Note: The most current version of these instructions can be found online at
Tools needed: Phillips screwdriver,
adjustable wrenches instead)
WARNING: Important! Read and understand these instructions before assembling or using the AL-82995
Overbed Table. If you do not understand any part of these instructions, contact a healthcare professional
for direction in the use of this product. If the overbed table is not properly assembled and adjusted,
personal injury and/or damage to the overbed table could result.
WARNING: If components are damaged or missing, contact your dealer immediately. DO NOT use
substitute parts.
WARNING: Notice for California Customers- California Proposition 65 WARNING: This product
contains a chemical known to the State of California to cause cancer and reproductive or
developmental harm.
WARNING: ALCO Sales & Service Co. assumes no responsibility for any damage or injury caused by
improper assembly or use of this product.
ASSEMBLY INSTRUCTIONS
Unpacking
1. Open end of box.
2. Slide contents out of box.
3. Collect base, table top, column, and hardware.
Assembly (see picture at right)
WARNING: Do not remove the black
screw
from the column
13
completely assembled and in upright position; the
table top could rise suddenly and cause serious
personal injury.
WARNING: The column is spring-loaded — DO NOT
disassemble the column; this could cause serious
personal injury.
1. Place table top
upside down on level surface.
1
2. Ensure the release rod (not shown, inside column) is fully
inside the column
, then insert the column tongue into
2
the table top bracket
and bracket holes. Insert — but do not tighten
— the two Phillips screws
through bracket into tongue.
3. Position the release lever
facing table top, and install in column. Match the release
lever and bracket alignment holes, then insert hex bolt
through both to secure release lever to bracket. Install hex
nut
on bolt. Use two M6 wrenches to tighten. Use a
4
Phillips screwdriver to now tighten the Phillips screws
that secure bracket to tongue.
4. Note orientation of base caster holes, facing away
from table top as shown, and place the base
bolt plate
, bolt sleeves
11
bolts.
5. Install the casters
8
6. TURN THE TABLE UPRIGHT and place it on the floor. Use a Phillips screwdriver to remove the black screw
discard it and replace it with the chrome screw
7. Remove protective film from table top surface.
WARNING: Ensure that the table is assembled as described, and that all components are securely
attached, before use.
AL-82995: OVERBED TABLE, STANDARD
NON-TILT ASSEMBLY & OPERATION
INSTRUCTIONS
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE
5
/
wrench, two M6 wrenches (you may wish to use appropriate socket or
8
before the table is
2
as shown at right. Align the tongue
5
and washers
as shown
6
6
as shown, with curved side
3
7
, base, and into the end of the column as shown. Use a 5 /8 wrench to tighten the
10
and
as shown: press the casters in until they lock into place.
9
11
bolt plate
10
bolt sleeve
(2 each)
2
column
3
release
lever
alignment hole
4
hex bolt
4
6
Assembly
above the column. Install the two large hex bolts
. Use a Phillips screwdriver to tighten the screw.
14
www.alcosales.com
12
large hex bolt
(2 each)
8
locking caster (2 each)
9
non-locking caster
(2 each)
7
base
chrome hex head screw —
DO NOT remove
13
black screw — DO NOT remove from column
before table is completely assembled and in
upright position
tongue
4
hex nut
6
Phillips screw
(2 each)
6
washer
(2 each)
5
bracket
1
table top
through the
12
;
13
1
Need help?
Do you have a question about the AL-82995 and is the answer not in the manual?
Questions and answers