BA00430C/07/EN/14.19
71453974
2019-01-07
Products
Operating Instructions
Flexdip CYH112
Holder for water and wastewater assemblies
Solutions
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flexdip CYH112 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Endress+Hauser Flexdip CYH112

  • Page 1 Products Solutions Services BA00430C/07/EN/14.19 71453974 2019-01-07 Operating Instructions Flexdip CYH112 Holder for water and wastewater assemblies...
  • Page 3: Table Of Contents

    Flexdip CYH112 Table of contents Table of contents About this document ....4 Warnings ......4 Symbols used .
  • Page 4: About This Document

    About this document Flexdip CYH112 About this document Warnings Structure of information Meaning This symbol alerts you to a dangerous situation. DANGER Failure to avoid the dangerous situation will result in a fatal or serious Causes (/consequences) injury. If necessary, Consequences of non-compliance (if applicable) ‣...
  • Page 5: Basic Safety Instructions

    Flexdip CYH112 Basic safety instructions Basic safety instructions Requirements for the personnel • Installation, commissioning, operation and maintenance of the measuring system may be carried out only by specially trained technical personnel. • The technical personnel must be authorized by the plant operator to carry out the specified activities.
  • Page 6: Operational Safety

    Basic safety instructions Flexdip CYH112 Operational safety Before commissioning the entire measuring point: 1. Verify that all connections are correct. 2. Ensure that electrical cables and hose connections are undamaged. 3. Do not operate damaged products, and protect them against unintentional operation.
  • Page 7: Product Description

    Flexdip CYH112 Product description Product description Product design A0037898  1 Example of mounted CYH112 holder Base Main pipe Multifunctional clamp ring Transverse pipe Cross clamp Immersion pipe of the CYA112 assembly Endress+Hauser...
  • Page 8 Product description Flexdip CYH112 A0037909  2 Example of mounted CYH112 holder with chain Base Main pipe Chain Multifunctional clamp ring Cross clamp Transverse pipe Immersion pipe of the CYA112 assembly Always hook the bracket of the assembly through the last link in the chain.
  • Page 9: Incoming Acceptance And Product

    Flexdip CYH112 Incoming acceptance and product identification Incoming acceptance and product identification Incoming acceptance 1. Verify that the packaging is undamaged.  Notify the supplier of any damage to the packaging. Keep the damaged packaging until the issue has been resolved.
  • Page 10: Product Identification

     A new window (Device Viewer) opens. All of the information relating to your device is displayed in this window as well as the product documentation. 4.2.3 Manufacturer's address Endress+Hauser Conducta GmbH+Co. KG Dieselstraße 24 D-70839 Gerlingen Scope of delivery The delivery comprises: •...
  • Page 11: Certificates And Approvals

    Flexdip CYH112 Incoming acceptance and product identification Certificates and approvals Explosion protection The CYH112 holder may also be used in hazardous areas in Zone 1 and 2. The holder does not fall within the scope of ATEX Directive 2014/34/EU as it does not have a potential source of ignition of its own.
  • Page 12: Installation

    Installation Flexdip CYH112 Installation Installation conditions 5.1.1 Mounting instructions The maximum extension depends on the suspended load (weight of immersion pipe, assembly and cable). See the following diagram for this purpose: 14.3 1200 1000 inch 19.7 29.5 39.4 47.2 A0010837 ...
  • Page 13: Mounting The Holder

