WARNING: Manual lighting
must be performed by a qualifi ed
ser vice per son.
The system has a "MANUAL OVERRIDE"
feature that allows you to light with a match.
Lighting with a Match
1. STOP! Read the safety information on
Page 17.
2. Make sure equipment shutoff valve is ful ly
open.
3. Turn motor knob clockwise to
OFF position.
4. Wait (5) minutes to clear any gas and
then smell for gas around heater and near
fl oor. If you smell gas, STOP! follow "B"
f i r e - p a r t s . c o m
on Page 17. If you do not smell gas, go
to the next step.
5. Make sure ON/OFF switch is in "–" (ON)
position.
6. MAN-knob (valve) in MAN position, a
metallic core is visible (see Figure 19).
7. Push and hold down metal core fully by
using a non-sharp object such as a pen.
This lets the pilot gas fl ow.
8. Light pilot burner with a match, (see
Figure 20).
9. Continue holding down metal core for
about 10 seconds. Pilot should stay lit
after releasing metal core. If not, repeat
step 1 thru 4.
10. Turn MAN knob to the ON position. This
lets main gas fl ow.
Piezo
Metallic
Igniter
Core for
Tab
Manual
Ignition
Piezo Igniter
ON/OFF Switch
Figure 19 - Control Valve
20
OPERATION
PROCEDURE
Motor
MAN Knob
Knob
in Manual
in ON
Position
Position
Microswitch
Continued
11. Turn motor knob to adjust fl ame. Knob has
a slipping clutch that allows manual fl ame
height adjustment as well as adjustment
to pilot gas.
Thermocouple
Figure 20 - Pilot
Lighting with Piezo Igniter
1. Disconnect igniter cable from receiver and
connect to Piezo Igniter Tab (see Figure
19 and Wiring Diagram on Page 26).
to
2. STOP! Read safety information on
Page 17,
3. Make sure equipment shutoff valve is fully
open.
4. Turn motor knob clockwise
OFF position.
5. Wait (5) minutes to clear any gas and
then smell for gas around heater and
near fl oor. If you smell gas, STOP! follow
"B" on Page 17.
6. ON/OFF switch in "—" ON position.
7. MAN knob on valve is in MAN position
(see Figure 19), When in MAN position
you can see a metallic core.
8. Push and hold down metal core fully with
a pen while the pilot gas fl ows.
9. Press and release piezo igniter button until
pilot lights.
10. Continue holding down metal core for
about 10 seconds and then release the
metal core. Pilot should stay lit. If not,
repeat steps 1 through 4.
11. Turn MAN Knob to ON position - main gas
fl ows.
12. Turn motor knob to adjust fl ame. Knob
has a slipping clutch that allows manual
fl ame height adjustment.
TO TURN GAS OFF
TO APPLIANCE
Press OFF button on remote control to switch
off main gas and pilot gas or manually turn
Motor knob clockwise
position.
Astria.us.com
Pilot Burner
to the
to the "O" OFF