  • Page 1 Shenchen Peristaltic Pump Manual of V6-12L Series...
  • Page 2 Important Information  Please read the manual carefully before operating the product. Warning  Tubing may have crack due to wear. It results in the overflow of fluid from tubing. In that time human body and instruments may be damaged. So user must check usually and change tubing in time. ...
  • Page 3 V6-12L Series Product Appearance..........- 1 - V6-12LSeries Keyboard Instruction..........- 2 - V6-12L Series Operation Interface Structure:......- 3 - V6-12L Series Operation Interface Instruction......- 3 - V6-12L Series Technical Specification........- 16 - V6-12L Series Function and Features........- 16 - External Control Interface Instruction:........- 18 -...
  • Page 4 Shenchen Peristaltic Pump V6-12L Series V6-12L Series Product Introduction: 4.3 inch color touch screen control; dynamic display working status; flow data, setted parameters and system settings displays in the same screen. Intelligent calibration and online micro adjusting function; three measurement mode; fixed volume measurement, fixed time and volume, timer start and stop.
  • Page 5 Shenchen Peristaltic Pump V6-12L Series V6-12LSeries Keyboard Instruction Stop Button:Press stop button, stop working. Forbidden buttons can be used on the main interface. Full Button:When stop state or transferring state, press this button, the pump will running with highest speed. This button can be used for wash tube or fast filling liquid.
  • Page 6 Shenchen Peristaltic Pump V6-12L Series V6-12L Series Operation Interface Structure: V6-12L Series Operation Interface Instruction 1. Boot Interface: After power on the system, enter the welcome interface, choose system language, Chinese/English. If do not choose, it will enter the English main interface after 2.5 seconds automatically.
  • Page 7 Shenchen Peristaltic Pump V6-12L Series Speed/Flow Rate Display: Under the flow rate mode, display the current set up flow rate, the motor speed display at the C frame. Under the rotating speed mode, display the current set up speed, flow rate display at the C frame.
  • Page 8 Shenchen Peristaltic Pump V6-12L Series Numeric keypad input interface as below: Input Information Display : The information displayed is the current operation object. Input Data Display: Display the current input data, range is 0.01-9999. Unit Display: Display input units when input flow rate or volume.
  • Page 9 Shenchen Peristaltic Pump V6-12L Series Click the pump head and tubing size to choose the pump head and tubing. Reference flow rate display the max. and min. flow rate with the current pump head and tubing. Click the flow rate mode or rotating speed mode button to choose the working mode.
  • Page 10 Shenchen Peristaltic Pump V6-12L Series Click the Setting button in the main interface, then click Suck-Back button to enter the back suction angle setting interface. Click angle button, enter suck-back angle then click ENT. This can set all suck-back angle when motor stop running, except dispensing is ON.
  • Page 11 Shenchen Peristaltic Pump V6-12L Series Click Setting button in the main interface, then click Communication button to enter Communications Settings interface. This pump support MODBUS--RTU Mode. Please select baud rates communication interface (RS485/RS232). Click Slave No. button to enter peristaltic pump address No.(range:1-32 ), select communication enable is ON.
  • Page 12 Shenchen Peristaltic Pump V6-12L Series time and volume. Others display transferring mode. If fixed time and volume turn on, the target volume and running time is set up parameter, unable to amend. Other modes, the running time is 60s, you can click the run time button to amend the running time.
  • Page 13 Shenchen Peristaltic Pump V6-12L Series ①.Click the Calibration button from the main interface, enter the flow rate calibration interface. ②. Now only the Add, Dec and Esc button is usable, other buttons are forbidden. ③. Click Add or Dec button to adjust the flow rate or volume.
  • Page 14 Shenchen Peristaltic Pump V6-12L Series After turn on this function, the peristaltic pump will measure the volume automatically, when the volume reach set up volume, the pump will stop working automatically. The flow rate can be changed during the pump working.