    Flexdip CYH112 Installation 5.1.2 Dimensions 1200 (47.2) A0010838  4 Dimensions with maximum extension. Dimensions: mm (in) The values indicated are valid for floor, wall and rail mounting. Mounting the holder For more information on mounting the assembly with the holder, see Operating Instructions BA00432 5.2.1...
  • Page 14 Installation Flexdip CYH112 A0010865  5 Measuring system with CYH112 holder Main pipe secured to floor Transmitter Protective cover Transverse pipe with fastening elements Hook-and-loop cable ties Chain CPA111 assembly 5.2.2 Mounting the base Use the M10 chemical anchor to mount the base on a concrete floor.
  • Page 15 Flexdip CYH112 Installation 5.2.3 Mounting the main pipe A0038457  6 Multifunctional clamp ring Slot in the multifunctional clamp ring Multifunctional clamp ring, funnel-shaped side 1. Attach the multifunctional clamp ring to the main pipe, with the funnel-shaped side pointing downwards.
  • Page 16 Installation Flexdip CYH112 A0038385  8 Base with main pipe Main pipe Base Hook-and-loop cable ties Clamps with clamp screws 1. Set the clamps in the base in position →  7,  15. 2. Insert the main pipe into the base →  8,  16.
  • Page 17 Flexdip CYH112 Installation 5.2.5 Mounting the flange clamp A0038901  10 Flange clamp Clamps Hook-and-loop cable ties Flange clamp Clamp screw Fastening holes on flange clamp Use M8 chemical anchors to mount on a concrete floor or a concrete wall.
  • Page 18 Installation Flexdip CYH112 5.2.7 Installing the rail mounting, pendulum holder or immersion pipe tray A0038906 A0038908  11 Rail mounting  12 Immersion pipe tray Retaining screw in clamping jaw Clamping jaw Clamping jaw Retaining screw in clamping jaw Retaining screw...
  • Page 19 Flexdip CYH112 Installation A0011312  14 Fitting the holder on the support Mounting on a square support Mounting on a circular support Retaining screw Retaining screw in clamping jaw In the case of square supports, mount the clamping jaw with the V-notch facing outwards;...
  • Page 20 Installation Flexdip CYH112 5.2.9 Mounting the cross clamp on the pendulum holder A0038914  15 Mounting the cross clamp on the pendulum holder Cross clamp Pendulum holder with pendulum adapter 1. Adjust the clamps on the cross clamp →  15.
  • Page 21 Flexdip CYH112 Installation A0035832  17 Mounting the multifunctional clamp rings on the transverse pipe Triangular carabiner as anti-slip lock for the chain Multifunctional clamp ring (stand side), slot facing downwards Multifunctional clamp ring (basin side), slot facing upwards Slot in the multifunctional clamp ring Mounting the transverse pipe: 1.
  • Page 22 Installation Flexdip CYH112 5.2.11 Mounting the transverse pipe for assembly chain retainer without a main pipe A0035833  18 Installation on coping stone Flange clamp Transverse pipe Multifunctional clamp ring (basin side), slot facing upwards Multifunctional clamp ring (stand side), slot facing downwards...
  • Page 23 Flexdip CYH112 Installation 5.2.12 Mounting the pendulum holder on the coping stone A0038917  19 Mounting the pendulum adapter on a coping stone Use M10 chemical anchors to mount the pendulum holder on a coping stone. 1. Mark the securing points for the pendulum holder on the floor.
  • Page 24 Installation Flexdip CYH112 A0011403  21 Mounting the quick-action clamp on the cross clamp Quick-action clamp Clamps Clamp screw 1. Cut off the hook-and-loop cable ties used to secure the existing clamps. 2. Remove the clamping unit (clamps and clamping screw).
  • Page 25: Mounting Options

    Flexdip CYH112 Installation In the case of rail mounting, the multifunctional clamp ring acts as an anti-slip lock. Multifunctional clamp ring →  35 ‣ Mount the multifunctional clamp ring at the desired height. Mounting options 5.3.1 Floor mounting A0037664 ...
  • Page 26 Installation Flexdip CYH112 5.3.2 Wall mounting A0037897  25 Mounting on a wall with main pipe and transverse pipe A0037899  26 Mounting on a wall with transverse pipe Endress+Hauser...
  • Page 27 Flexdip CYH112 Installation A0037901  27 Mounting on a wall with main pipe, transverse pipe and chain A0037902  28 Mounting on a wall with transverse pipe and chain Endress+Hauser...
  • Page 28 Installation Flexdip CYH112 5.3.3 Rail mounting A0037904  29 Mounting on a rail with main pipe and transverse pipe A0037906  30 Mounting on a rail with transverse pipe Endress+Hauser...
  • Page 29: Post-Installation Check

    Flexdip CYH112 Installation A0037907  31 Mounting on a rail with main pipe, transverse pipe and chain A0037908  32 Mounting on a rail with transverse pipe and chain Post-installation check • After mounting, check that all the screws are securely tightened.
  • Page 30: Operation Options

    Operation options Flexdip CYH112 Operation options WARNING Wastewater There is a risk of infection when working with wastewater! ‣ Wear protective gloves, protective goggles and protective clothing. Operating the pendulum holder A0011366  33 Specifying the swing axis Swing axis with rotating sleeve blocked...
  • Page 31: Maintenance

