TEMPERED HIPSWITCH 100 Series Platform Manual

Advertisement

Quick Links

Industrial Security Appliances
TOP & FRONT PANEL LAYOUTS

MULTI-PURPOSE BUTTON

NOTE: Some Tempered Networks documents may refer to this as a "Reset" button.
The multi-purpose button provides two different functions, depending on how long it is pressed and
held.
Short Tap
Press for 3 seconds and release. The Status LED will now
blink steadily.
Long Tap
Press for at least 8 seconds and release. The Status LED
will now blink in a 2 flash, 1 flash pattern,
NOTE: To exit diagnostic mode, press the reboot button in the diagnostic interface or cycle the input
power of the HIPswitch.
DIMENSIONS

PACKAGE CONTENTS

Qty
Item
x1
HIPswitch-100
x1
DIN-rail kit (attached)
HIPswitch™-100 Series
1. Power input connector
2. SIM slot (100g only)
3. LED: Power input #1 indicator
ON = Activated
4. LED: Power input #2 indicator
ON = Activated
5. LED: PoE indicator
ON = Power supplied over Ethernet
on port 1
6. LED: Link and activity for port 1
ON = Port is linked
Blinking = Data is being transmitted
7. LED: Link and activity for port 2
ON = Port is linked
Blinking = Data is being transmitted
8. LED: Blink = Cellular modem ready
9. LED: Status (see Status Codes)
10. Multi-purpose button
(see Multi-purpose button table)
11. Ethernet port 2
12. Ethernet port 1
(optional PoE)
13. Aux. cellular antenna connector
(100g only)
14. LED: Serial receive activity (-s models only)
15. LED: Serial transmit activity (-s models only)

16. Serial connector (-s models only)

17. Main cellular antenna connector (100g only)
Places the HIPswitch
in diagnostic mode.
Resets the HIPswitch
to factory defaults.
Qty
Item
x2
Wall-mount kit
x2
4-pin terminal block
EN
DOC-0053-A
PLATFORM GUIDE
The HIPswitch™-100 Series is a small form
factor industrial grade security appliance
that facilitates private overlay networks
between customer-provided equipment and
devices. This document contains import-
ant operating information, specifications,
and installation instructions for the HIP-
switch™-100.
MODELS
Part Number
Model
101e-201
HIPswitch-100e
101g-201
HIPswitch-100g
101e-s-201
HIPswitch-100e-s
101g-s-201
HIPswitch-100g-s

Safety and Warnings

Elevated Operating Ambient: If instslled in a closed environment, make sure the
operating ambient temperature is compatible with the maximum ambient temperature
specified by the manufacturer.
Reduced Air Flow: Make sure the mount of air flow required for safe operation of the equipment
is not compromised during installation.
Mechanical Loading: Make sure the mounting of the equipment is not in a hazardous condition
due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of the circuits might have on over-current protection
and supply wiring. Appropraite considertation of equipment nameplate ratings should be used
Explosion Hazard: Do not disconnect equipment unless power has been removed or the area is
known to be non-hazardous.

WIRING

Power Inputs

This device supports dual redundant power supplies, power supply 1
(PWR 1) and power supply 2 (PWR 2). The connectors for PWR 1 and
PWR 2 are located on the terminal block.
Step 1: Insert the negative DC into the V- terminal and the positive DC
into the V+ terminal.
Step 2: To keep the DC wires from pulling loose, use a small flat-blade
screwdriver to tighten the wire-damp screws in the front of the terminal
block connector.

Power over Ethernet Warning

Use only with IEEE 802.3af compliant power sources. Power over Ethernet is optional on port 1.
DO NOT attempt to apply Power over Ethernet on port 2
Serial Connector
(-s models only)
Pin #
RS-232
RS-422
1
DCD
Tx-
2
RxD
Tx+
3
TxD
Rx+
4
DTR
Rx-
5
GND
GND
6
DSR
N/C
7
RTS
N/C
8
CTS
N/C
9
RI
N/C

Status LED Codes

Normal Operation
On Steady
O O = =
Conductor Blink
O O O = = O = =
Missing Identity
O O = = O = =
Factory Reset
O = O = (fast blink)
Diagnostic Mode
Revision Date: April 7, 2017
HIPSWITCH™-100 SERIES
e-mail: support@temperednetworks.com
Phone: +1 206.452.5500 ext. 2
www.temperednetworks.com
3101 Western Ave.
Ste. 550
Seattle, WA 98121
Hardened. Resilient. Simple.
HIPswitch™-100 Series
10/100
4g
Serial
Ethernet
Cellular
2
No
No
2
Yes
No
2
No
Yes
2
Yes
Yes
RS-485
RS-485
(4-wire)
(2-wire)
Tx-
DATA-
Tx+
DATA+
Rx+
N/C
Rx-
N/C
GND
GND
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
O Blink
No Conductor Connection O O O O = = O O = =
O O O O = = O O O = =
System Error
O O O O = = =
Secure Network Error
O O O O = = O = =
No Shared Network
O O O = = O O = =
Downloading Firmware
O O O = = =
Updating Firmware
PLATFORM GUIDE
802.3af PoE
Yes
Yes
Yes
Yes
= Pause

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HIPSWITCH 100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TEMPERED HIPSWITCH 100 Series

  • Page 1 NOTE: Some Tempered Networks documents may refer to this as a “Reset” button. Reduced Air Flow: Make sure the mount of air flow required for safe operation of the equipment is not compromised during installation.
  • Page 2 .pkg file has been created, you will be provided a download link to the file. A support bundle .pkg file is an encrypted archive that facilitates technical support by Tempered Networks only. A HIPswitch will appear online in the Conductor user interface once provisioning is complete. An authorized user can then log into the Conductor, add the HIPswitch to an overlay network, configure Send the support bundle as an email attachment to support@temperednetworks.com.

This manual is also suitable for:

Hipswitch-100eHipswitch-100gHipswitch-100e-gHipswitch-100g-s101e-201101g-201 ... Show all

Table of Contents