Download Print this page
HPE Apollo 8000 System Maintenance And Service Manual
HPE Apollo 8000 System Maintenance And Service Manual

HPE Apollo 8000 System Maintenance And Service Manual

Intelligent cooling distribution unit

Advertisement

Quick Links

HPE Apollo 8000 System
Maintenance and Service Guide
Abstract
This guide describes identification and maintenance procedures, diagnostic tools, specifications, and requirements for hardware
components and software. This guide is for an experienced service technician. Hewlett Packard Enterprise assumes you are qualified in the
servicing of computer equipment, trained in recognizing hazards in products, and are familiar with weight and stability precautions.
Part Number: 747363-002R
November 2015
Edition: 3

Advertisement

loading

Summary of Contents for HPE Apollo 8000 System

  • Page 1 HPE Apollo 8000 System Maintenance and Service Guide Abstract This guide describes identification and maintenance procedures, diagnostic tools, specifications, and requirements for hardware components and software. This guide is for an experienced service technician. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment, trained in recognizing hazards in products, and are familiar with weight and stability precautions.
  • Page 2: Illustrated Parts Catalog

    Illustrated parts catalog Rack components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website (http://www.hpe.com/info/partssurfer). Item Description Spare part number Customer self repair Air cooling unit assembly —...
  • Page 3: Spare Part Number

    — Water temperature sensors* — Rack controller air sensor* — PCA rack control* — HPE Apollo f8000 rack water hook-up kit* — HPE Apollo 8000 iCDU rack water — hook-up kit* Rack plumbing assembly* — Display port cable with latch*...
  • Page 4 Packard Enterprise per la sostituzione, potrebbero essere addebitate spese aggiuntive a seconda del tipo di garanzia in assistenza previsto per il prodotto. No—Alcune parti Hewlett Packard Enterprise non sono progettate la riparazione in autonomia da parte del cliente. In base a quanto previsto dalla garanzia per il cliente, Hewlett Packard Enterprise richiede l'intervento di un tecnico autorizzato per la sostituzione della parte.
  • Page 5 Power shelf components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website (http://www.hpe.com/info/partssurfer). Illustrated parts catalog 8...
  • Page 6: Customer Self Repair

    Item Description Spare part number Customer self repair Power meter — — Optional a) Power meter (on page 52) (480 VAC) 724733-001 b) Power meter (on page 52) (415 VAC) 716928-001 Optional Pass-through board (on page 51) 716930-001 Mandatory Communication board (on page 48) 716929-001 Optional Optional...
  • Page 7 Obbligatorio—Parti per le quali il cliente è tenuto a effettuare autonomamente la riparazione. Se si richiede l'intervento di Hewlett Packard Enterprise per la sostituzione di queste parti, al cliente verranno addebitate le spese di viaggio e manodopera dell'operazione. Facoltativo—Parti per le quali la riparazione in autonomia da parte del cliente è facoltativa. Queste parti sono progettate per consentire anche la riparazione da parte del cliente.
  • Page 8 Utility module products There are two utility module products that can be installed in the Apollo 8000 System. Although they might appear different and have slightly different features, their basic functionality within the Apollo 8000 System is the same. For the purpose of clarity in this document, when removing and replacing spare parts, the components will be referred to as shown in the following illustration and table.
  • Page 9 Utility module pass-through assembly — Fan switch cable — Utility module APM management 779692-001 Mandatory controller ("Utility module HPE APM management controller" on page 70) Ethernet aggregator board (on page 58) 784711-001 Mandatory Ethernet management backplane — I/O mezzanine board* —...
  • Page 10 fournisseur de services agréé de procéder au remplacement de la pièce. Ces pièces sont signaléespar le mot « Non » dans le Catalogue de pièces illustré. Obbligatorio—Parti per le quali il cliente è tenuto a effettuare autonomamente la riparazione. Se si richiede l'intervento di Hewlett Packard Enterprise per la sostituzione di queste parti, al cliente verranno addebitate le spese di viaggio e manodopera dell'operazione.
  • Page 11 Customer self repair Mandatory Utility enclosure fan module (on page 69) 805418-001 Utility module APM management 779692-001 Mandatory controller ("Utility module HPE APM management controller" on page 70) Redundant power supply (on page 38) 716932-001 Mandatory Illustrated parts catalog 14...
  • Page 12 Item Description Spare part number Customer self repair 180 Port Ethernet switch* — Ethernet Uplink module* — Ethernet aggregator board (on page 58)* — Interposer assembly* — iLO/Switch pass-through assembly* — Power pass-through board* — I/O Uplink mezzanine assembly* — Uplink pass-through board* —...
  • Page 13 Obligatorio—Componentes cuya reparación por parte del usuario es obligatoria. Si solicita a Hewlett Packard Enterprise que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio. Opcional—Componentes cuya reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario.
  • Page 14 Compute cell components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website (http://www.hpe.com/info/partssurfer). Item Description Spare part number Customer self repair Optional Power distribution module assembly (on...
  • Page 15 No—Some Hewlett Packard Enterprise parts are not designed for customer self repair. In order to satisfy the customer warranty, Hewlett Packard Enterprise requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog. Obligatoire—Pièces pour lesquelles le client doit procéder lui-même aux réparations.
  • Page 16 "No" (Não), no catálogo de peças ilustrado. Leaf switch components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website (http://www.hpe.com/info/partssurfer). Illustrated parts catalog 19...
  • Page 17 Item Description Spare part number Customer self repair Leaf switch 784713-001 Optional Interposer board 784714-001 Optional Cable cartridges and housing — Personality board 784716-001 Optional Leaf switch cables* — Optional *Not shown If the spare part number is not listed above, work with your Hewlett Packard Enterprise service representative to determine the spare part number for your product.
  • Page 18 Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website (http://www.hpe.com/info/partssurfer). The iCDU has no customer replaceable parts. However, the following spare parts are available. For service or spare part numbers, work with your Hewlett Packard Enterprise service representative.
  • Page 19 Item Description Spare part number Customer self repair Controller WEB card 138830 — PC03 controller 157879 — Relay 159663 — Water detection module 162972 — Detection water rope 162973 — Main disconnect 163807 — Valve solenoid 176359 — Solenoid coil 176360 —...
  • Page 20 Zwingend—Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den Austausch dieser Teile von Hewlett Packard Enterprisevornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt.