Remote Installation - Vermont Castings SA18SHKRN Installation And Operating Instructions Manual

Vented gas log sets - remote hearth kits
Table of Contents

Advertisement

Create a mixture of equal parts soap and water. Apply to all the joints of the pipe fittings from the gas sup-
ply pipe to the burner. Turn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear
in the soap solution applied to the joints, there is a leak. Turn off the gas supply valve and tighten those
fittings. Repeat the above procedure until no bubbles appear in the soap solution. Remember to test all
joints.
WARNING: DO NOT USE AN OPEN FLAME TO TEST FOR LEAKS!
NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the gas
supply line.
Connect remote (GWSK or MRC 1, 2, 3) wires to
ON/OFF/RS switch. (Fig. 8) If the MRC (remote) is
used, the receiver can be placed to the front right
of the gas valve to ensure safe operation.
8
Leak Test Procedures

Remote Installation

Figure 8
TH
TP
TH/TP
Lg188
AGa pilot wiring
3311857
LG188