IHP astria FIREPLACES Montebello18NE Installation And Operation Instructions Manual

Unvented (vent-free) gas log heater

Advertisement

Quick Links

P/N 126813-01 REV. B 05/2017
P126813-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
f i r e - p a r t s . c o m
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases.
WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built
fi replace or in a listed ventless fi rebox enclosure. It is design-certifi ed for these installations in accordance
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fi replace that includes
instructions stating it has not been tested or should not be used with unvented gas logs.
This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on Page 6 of this manual.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
- Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
Installation and Operation Instructions
Unvented (Vent-Free) Gas Log Heater
Models
PFS
®
US
Report No. F09-132
Montebello18NE
Montebello18PE
Montebello24NE
Montebello24PE

Advertisement

Table of Contents
loading

Summary of Contents for IHP astria FIREPLACES Montebello18NE

  • Page 1 Installation and Operation Instructions Unvented (Vent-Free) Gas Log Heater Models P/N 126813-01 REV. B 05/2017 ® Montebello18NE Montebello18PE Montebello24NE Montebello24PE Report No. F09-132 P126813-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. f i r e - p a r t s . c o m This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ..............2 Cleaning and Maintenance ........ 22 Product Identifi cation ........... 5 Troubleshooting ..........23 Local Codes............5 Wiring Diagram ..........26 Unpacking............5 Replacement Parts ..........27 Product Features ..........6 Service Hints ............. 27 Air For Combustion and Ventilation .....
  • Page 3 SAFETY Continued IMPORTANT: Read this owner’s WARNING: Do not place log manual carefully and completely scraps or volcanic stone on burner. before trying to assemble, op- erate or service this fi replace. Due to high temperatures, the ap- Improper use of this fi replace pliance should be located out of can cause serious injury or traffi...
  • Page 4 SAFETY Continued across openings of fi replace. Installation and repair should be 8. To prevent the creation of soot, follow the done by a qualifi ed service person. instructions in Cleaning and Maintenance, The appliance should be inspected Page 22. before use and at least annually by 9.
  • Page 5: Product Identification

    PRODUCT IDENTIFICATION Log Set Assembly Left Side Right Side Front Control Valve with Hand-Held Remote Receiver Remote Control Module Chassis Assembly Figure 1 - Product Identifi cation LOCAL CODES NOTE: Do not pick up assembly by logs. This could damage heater. Always handle Install and use appliance with care.
  • Page 6: Product Features

    PRODUCT FEATURES OPERATION SAFETY PILOT This heater is clean burning. It requires no This heater has a pilot with an Oxygen Deple- outside venting. There is no heat loss out a tion Sensing (ODS) safety shutoff system. The vent or up a chimney. Heat is generated by ODS/pilot is a required feature for vent-free realistic fl...
  • Page 7 AIR FOR COMBUSTION AND VENTILATION Continued installed is confi ned or unconfi ned space. The 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support. standard method defi nes a confi ned space as a space whose volume is less than 50 cubic ________ (volume of space) x 20 = (Maxi- mum Btu/Hr the space can support)
  • Page 8 AIR FOR COMBUSTION AND VENTILATION Continued Ventilation Air From Outdoors WARNING: If the area in which Provide extra fresh air by using ventilation the heater may be operated does grills or ducts. You must provide two perma- not meet the required volume for nent openings: one within 12"...
  • Page 9: Installation

    INSTALLATION NOTICE: This appliance is in- WARNING: Never install the tended for supplemental heat- heater ing. Use this heater along with • in a bedroom or bathroom your primary heating system. Do • in a recreational vehicle not install this heater as your pri- •...
  • Page 10 INSTALLATION Continued B. Clearances from the top of the fi replace WARNING: This appliance is opening to the ceiling should not be less equipped for either natural gas than 42". or propane/LP gas but not both. Maintain adequate clearances for accessibility for purposes Gas type is indicated on the rat- of servicing and proper operation.
  • Page 11 INSTALLATION Continued Noncombustible Requirements for Safe Installation Material Distance 12" or more Noncombustible material OK Between 8" and Install fi replace hood accessory ( see 12" Accessories, Page 27). Less than 8 Noncombustible material must be ex- tended to at least 8". See Between 8" and 12", above.
  • Page 12 INSTALLATION Continued MANTEL CLEARANCES FLOOR CLEARANCES In addition to meeting noncombustible mate- A. If installing appliance on the fl oor level, rial clearances, you must also meet required you must maintain the minimum distance clearances between fi replace openings and of 14"...
  • Page 13 INSTALLATION Continued INSTALLING HEATER ASSEMBLY Installation Items Needed • control cover kit (provided with heater) CAUTION: Do not remove the • approved fl exible gas hose (if allowed by local codes) data plates attached to the heater • sealant (resistant to propane/LP gas, not base assembly.
  • Page 14 CONNECTING TO GAS SUPPLY For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. WARNING: This appliance You must reduce incoming gas pressure to requires a 3/8" NPT (National between 11" and 14" of water. If you do not Pipe Thread) inlet connection to reduce incoming gas pressure, heater regula- the pressure regulator.
  • Page 15 INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Use pipe joint sealant that is resistant to liquid WARNING: Test all gas piping petroleum (LP) gas. and connections, internal and external to unit, for leaks after We recommend that you install a sediment installing or servicing.
  • Page 16 INSTALLATION Continued Test Pressures Equal To or Less Than PRESSURE TESTING HEATER GAS 1/2 PSIG (14" W.C.) CONNECTIONS 1. Close equipment shutoff valve (see Fig- 1. Open equipment shutoff valve (see Fig- ure 13). ure 13). 2. Pressurize supply piping system by either 2.
  • Page 17: Operation

