ethernet ports have green and amber LEDs to indicate LAN status. The chart below illustrates the different LED states. 10/100/1000 Mbps LAN Link/Activity LED Scheme Left LED Right LED Link Green 10 Mbps...
Chapter 2: Setting Up 2.0.1 Before you Begin This chapter explains how to install the CPUs, CPU heatsinks, memory modules, and hard drives. Instructions on inserting add on cards are also given. 2.0.2 Work Area Make sure you have a stable, clean working environment. Dust and dirt can get into components and cause malfunctions.
Working on a system that is connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to TS65A-B8036 or injury to yourself. Ground yourself properly before removing the top cover of the system.
This section describes how to install components on to the mainboard, including CPUs, memory modules and add on cards. 2.1.1 Removing the Chassis Cover Follow these instructions to remove TS65A-B8036 chassis cover. 1. Release the latch on the left side. 2. Slide to lift the rear top cover up. http://www.tyan.com...
Page 37
S8036GM2NE-LE This picture is representative of the latest board revision available at the time of publishing. The board you receive may not look exactly like the above picture. http://www.tyan.com...
2.1.6 Board Parts, Jumpers and Connectors This diagram is representative of the latest board revision available at the time of publishing. The board you receive may not look exactly like the above diagram. The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population guidelines shown later in the manual.
Page 41
Motherboard Components Connectors 24. PCIE 74P SLIMSAS Connector (SLIMSAS 7 1. Dedicated IPMI port+USB3.0 x 2(LAN1) without in LE-sku) 25. PCIE 74P SLIMSAS Connector (SLIMSAS 5 2. CPU SMBUS Header (HDR_2) without in LE-sku) 26. PCIE 74P SLIMSAS Connector (SLIMSAS 4 3.
Page 42
PCIE3.0 Slot x24 (PESLOT2) OCP B Slot (OCP1_A) LEDs i PSU_ALERT_N LED (PSMI_LED1) vi BMC Heartbeat LED (BMC_HBLED) ii PWR_GOOD_LED (LED5) vii NGFF1_LED(LED_M1) iii RESET_LED_LED (LED7) viii NGFF2_LED(LED_M2) iv P0_PROCHOT_ LED (LED4) ix Onboard BMC IPMI ALERT LED (IPMI__LED2) v Rear ID LED (ID_LED2) x HDD_ACT_LED (HDD_LED3) NOTE: 1.
2.1.7 Installing the CPU and Heatsink Follow the steps below on installing CPUs and CPU heat sinks. Use a T20 Torx screwdriver to loosen the screws securing the force frame in a sequential order (3->2->1). Note: The force frame will automatically eject after the captive screws are being released.
Page 44
Using your thumbs and forefinger, remove the PnP cap by lifting it up vertically. Align and install the carrier frame with package into the slot on the rail frame. Note: During installation, observe the following: NOTE: During installation, observe the following: 1.
Page 45
6. Carefully close the rail frame with the installed package. Then push both edges of the rail frame firmly until it locks in place. 7. Close the force frame. Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order (1 ->2->3).
2.1.8 Installing the PCI-E Card Follow these instructions to install the PCI-E card. 1. Unscrew the riser card bracket. 2. Remove the riser card bracket from the chassis. http://www.tyan.com...
Page 47
3. Unscrew to remove the dummy brackets. 4. Insert the PCI-E card into the riser card bracket and screw it firmly. Follow the same procedures to insert the card to the other side of the riser card bracket if necessary. http://www.tyan.com...
Page 48
5. The same procedure to install the PCIE card to the second riser card. 6. Reposition and screw the riser card bracket into the chassis. http://www.tyan.com...
2.1.9 Installing the Memory Follow these instructions to install the memory modules onto the motherboard. 1. Press the memory slot locking levers in the direction of the arrows as shown in the following illustration. 2. Align the memory module with the slot. When inserted properly, the memory slot locking levers lock automatically onto the indentations at the ends of the module.
Page 50
Memory Population table http://www.tyan.com...
2.1.10 Installing Hard Drives The TS65A-B8036 supports twenty-six 2.5” hot-swap HDD/NVMe SSDs and two 2.5” hot-swap SSDs. Installing 2.5” Hot-Swap Hard Drives Follow these instructions to install a 2.5” HDD. Warning!!! Always install the hard disk drive to the chassis after the chassis has been secured on the rack.
