KV-XR29M80
RM-W104
2. DISPLAY OF STANDBY/(1) indicator FLASH
COUNT
Lamp ON 300ms
Lamp OFF 300ms
3. STOPPING THE STANDBY/(1) indicator FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/(1) lamp
from flashing.
4. SELF-DIAGNOSTIC SCREEN DISPLAY
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confirmed,
it is possible to bring up past occurrence of failure on the screen for confirmation.
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
[display] / channel [5] / volume [-] / Power
Self-Diagnostic screen display
SELF DIAGNOSTIC
2 :
0
3 :
N/A
4 :
0
5 :
1
8 :
0
101 :
N/A
Lamp OFF 3 sec
˘
Note that this differs from entering the service mode (volume [+]).
Numeral "0" means that no fault was detected.
Numeral "1" means the number of a fault occurrence (1~255).
Diagnosis Item
+B overcurrent
I-Prot
IK (AKB)
HV Protect
* One flash count is not used for self-diagnosis.
FLASH RED n Please refer diagnosis item.
FLASH GREEN n OK
/ TV
– 4 –
Flash Count*
2 times
4 times
5 times
8 times
STANDBY indicator