Natural Gas
Manifold Pressure Setting 4" w.c.
Gas Inlet Pressure
Maximum 10-1/2" w.c.
Minimum 5" w.c.
Model Number
9945N
Propane / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manifold Pressure Setting 10" w.c.
Gas Inlet Pressure
Maximum 13" w.c.
Minimum 11" w.c.
Model Number
9945L
Controls - Main control has 4 positions:
1. OFF - All gas to the burner is shut off at the control
2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3. PILOT - Valve position to light/maintain a standing pilot
4. ON - Gas flow to complete system.
HIGH / LOW Control - Infinite control :
Rotate knob clockwise to LOW, counter clockwise to HIGH.
9945L and 9945N Unvented Gas Heaters
1. Packet containing Homeowners/Installation instructions.
2. Three(3) individually wrapped fiber ceramic logs, refer to installation instructions.
3. Unvented gas heater.
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS
TO
PREVENT SKIN
FRAGILE, HANDLE WITH CARE.
Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.
Type
Max BTU/Hr
Manual
39,900
Type
Max BTU/Hr
Manual
39,900
IRRITATION FROM LOOSE FIBERS. LOGS ARE
5
SPECIFICATIONS
Gas Rate
Min BTU/Hr
27,000
Gas Rate
Min BTU/Hr
27,000
Number
of Burners
1
Number
of Burners
1
CONTENTS