Page 52
Open the lock to place the 2.5” hard disk drive into the HDD tray. Lock the tray lever to secure HDD. Reinsert the HDD tray into the chassis. Push to secure the locking lever until it clicks into place. http://www.tyan.com...
Page 53
Installing 2.5” Hot-Swap Hard Drives Follow these instructions to install a 2.5” SSD/HDD. Warning!!! Always install the hard disk drive to the chassis after the chassis has been secured on the rack. Press the locking lever latch and pull the locking lever open. Open the lock to place a 2.5”...
Page 54
Reinsert the HDD tray into the chassis. Push to secure the locking lever until it clicks into place. http://www.tyan.com...
19" rack. NOTE: Before mounting the TYAN TS65A-B8036 in a rack, ensure that all internal components have been installed and that the unit has been fully tested. However, to make the installation easier, we suggest that you remove all HDD trays before you insert the chassis into the rack.
Page 56
Installing the Inner Rails to the Chassis Draw out the inner rail from the rail assembly. When the rail comes to a stop pull the tab to release the latch and completely draw the inner rail out. Align the inner sliding rail on the side of the server, and pull towards the arrow to secure the hooks http://www.tyan.com...
Page 57
Repeat steps 2 to 4 to secure the sliding rail to the other side of the server. Installing the Outer Rails to the Unit Secure the outer rails to the rack on each side. Rack Mounting the Server Draw out the middle rail to the latch position. http://www.tyan.com...
Page 58
When the inner rails come to a stop, pull the tab to release the latch and push the whole system in. Secure the mounting ears of the unit to the rack using two M5 x 20L screws (A). http://www.tyan.com...
Chapter 3: Replacing Pre-Installed Components Introduction This chapter explains how to replace the pre-installed components, including the Motherboard, M1717T65-FPB Front Panel Board, M1718T65-USB Board, M1295T65-BP12-8/ M1296T65-BP12E-8 HDD Backplane, M1298T65-BP12-2 Power Distribution board, HDD Backplane, M7100F48B-PDB M7063F86-PBP Power Backplane Board. M8036-L24-3F M8036-R24-3F Riser cards, System fan and Power supply unit etc.
Removing the Cover Before replacing any parts you must remove the chassis cover first. Follow Chapter 2.1.1 to remove the cover of the TS65A-B8036. Replacing Motherboard Components Follow these instructions to replace motherboard components, including the motherboard. 3.4.1 Replacing the Riser Card...
Page 62
Unscrew the M8036-L24-3F riser card to replace with a new one. Unscrew the M8036-R24-3F riser card to replace with a new one. Follow the steps described earlier in reverse to reinstall the riser card bracket. http://www.tyan.com...
Replacing the Front Panel Board Follow these instructions to replace the M1718T65-FPB Front Panel Board. 1 Unscrew to release the Front Panel Board cover. 2 Remove the Front Panel Board cover. http://www.tyan.com...
Page 66
3 Unscrew the Front Panel Board to replace a new one. 4 Disconnect the Front Panel Board to replace a new one. 5 Follow the steps described earlier in reverse to reinstall the Front Panel Board. http://www.tyan.com...
3.5.1 Front Panel Board Specifications M1718T65-FPB Front Panel Board PCB Dimensions: 40.00*18.00*1.6mm Form Factor Thickness: 1.6mm Layer: 4 layers power button with LED reset button ID button Specifications LED: LAN1 LED (green), LAN2 LED (green), ID LED (blue), HDD LED (green/Red), FAULT LED (Red/green/Blue), Power LED http://www.tyan.com...
Replacing the USB Board Follow these instructions to replace the M1717T65-USB Board. 1 Unscrew to release the USB front cover. 2 Remove the USB front cover. http://www.tyan.com...
Page 69
3 Unscrew the USB Board. 4 Disconnect the USB Board to replace a new one. 5 Follow the steps described earlier in reverse to reinstall the USB Board. http://www.tyan.com...
