Installation distance with brick / firewall
(Norwegian firewall is for example a 100 mm thick brick wall or 50 mm thick firewall
plate against a flammable wall).
Recommended min. convection area
800cm² above the stove. (may be
distributed over several apertures)
C
Distance to flammable
items Min. 387mm
Distance to firewall 0mm
(10mm recommended)
Distance to flammable
items Min. 300mm
If insufficient convection is created, damage may be caused to the brick walls.
RAIS/
B
B
Recommended min. convection area
490cm² under the stove. (may be
distributed over several apertures)
Distance to firewall 0mm
(10mm recommended)
C-C
attika
- User manual for RAIS 2-1
Distance to furniture (A): min. 600mm
to guide the hot air out
of the convection grilles,
we recommend fitting a
non-flammable plate just
above the grates.
C
A
B-B
A
15