Index I. About AMR130-R/RN A. Hardware Specification--------------------------------------------------------------------------------02 B. Outward Appearance Overview --------------------------------------------------------------------02 II. Setting Details A. AMR130-R 1. Baud Rate-------------------------------------------------------------------------------------------03 2. Add--------------------------------------------------------------------------------------------------03 3. Read Parameter-------------------------------------------------------------------------------------03 4. Pulse Value (Read)---------------------------------------------------------------------------------04 5. ELC-------------------------------------------------------------------------------------------04 6. ADD-------------------------------------------------------------------------------------------------04 7. Dec---------------------------------------------------------------------------------------------------05 8. Pulse Value------------------------------------------------------------------------------------------05 B. RF Settings 1.
Long Distance Range Transmit Power DC Input DC 12V~15V / 12W I-B. Outward Appearance Overview: Indicator light: Input Power Green: AMR130-R/RN operating mode DC12V~15V Orange: RF setting mode Water Meter Pulse Input Pulse Indicator Micro USB RF TX/RX Indicator USB is only used to...
○ 2 Add: The default value of Add is 255. Please enter the Add that showed on the AMR130-R/RN hardware. ○ 3 Read Parameter: Please click the “Read Parameter” button to get corresponding parameters.
・Let’s assume that the blank Add at top-right corner is 255 and user enter 5 here. Then, all the ADD of AMR130-N will be transformed into 5. ・For another instance, the blank Add at top-right corner is 6 and user enter 20 here. Then, the AMR130-R/RN which is 6 will be transformed into 20.
○ 7 Dec Settings: ・Users could choose which decimal they want to adopt. (Integer / Decimal / Two Decimal Places) ・Please click “Set Dec” button to save after making any alteration. ○ 8 Pulse Rate Settings: ・There are multi choices of Pulse Rate. ・Please click “Set Pulse Rate”...
II.-B RF ○ 1 Connect & ○ 2 Read Parameter: ・Please click “Open Connect” button to activate setting tool. ・Please click “Read Parameters” button first to get the corresponding parameters. ❑Friendly Notice: The “Read Parameter”,“ Set Parameters” and “Reset Parameters” these three buttons will be activated after clicking “Open Connect”...
○ 5 RF ID: ・This address is different from the former one. It is the ID of RF. (Range: 0~65535) ○ 6 Channel & Feq: ・There are multi choices of Channel. The default value is 65. (Range: 52~77) ・The value of Feq will follow with Channel. ○...
○ 8 Reset Parameters ・Users could click “Reset Parameters” button to rectify again. ○ 9 Disconnect ・Please remember to click “Close connect” button to finish all the settings. ❑Friendly Notice: The indicator light has to be orange during setting parameters. It will turn into to green after clicking “Close Connect”.