NOTICE

– this is not an error
Code Name
CP
Cold air blowing protection
H1
Defrosting

ODU GENERAL ERROR

Code Name
E1
Compressor high-pressure protection
E5
Compressor or system overload protection
P5
Compressor overcurrent protection
P7
Drive unit module sensor malfunction
PL
DC bus low voltage protection
PH
DC bus high voltage protection
C6
No ground wire
CC
Wrong wall-mounted controller
EE
ODU memory chip malfunction
H5
IPM protection
Drive module (control board) desynchronization
H7
protection
Hc
PFC protection
Evaporator temperature is higher than 58°C
Hp
(Heating mode)
Lc
Startup malfunction
Lp
The indoor unit and outdoor unit do not match
U1
Compressor phase current detection circuit failure
U3
Voltage drop on DC bus

LIMITATION

Code Name
F6
Condenser overheat protection
F8
Compressor overcurrent protection
Compressor discharge high-temperature
F9
protection
P5
Compressor overcurrent protection
FH
Evaporator freezing protection
Frequency limit due to the high temperature of
EU
the module
IDU heat exchanger overheat protection (in
H0
Heating mode)
Sinclair alarm interface unit SAI-01
Table 8: ODU general error
Note
Does not appear on the IDU display
Does not appear on the IDU display
Does not appear on the IDU display
The error will only appear on the IDU
display if it occurs 5 times.
Does not appear on the IDU display
Does not appear on the IDU display
Does not appear on the IDU display
Table 9: Limitations
Note
not displayed
not displayed
Note
The error will only appear on the IDU
display if it occurs 5 times.
The error appears on the IDU display; if
it occurs 6 times, the A/C is shut down.
12