  • Page 15 Shenchen Peristaltic Pump V6-12L Series Start button again, start dispensing again. Click Dispensing button, set ON to turn on this function. Click Set Volume to input the volume, unit is mL. Click Suck-back Angle, input the suck-back angle, range is 0-360 ° . Click Run time, input working time. The prompting frame display the flow rate and motor speed with the set up parameters.
  • Page 16 Shenchen Peristaltic Pump V6-12L Series Main Functions Operation Process 1、Flow Rate Transferring Function Note: Flow rate calibration process please refer the flow rate calibration interface instruction. 2、Fixed Volume Measurement Function Note: Flow rate calibration process please refer the flow rate calibration interface instruction.
  • Page 17 Shenchen Peristaltic Pump V6-12L Series 3、Dispensing Note: Flow rate calibration process please refer the flow rate calibration interface instruction. 4、Timer Start And Stop Function Under the flow rate transferring mode, set the pump start at 8:30 a.m. from Monday to Friday, stop at 5:30 p.m., the process as below:...
  • Page 18 Shenchen Peristaltic Pump V6-12L Series Click Start Time, set the start time is 8:30 a.m., turn the button to ON. Click Custom, come out the repeat date window, as below: Timer stop setting process is same with the timer start.
  • Page 19 TTL level Protection rating IP31 V6-12L Series Function and Features  4.3 inch color touch screen control, dynamic display working status, the flow volume and motor speed display in the same screen.  Intelligent calibration function, it can calibrate the flow rate and dispensing volume, ensure the flow accuracy, suitable for high accuracy transferring liquid.
  • Page 20 Shenchen Peristaltic Pump V6-12L Series this process, the volume can be changed. It is suitable for laboratory liquid dosing and chemical reaction process.  Fixed time and volume function: After turn on this function, the peristaltic pump will transfer fixed volume within set time. It is Suitable for liquid dispensing in laboratory and industrial production.
  • Page 21 Shenchen Peristaltic Pump V6-12L Series External Control Interface Instruction: External control interface as below: ①. Analog signal input terminal: External control setting interface, choose the’ Analog Signal’ and turn on the ‘Ext. Speed’. Control the motor speed from 0 rpm to 600rpm through analog signal.
  • Page 22 Shenchen Peristaltic Pump V6-12L Series Internal isolation 5VDC output ②. External control start/stop, cw/ccw signal input terminal: Active signal input. If need change to 12VDC or 24VDC input, please open the controller housing, and change the jumper connection on the external control board as below : GD2: External control signal common input terminal.
  • Page 23 Shenchen Peristaltic Pump V6-12L Series active. ③. R/S 1 External control signal input terminal: Passive signal input. Pulse mode: R/S 1 short connect with GD1 and then disconnect, the pump start running. Short connect and disconnect again, the pump stop running.
  • Page 24 Shenchen Peristaltic Pump V6-12L Series ⑤. RS232 Communication : Choose RS232 in the Communication setting interface, this terminal is active. GND: Communication ground terminal. TXD: Master sending, peristaltic pump receive signal terminal. RXD: Peristaltic pump sending, master receive signal terminal.
  • Page 25 Shenchen Peristaltic Pump V6-12L Series Product Dimension (mm): - 22 -...
  • Page 26 Shenchen Peristaltic Pump V6-12L Series Maintenance When pump is not working, please loose the cartridges of pressing the tubing for avoiding changing the shape of tubing because of longtime extrusion. Keep the rollers of pump head clean and dry, otherwise it can quicken the tubing wearing, reduce the useful life of tubing and lead the rollers to damage in earlier.
  • Page 27 Shenchen Peristaltic Pump V6-12L Series Warranty and After Service Products have 1 year warranty (not including tubing). In the warranty, the products are damaged because of users’ wrong operation or other human damages, our company do not responsibility for warranty. Beyond the warranty, we only charge the cost of maintenance.
  • Page 28 MADE IN CHINA Baoding Shenchen Precision Pump Co., Ltd. Address: No. 267 KeYuan Street, MinYing Technology Park, Baoding, China. Tel: 86-312-2055881, 2031189 Fax: 86-312-2055371 Website: www.good-pump.com Email: easypump2@gmail.com easypump3@gmail.com...