    Logs in Front of ment embers are needed, the Burner replacement embers must be Figure 17 - Placement of Volcanic Stone purchased from IHP. See Page 29 for part numbers. OPERATION WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY •...
  • Page 18 OPERATION Continued REMOTE LIGHTING WARNING: Burner will come INSTRUCTIONS on automatically within one min- WARNING: ute after pilot burner is lighted. • If fi replace has glass doors, never operate this heater with 6. Press the buttons at the same time.
  • Page 19 OPERATION Continued Shut Off Procedure The controller compares the room tem- To save battery power, press to turn main perature with set temperature and sends gas to pilot gas. Press the OFF button to a signal to the receiver to turn gas valve shut off the device including pilot fl...
  • Page 20 OPERATION Continued MANUAL LIGHTING 11. Turn motor knob to adjust fl ame. Knob has PROCEDURE a slipping clutch that allows manual fl ame height adjustment as well as adjustment WARNING: Manual lighting to pilot gas. must be performed by a qualifi ed Pilot Burner Thermocouple ser vice per son.
  • Page 21: Inspecting Burners

    INSPECTING BURNERS BURNER FLAME PATTERN Check pilot fl ame pattern and burner fl ame patterns often. Figure 23 shows correct burner fl ame pattern. PILOT FLAME PATTERN NOTICE: Do not mistake orange Figure 21 shows a correct pilot fl ame pattern. fl...
  • Page 22: Cleaning And Maintenance

    CLEANING AND MAINTENANCE 2 . Remove screws from left and right side of WARNING: Turn off heater front log assembly to remove from base assembly (see Figure 25). and let cool before cleaning. 3. Inspect burner and primary air inlet holes on injector holder of each burner for dust CAUTION: You must keep con- and dirt (see Figures 25 and 26).
  • Page 23: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualifi ed service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. NOTE: All troubleshooting items are listed in order of operation. OBSERVED PROB- POSSIBLE CAUSE REMEDY...
  • Page 24 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Delayed ignition burner 1. Manifold pressure is too 1. Contact local natural or propane/LP gas company 2. Burner orifi ce(s) clogged 2. Clean burner (see Clean- ing and Maintenance, Page 22) or replace burner orifi...
  • Page 25 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 26: Wiring Diagram

    TROUBLESHOOTING Continued IDENTIFYING ERROR SIGNALS FROM RECEIVER OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Long signals (0.8 second Battery nearly down. (When Replace battery tone, 0.2 second break) dur- signal appears the fi rst time ing ignition approximately 10 ignitions left) 5 second continuous tone Cable is not connected, ON/ Connect cables OFF switch is in OFF position...
  • Page 27: Replacement Parts

    1. The model number of the appliance. Normally, all parts should be ordered through your 2. The serial number of the appliance. IHP distributor or dealer. Parts will be shipped at 3. The part number. prevailing prices at time of order.
  • Page 28 ACCESSORIES Continued FLOOR MEDIA KIT Cat. No. F1762, Model FM100 WALL-MOUNT THERMOSTAT SWITCH For all models. Includes volcanic stone, Cat. No. F2040, Model GWMT1 burner embers, and burner cinders For all models. The desired comfort setting can be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected.
  • Page 29: Parts

    PARTS MONTEBELLO18NE, MONTEBELLO18PE, MONTEBELLO24NE, AND MONTEBELLO24PE CAT. NO. MODEL F0094 Montebello18NE F0095 Montebello18PE F0096 Montebello24NE F0097 Montebello24PE f i r e - p a r t s . c o m WARNING: Failure to po- sition the parts in accordance with these diagrams or failure to use only parts specifi...
  • Page 30 PARTS This list contains replaceable parts used in your heater. When ordering parts, follow the in- structions listed under Replacement Parts on Page 27 of this manual. PART NUMBER DESCRIPTION QTY. Montebello18NE Montebello18PE Montebello24NE Montebello24PE Base Base Support J5258 J5257 J5243 J5244 Left Burner Bracket...
  • Page 31: Warranty

    In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108;...
  • Page 32 Dealer name f i r e - p a r t s . c o m IHP reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.

Table of Contents