FLOOR PROTECTION
The American Harvest Multifuel Stove may be installed on a combustible floor, with proper floor protection, or on a
masonry hearth. The hearth or noncombustible floor protector must extend a minimum of (6) inches (152mm)in front
and (6) inches (152mm) from each side of the ash removal door.
The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE:
These are minimum clearances to combustible walls established by the testing lab. The amount of room needed on the left
side of the unit to access the electrical panel is (6) six inches (152mm).
PARALLEL - A - Left Sidewall to Top Edge of Unit
B - Sidewall to Flue
C - Backwall to Flue
D - Backwall to Unit
E - Right Sidewall to Top Edge of Unit
CORNER -
F - Adjacent Wall to Flue
G - Adjacent Wall to Unit
Alcove / Backwall / Sidewall
Parallel / Alcove Installation
USSC
INSTALLATION REQUIREMENTS
CLEARANCES TO COMBUSTIBLES
BACK WALL
6 in./152mm
5 in./127mm
3 in./75mm
9 in./228mm
2 in./50mm
3 in./75mm
4 in./100mm
BACK WALL
Corner Installation
5