Fan tray

Advertisement

Before you install the fan tray, install switching fabric modules or filler panels
!
in the switching fabric module slots.
To install the fan tray in slot FAN1, orient the fan tray so that the LEDs are on
the left side of the front panel. To install the fan tray in slot FAN2, orient the
fan tray so that the LEDs are on the right side of the front panel.
Wear an ESD wrist strap and make sure it makes good skin contact and is
1
reliably grounded.
2
Unpack the fan tray.
3
Orient the fan tray correctly. Align the positioning pin on the fan tray with the
positioning hole in the chassis.
4
Hold the fan tray handle and insert the fan tray into the slot. Keep the fan
tray as straight and stable as possible when inserting it into the slot.
5
Fasten the captive screws on the fan tray.
Align the positioning pin on the fan tray
with the positioning hole in the chassis
Orient the fan tray
with the LEDs on
the left for slot
Orient the fan tray with
FAN1
the LEDs on the right for
1
slot FAN2
3
2
Removing the fan tray
When you remove the fan tray, do not touch the rotating fans to avoid getting
!
injured.
Before you replace a switching fabric module, remove the fan tray.
1
Prepare an anti-static mat.
Wear an ESD wrist strap and make sure it makes good skin contact and is
2
reliably grounded.
Loosen the captive screws on the fan tray.
3
Hold the fan tray handle and pull the fan tray part way out of the chassis
4
slowly until the fan tray is disengaged from the chassis. Remove the fan tray
after the fans stop rotating.
5
Place the fan tray on the anti-static mat.
2
1