Replacing the System Fan Follow these instructions to replace the fan. Take out the fan from the chassis. Replace a new fan to the chassis. Reinstall a new fan to the chassis. http://www.tyan.com...
Replacing the HDD Backplane Board NOTE: Before detach the HDD backplane, please remove all the HDD trays with HDDs, otherwise the HDD backplane will be damage when strains at the disassembly. Disconnect all cables connected to the M1295T65-BP12-8/ M1296T65-BP12E-8 HDD backplane Board. Unscrew the HDD BP Board.
PCB Dimensions: 131mm*76mm*3mm Form Factor Thickness: 3mm Layer: 6 layers 10-Pin FAN Header x 1 Specifications Mini SAS HD Connector x 2 (Input) Overview 5-Pin SGPIO Header x 1 SATA/SAS HDD x 8 (Output) 3.8.2 Connector Definition Location Definition HDD0 SATA Connector HDD1 SATA Connector...
Page 75
Front View M1296T65-BP12E-8 Rear View PCB Dimensions: 131mm*76mm*3mm Form Factor Thickness: 3mm Layer: 8 layers 10 Pin FAN Header x 1 SlimSAS Connector x4 Input Specifications 5Pin SGPIO Header x 2 Overview NVMe HDD x 8 (Output) Smbus Header x1 (HDR_1) FAN Connector x 3 http://www.tyan.com...
Replacing the Power Distribution Board Follow these instructions to replace the M7100F48B-PDB Power Distribution Board in your system. Disconnect all cables connected to the power distribution board. Unscrew to take off the power distribution board and replace with a new one. Insert the PDB into the chassis following the above procedures in reverse.
3.9.1 Power Distribution Board Features M7100F48B-PDB Power Distribution Board Board Size 82mm x 127.3mm, 6-layer PCB (3) 8-pin power connector (3) 4-pin power connector (2) 20-pin power connector Integrated I/O (1) 24-pin power connector (1) PSMI connector (1) 50-pin golden finger http://www.tyan.com...
3.10 Replacing the Power Backplane Board Follow these instructions to replace the M7063F86-PBP Power Backplane Board. Unscrew the Power BP Board bracket from the chassis. Remove the bracket beside and release the power distribution tray. Slide to take out the power backplane board tray. http://www.tyan.com...
Page 81
Unscrew to replace with a new power backplane board. Follow the steps described earlier in reverse order to reinstall the power backplane board tray into the chassis. http://www.tyan.com...
3.11 Replacing the Rear HDD Backplane Board Follow the instructions to replace the M1298T65-BP12-2 HDD backplane Board Disconnect all cables and unscrew the power distribution board. http://www.tyan.com...
3.11.1 HDD Backplane Features Front View Rear View 76mm*33.5mm*3mm Dimensions: Thickness: Layer: 8 layers Slimsas Connector (J1) SATA + NVMe Connector(NVME0) SATA + NVMe Connector(NVME1) Integrated I/O SATA Connector(SATA0) SATA Connector(SATA1) 4P Power CON (PW1) Header for PCA9544 SMBUS address Select (3PHD-1) The rear 2 SATA SSDs/HDDs (SATA0 &...
3.11.2 HDD LED Definition Color State Description NVME/SATA/SAS HDD fail HDD fail LED No failure found NVME/SATA/SAS HDD ready Green HDD Power/Access Blinking NVME/SATA/SAS HDD access activity Power disconnected http://www.tyan.com...
3.12 Replacing the Power Supply Follow these instructions to replace the power supply module in your system. Press the latch to pull the power supply out. After replacing a new power supply, press and hold the latch to push the power supply back into the chassis.
3.13.1 Removing the Motherboard After removing all of the aforementioned cables, follow the instructions below to remove the motherboard from the chassis. Remove the air duct, processor and heatsink if installed. Remove nine screws securing the motherboard to the chassis. Carefully lift the motherboard from the chassis.
Appendix I: Installing IO Plate for OCP Card Follow these instructions to install the IO Plate for OCP Card. Here shows how to install the IO Plate for the dual-port LAN card M7062-I599-2T. Unscrew the riser card bracket. Remove the riser card bracket from the chassis. http://www.tyan.com...
