USSC Ambiance B9945L Installation And Operation Instructions Manual page 13

Signature series natural and propane gas vent-free pedestal heater
Table of Contents

Advertisement

OPERATING INSTRUCTIONS
1.
STOP! Read the safety information on the
previous page.
2.
Set the thermostat to lowest setting.
3.
Turn off all electrical power and open the
access door.
4.
Push in gas control (B) slightly and turn clock
wise
to "OFF".
5.
Push "ON / OFF" switch to "OFF" position.
B
A
C
NOTE: Knob cannot be turned from "PILOT" to
"OFF" unless knob is pushed in slightly. Do not
force.
6.
Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you
smell gas, STOP! Follow "B" in the safety
information on the previous page. If you don't
smell gas, go on to the next step.
7.
Depress knob (B) and turn gas control knob
counterclockwise
8.
Push in knob (B) all the way and hold in.
Immediately light the pilot by pushing in on the
piezo button (A). Continue to hold the control
knob in for about one(1) minute after the pilot
is lit. Release knob and it will pop back up. Pilot
should remain lit. If it goes out, repeat steps 4
through 8.
1.
Open access door.
2.
Turn switch (D) to "OFF"
3.
Unplug all electric power (optional blower) if service is to be performed.
4.
Push in gas control knob slightly and turn clockwise
5.
Close access door.
LIGHTING INSTRUCTIONS
D
to "Pilot".
TURN OFF GAS TO APPLIANCE
13
TOP VIEW OF BURNER ASSEMBLY
If the pilot does not pop up when released, stop
and immediately call your service technician
or gas supplier. If the pilot will not stay lit after
several tries, turn control knob to "OFF" and
call your gas supplier.
9.
Turn valve knob clockwise
10. Wait about one minute then turn burner switch
(D) to "ON". It will take a few minutes for the
thermopile located on top of the pilot to heat
up.
NOTE: If unit is equipped with remote "on-off" wall
switch, switch must be in "on" position for burner to
light.
11. Adjust flame height with the high-low knob (C).
12. Turn on all electrical power to the appliance.
13. Close access door.
NOTE: It is normal for the new heater to give off
some odor the first time it is burned. This is due to
the curing of the paint and any undetected oil from
the manufacturing process.
It is recommended that you burn your new heater for
at least two(2) hours the first time you use it. If
optional fan kit is installed, leave it turned off for the
break in period.
to the "OFF" position.
to "ON".

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ambiance b9945n

Table of Contents