6mm 4500rpm mini 90 degrees angle air drill key chuck

Advertisement

WArning! Be prepared for drill bit binding on break through. When these situations occur the drill has a tendency to grab and kick
in the opposite direction which could cause loss of control. If you are not prepared, this loss of control can result in damage and/or
personal injury.
5.2.7.
If the drill bit jams in the work piece or if the drill stalls, release the trigger switch immediately. Remove the drill bit from the work piece
and determine the reason for jamming.
6. mAinTenAnCe
WArning! disconnect drill from air supply before changing drill bit, servicing or performing maintenance. Replace or repair
damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
6.1.
Lubricate the drill daily with a few drops of good grade air tool oil, such as Sealey ATO/500 or ATO/1000, dripped into the air inlet
before use or dispensed automatically through an air system oiler, such as Sealey model number SA106l.
6.2.
Clean the drill after use and change the drill bit when worn or damaged.
6.3.
loss of power or erratic action may be due to the following:
a) excessive drain on the air supply. Moisture or restriction in the air line. Incorrect size or type of hose connectors. To remedy
check the air supply and follow instructions in Section 4.
b) Grit or gum deposits in the drill may also reduce performance. Flush the drill with gum solvent oil or an equal mixture of SAe
no.10 oil and kerosene. Allow to dry before use. If you continue to experience problems, contact your local Sealey service agent.
6.4.
For a full service contact your local Sealey service agent.
6.5.
When not in use, disconnect from air supply, clean drill and store in a safe, dry, childproof location.
This tool may cause hand Arm vibration Syndrome if its use is not managed adequately.
This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC.
This tool is to be operated in accordance with these instructions.
measured vibration emission value (a): . . . . . . . . . 0.461m/s²
uncertainty value (k):. . . . . . . . . . . . . . . . . . . . . . . . . 0.541m/s²
Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a
specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.
A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool.
nB: Stated Vibration Emission values are type-test values and are intended to be typical.
Whilst in use, the actual value will vary considerably from and depend on many factors.
Such factors include; the operator, the task and the inserted tool or consumable.
nB: ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.
The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration
Syndrome.
health surveillance.
We recommend a program of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified
accordingly.
personal protective equipment.
We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the
uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry
and maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use
and Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSC website
www.hse.gov.uk - Hand-Arm Vibration at Work.
environmenT proTeCTion
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 24 months from purchase date, proof of which is required for any claim.
Sealey group, Kempson Way, Suffolk Business park, Bury St edmunds, Suffolk. ip32 7Ar
01284 757500
© Jack Sealey limited
WArning! – risk of hand Arm vibration injury.
01284 703534
Original Language Version
sales@sealey.co.uk
www.sealey.co.uk
SA1008 Issue 2 (3) 19/12/19

Advertisement

loading