Page 90
3. Use a screwdriver to break the semi-shearing for the OCP card slot. Discharge the metal slug. 4. Take out the IO plate for LAN card. Use a screwdriver to break the LAN port’s semi shearing. Break one semi-shearing if a single-port LAN card is installed. Break both for a dual-port LAN card.
Page 91
5. Insert the IO Plate to the OCP card LAN port. 6. Screw the IO Plate to the chassis http://www.tyan.com...
Page 92
7. Insert the LAN card into the OCP slot 8. Secure the LAN card to the chassis http://www.tyan.com...
Appendix II: Cable Connection Tables SlimSAS 8I Cable B8036T65AV12E16HR SKU Front Backplane (BP) Board to S8036MB HDD BP 1 Cable Connect to S8036GM2NE/MB M1296T65A-BPE-8 SlimSAS 8I to SlimSAS 8I SLIMSAS1 SLIMSAS1 SlimSAS 8I to SlimSAS 8I SLIMSAS2 SLIMSAS3 ...
Page 94
Front Backplane (BP) Board to S8036MB HDD BP 3 Cable Connect to S8036GM2NE-LE/MB M1295T65A-BP12-8 Mini-SAS 1 Not connected Mini-SAS 2 Front Backplane (BP) Board to S8036MB Front HDD BP Cable Connect to S8036GM2NE/MB M1298T65-BP12E-2 SATADOM1 SATA 7P to SATA 7P SATA0 ...
Page 95
Power Supply Cables S8036GM2NE/MB M7100F48B-PDB Connect to S8036GM2NE-LE/MB PSMI HD1 Power Supply Cables M7100F48B-PDB Connect to HDD BP M1297T65-BP12E-12 PW1, PW2 Power Supply Cables Front HDD BP M7100F48B-PDB Connect to M1298T65-BP12E-2 Power Supply Cables Rear HDD BP M7100F48B-PDB Connect to...
Appendix III: Fan and Temp Sensors This section aims to help readers identify the locations of some specific FAN and Temp Sensors on the motherboard. A table of BIOS Temp sensor name explanation is also included for readers’ reference. NOTE: The red dot indicates the sensor.
Page 97
BIOS Temp Sensor Name Explanation: http://www.tyan.com...
Page 98
CPU_Tct1_Value Temperature of the CPU_Tct1 MB_Air_Inlet Temperature of the MB_Air_Inlet Area SAS_Air_Outlet Temperature of the SAS_Air_Outlet Area SAS_Air_Inlet Temperature of the SAS_Air_Inlet Area CPU_CORE_MOSFET Temperature of the CPU_ CORE_MOSFET CPU_SOC_MOSFET Temperature of the CPU_ SOC_MOSFET DIMM_MOSFET_1 Temperature of the DIMM MOSFET_1 DIMM_MOSFET_2 Temperature of the DIMM MOSFET_2 P0_D1_UMC0_CH_A...
Page 99
SYS_FAN_1 Fan speed of SYS_FAN_1 SYS_FAN_2 Fan speed of SYS_FAN_2 SYS_FAN_3 Fan speed of SYS_FAN_3 SYS_FAN_4 Fan speed of SYS_FAN_4 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6 SYS_FAN_7 Fan speed of SYS_FAN_7 SYS_FAN_8 Fan speed of SYS_FAN_8 SYS_FAN_9 Fan speed of SYS_FAN_9 SYS_FAN_10...
Appendix IV: FRU Parts Table TS65A-B8036 FRU Parts Item Model Number Part Number Picture Description Power FRU-PS-0320 471100000417 1200 W,CHICONY Supply FRU-TH-0270 336210000065 22000RPM,40*40*28MM Heatsink FRU-TH-0310 343T60900003 Heatsink Air duct FRU-TA-0180 344T60900011 Air duct FRU-RC-1000 5411T6090008 M8036-L24-3F Riser Card PCBA...
Appendix V: Technical Support If a problem arises with your system, you should first turn to your dealer for direct support. Your system has most likely been configured or designed by them and they should have the best idea of what hardware and software your system contains. Hence, they should be of the most assistance for you.
Page 102
The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid. TYAN will pay to have the board shipped back to you. ® TS65A-B8036 Service Engineer’s Manual V1.0 TYAN D2480 - 100 Document No.:...