Technical Service; Specifications; Service Hints - Vanguard GVB50P Owner's Operation And Installation Manual

Vented propane gas heaters
Table of Contents

Advertisement

TECHNICAL
SERVICE

SPECIFICATIONS

SERVICE
HINTS
100354
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International's Technical Service Department at 1-800-323-
5190.
BTU
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure
Maximum
Minimum
Dimensions, Inches
Heater (H x W x D)
Shipping Weight (pounds)
Flue Vent Size
Orifice Size
Note:
These heaters are certified for elevations of 0-4500 feet above sea level. For
elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce yellow flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.
35,000 BTU/Hr
Model
35,000
Propane Only
Piezo
10.5" W.C.
14" W.C.
11" W.C.
1
25 x 27
/
x 16
4
78
4" dia.
52 drill, ø .0635
50,000 BTU/Hr
Model
50,000
Propane Only
Piezo
10.5" W.C.
14" W.C.
11" W.C.
1
28 x 32
/
x 16
2
98
4" dia.
46 drill, ø .081