Operating instructions
- EC Declaration of Conformity
pure STERIBASE 300

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STERIBASE 300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PURE STERIBASE 300

  • Page 1 Operating instructions - EC Declaration of Conformity pure STERIBASE 300...
  • Page 3 Operating instructions Translation of the original operating instructions pure STERIBASE 300 100003739 1025009-00 / en / 07.2020...
  • Page 4: Legal Notice

    Fax: +49 (0) 22 24 / 818-615 authorization or disclosed to other E-mail: parties. info@pure-lufthygiene.de The right to make technical changes in regard to the fig- www.pure-lufthygiene.de ures and information contained in these operating instruc- tions is reserved! 2/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 5: Table Of Contents

    Table of contents Table of contents Legal notice....... . . 2 General information .
  • Page 6: General Information

    Authorized, trained and qualified personnel Qualified staff from an external company who have been trained and authorized by the manufacturer to undertake assembly and maintenance work on specific equipment. 4/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 7: Safety Instructions

    General information Safety instructions CAUTION! To protect the device from unauthorised opening DANGER! and to secure the guarantee claims, all brackets Personal danger due to electric shock or must be sealed! burns! Assembly and electrical connection must comply CAUTION! with the national regulations. Using unsuitable lamps can eliminate the The upgrading, maintenance or repair of the de- effectiveness of the device and void the CE...
  • Page 8 – A socket with earthing contact must be provided by the customer near to the device. – The installation location must be selected so that de- germed air can equally flow through the room. 6/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 9: Warning Label

    General information Warning label What to do if one of the fluorescent lamps breaks? The warning label is located on the device near to the On / Off switch. Note: Fluorescent lamps contain mercury. Note: The quantity of mercury released when a fluo- rescent lamp breaks is too low in general to pose a threat to health.
  • Page 10: Location Of The Type Plate

    If the device has been transported or stored at 100001429 low temperatures, please wait until the device has adjusted to the temperature in the room be- 40324 / 1 40324 / 2 fore putting it into operation. 8/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 11: Cleaning

    General information Cleaning Maintenance Cleaning the device – The inside of the device may not be cleaned as com- ponents may be damaged. – If desired, the outside of the device can be wiped with a damp cloth (where necessary with a mild cleaning agent).
  • Page 12: Directives

    The respective national laws apply. Please contact your local dealer. 10/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 13: Warranty And Liability Exclusions

    General information Warranty and liability exclusions Warranty and liability claims for personal injury and prop- erty damage are excluded if they are the result of one or more of the following causes: • improper use of the device; • improper assembly, commissioning, operation or maintenance of the device;...
  • Page 14: Description

    Description Description Scope of delivery 40326 / 4 Scope of delivery: 100003739-.. pure STERIBASE 300 1024949.. Operating instructions 1503309-.. Mains power cable (2.5 m) 1007345-.. Service booklet 100 5911-.. 2x UV-C lamps B 12/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 15: Description Of Device

    Description Description of device Steritube basic 100001429 2020 2021 2022 2023 2024 40365 / 4 1. Lightlock, UV-C light shield and air outlet 2. Control panel 3. STERITUBE PLUS with 2 UV-C lamps 4. Pedestal with fan 5. Air inlet filter, three-part 6.
  • Page 16: Installation And Operation

    40372 / 1 40372 / 2 The cardboard box has been provided with a label where information such as the model type and device no. (a) can be found. 1) In Germany: VDE regulations 14/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 17: Setting Up The Floor-Standing Device

    Installation and operation Setting up the floor-standing device Note: Please observe the notes on installation and operation on p. 6. 40329 / 1 40558 / 0 40559 / 0 ca. 45° 40563 / 0 40564 / 0 Gebrauchsanweisung - 15/24...
  • Page 18 Setting up the floor-standing device Note: If the mains switch is switched on, the device starts with the lamps switched off (Position "0"). 230 - 240 V 40350 / 1 230 - 240 V 40368 / 0 16/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 19: Moving The Floor-Standing Device

    Installation and operation Moving the floor-standing device Note: Please observe the notes on installation and operation on p. 6. 230 - 240 V 40562 / 0 40558 / 0 40559 / 0 ca. 45° 40563 / 0 40564 / 0 Gebrauchsanweisung - 17/24...
  • Page 20 Installation and operation Moving the floor-standing device 230 - 240 V 40350 / 1 18/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 21: Switching The Device Off

    If the mains switch is switched on, the de- vice starts with the lamps switched off (Po- sition "0"). 230 - 240 V 40368 / 0 Switching the device off 230 - 240 V 40354 / 1 19/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 22: Operation

    Installation and operation Operation Faults A fault is indicated by a red LED on the control panel. Overview of the control panel – Switch the device off. – Rectify the fault if possible (e.g., clean the filter, clear any covered openings, check the mains plug and On/ Off switch).
  • Page 23: Cleaning The Filter

    Installation and operation Cleaning the filter The cleaning intervals are highly dependent on the oper- ating conditions. – Check the filter on the inside and outside as well as the protective grille behind the filters for visible soiling on a regular basis.
  • Page 24: Technical Data

    The following countries require a type F to type G adapter: United Kingdom: 2 flat contacts and 1 rectangular contact (type G) with 6.3 A micro-fuse Austria, the Netherlands: no adapter required (type F) France, Belgium: no adapter required (type E) 22/24 - pure STERIBASE 300 1025009-00 07/2020...
  • Page 25: Other Technical Data

    Technical Data Other technical data Weight: Approximately 40 kg (including UV-C lamps) Air volume Level 1: 150 m³/h : Level 2: 230 m³/h : Level 3: 300 m³/h : Sound pressure level measurement (L pA ) Level 1: 29.4 dB(A) Level 2: 40.5 dB(A) Level 3: 47.2 dB(A) Sound power measurement (L wA )
  • Page 26: Ec Declaration Of Conformity

    EC Declaration of Conformity EC Declaration of Conformity 24/24 - pure STERIBASE 300 1025009-00 07/2020...