Technical Service; Specifications - Vanguard VN12 Owner's Operation And Installation Manual

Vent-free natural gas heater
Table of Contents

Advertisement

TECHNICAL
SERVICE

SPECIFICATIONS

20
If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
OBSERVED
PROBLEM
Gas odor even when
control knob is in OFF
position
Gas odor during com-
bustion
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International's Technical Service Department at 1-800-323-
5190.
B.T.U. (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (inches of water)
Maximum
Minimum
Dimensions, Inches (H x W x D)
Heater
Carton
Weight (pounds)
Heater
Shipping
!
WARNING
WARNING ICON
G 001
POSSIBLE
CAUSE
1. Gas leak. See Warn-
ing statement at
top of page
2. Control valve defective
1. Foreign matter between
control
valve
and
burner
2. Gas leak. See Warn-
ing statement at
top of page
VN12
6,000/12,000
Natural Only
Piezo
3" W.C.
10.5"
4"
20 1/2 x 13 1/2 x 5
25 x 16 11/16 x 7 1/2
14
17
REMEDY
1. Locate and correct all
leaks (see CHECK-
ING GAS CONNEC-
TIONS, page 10)
2. Replace control valve
1. Take apart gas tubing
and remove foreign mat-
ter
2. Locate and correct all
leaks (see CHECKING
GAS CONNECTIONS,
page 10)
VN6A
6,000
Natural Only
Piezo
3" W.C.
10.5"
4"
20 1/2 x 13 1/2 x 5
25 x 16 11/16 x 7 1/2
13
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vn6a

Table of Contents