    Flexdip CYH112 Maintenance Maintenance WARNING Wastewater There is a risk of infection when working with wastewater! ‣ Wear protective gloves, protective goggles and protective clothing. Maintenance tasks A0011372  34 Immersion pipe tray for assembly maintenance position Immersion pipe tray The immersion pipe tray makes it easier to perform maintenance tasks with rail mounting involving a pendulum holder and cross clamp.
  • Page 32 Maintenance Flexdip CYH112 7.1.1 Setting the assembly to the service position (fixed installation) A0037661  35 Setting the assembly to the service position Rotational movement 1 Rotational movement 2 1. Release the clamp screws on the cross clamp. 2. Move the transverse pipe with the assembly to the stand side (rotational movement 3.
  • Page 33 Flexdip CYH112 Maintenance 7.1.2 Setting the assembly to the service position (chain retainer) A0037663  36 Setting the assembly to the service position Measuring position Service position 1. Pull up the assembly by the chain as far as possible. 2. Suspend the chain from the multifunctional clamp ring and secure the chain with the triangular carabiner.
  • Page 34: Repair

    The product must be returned if repairs or a factory calibration are required, or if the wrong product was ordered or delivered. As an ISO-certified company and also due to legal regulations, Endress+Hauser is obliged to follow certain procedures when handling any returned products that have been in contact with medium.
  • Page 35: Accessories

    Flexdip CYH112 Accessories Accessories The following are the most important accessories available at the time this documentation was issued. ‣ For accessories not listed here, please contact your Service or Sales Center. Dipfit CLA111 • Immersion assembly for open and closed vessels with flange DN 100 •...
  • Page 36 Accessories Flexdip CYH112 Ø 86 (3.39) Ø 80 (3.15) 100° 60 (2.36) Ø 71.45 (2.81) (1.83) 15 (0.59) 5 (0.2) 11.2 (0.44) (0.98) A0035699  37 Multifunctional clamp ring. Dimensions: mm (in) Immersion pipe tray • Is used to hold the immersion pipe during maintenance work •...
  • Page 37 Flexdip CYH112 Accessories (0.12) 93.5 (3.68) 65 (2.56) 10 (0.39) 48 (1.89) 23 (0.91) 89.5 (3.52) 6 (0.24) 79.9 (3.15) (0.59) 16 (0.63) (0.47) 66.4 (2.61) A0035703  38 Immersion pipe tray. Dimensions: mm (in) Triangular carabiner • Is used to secure the chain •...
  • Page 38 Accessories Flexdip CYH112 46 (1.81) A0035705  39 Triangular carabiner. Dimensions: mm (in) Hook-and-loop cable ties (set of 4) • Is used to secure the cables • Material: PE/PA (polyethylene/polyamide) • Order number: 71092051 Allen key • Across flats: AF 6 •...
  • Page 39 Flexdip CYH112 Accessories 30 (1.18) 66(2.60) Ø 8 (0.31) 55 (2.17) A0005091  41 Circular post mounting for CYY101. Dimensions: mm (in) Overvoltage protection HAW56X surge arrester and associated installation material Quick-action clamp Order number: 71092050 Nylon chain • Minimum length 5 m (16.4 ft) •...
  • Page 40: Technical Data

    Technical data Flexdip CYH112 Technical data 10.1 Environment Ambient temperature -20 to 60 °C (-4 to 140 °F) range 10.2 Mechanical construction Design, dimensions Main pipe: Ø 40 mm (1.57 in), length: 500, 1000 and 1800 mm (19.7, 39.4 and 70.9 in)
  • Page 41 Flexdip CYH112 Technical data Flange clamp 110 (4.33) 47 (1.85) 60 (2.36) 111 (4.37) (1.69) A0035771  43 Dimensions of the flange clamp. Dimensions: mm (in) 80 (3.15) A0010885  44 Dimensions of the boreholes of the flange clamp. Dimensions: mm (in)
  • Page 42 Technical data Flexdip CYH112 Pendulum adapter 12 (0.47) 12 (0.47) 50 (1.97) 79 (3.11) A0011252  45 Dimensions of the pendulum adapter. Dimensions: mm (in) Weight • Main pipe • Length 500 mm (19.7 in): 0.7 kg (1.5 lb) • Length 1 000 mm (39.4 in): 1.5 kg (3.3 lb) •...
  • Page 43 Flexdip CYH112 Technical data * The flange clamp, cross clamp and base clamping element are made from the material indicated with the exception of the clamps in the clamping device, which are made from stainless steel 1.4301 or 1.4305 (AISI 304). The pendulum holder is made from the material indicated with the exception of the shaft and the clamps in the clamping device, which are made from stainless steel 1.4301 or 1.4305 (AISI 304).
  • Page 44: Index

    Index Flexdip CYH112 Index Accessories ....... . 35 Approvals ....... . . 11 Certificates .
  • Page 48 *71453974* 71453974 www.addresses.endress.com...