Vega Absolute Smart-MS0101 User Manual

Motion sensor
Hide thumbs Also See for Smart-MS0101:

Advertisement

Quick Links

MOTION SENSOR
SMART-MS0101
User Manual
Infrared motion sensor Vega Smart-MS0101 is designed
to detect penetration into the protected area. The
sensor alternately operates in two modes: «Guard» and
«Neutral». Sends an alarm signal to the LoRaWAN™
network by the triggering.
www.vega-absolute.ru

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smart-MS0101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vega Absolute Smart-MS0101

  • Page 1 MOTION SENSOR SMART-MS0101 User Manual Infrared motion sensor Vega Smart-MS0101 is designed to detect penetration into the protected area. The sensor alternately operates in two modes: «Guard» and «Neutral». Sends an alarm signal to the LoRaWAN™ network by the triggering.
  • Page 2 Smart-MS0101 / User Manual Document Information Title Motion sensor Smart-MS0101 Document type Manual – Translation from Russian Document number V05-MS0101-01 Revision and date 08 – 03 October 2019 This document applies to the following products: Product name Type number Vega Smart...
  • Page 3: Table Of Contents

    “LoRaWAN settings” tab ..............................19 “Smart-MS0101” tab ................................23 5 COMMUNICATION PROTOCOL ............................24 SMART-MS0101 transmits the following types of packets ..................24 SMART-MS0101 transmits the following types of packets ..................26 6 STORAGE AND TRANSPORTATION REQUIREMENTS ....................28 7 CONTENT OF THE PACKAGE ............................. 29 8 WARRANTY .....................................
  • Page 4: Introduction

    Smart-MS0101 / User Manual INTRODUCTION This manual is designated for Vega Smart-MS0101 motion sensor (hereinafter – device, sensor) manufactured by Vega-Absolute LLC and provides information on powering and activation procedure, control commands and functions of the device. This manual is targeted at specialists familiar with installation work fundamentals for electronic and electrical equipment.
  • Page 5: Description And Operation

    The device arming time interval is setting up by the «Vega LoRaWAN Configurator» application and may vary from 1 to 60 minutes. Vega Smart-MS0101 can be used to protect premises, buildings and structures, as well as in Smart Home systems, built on LoRaWAN™ technology.
  • Page 6: Comunication And Data Collection Algorithm

    The internal clock is set automatically when device connected to the "Vega LoRaWAN Configurator" via USB, also adjustable via LoRaWAN. FUNCTIONAL Vega Smart-MS0101 motion sensor is class A device (LoRaWAN™ classification) and has the following features: o ADR support (Adaptive Data Rate)
  • Page 7 Smart-MS0101 / User Manual o DevEUI; o Month and year of manufacture; o QR-code containing DevEUI for automatized count. Sticker located in three places – on device case, in factory certificate and on the packing box. Besides, there is an additional sticker located on the packing box and contains: o Information about firmware version;...
  • Page 8: Specification

    Smart-MS0101 / User Manual 2 SPECIFICATION Main USB-port mini-USB, type B Operating temperatures -40…+70 °С Maximum detection range not less than 15 m Range of velocities of the intruder 0.3…3 m/s Sensor mounting height 2.1 m Angle of the sensor in the vertical plane 6°...
  • Page 9: Operation

    Smart-MS0101 / User Manual 3 OPERATION INDICATION A double color indicator is located on the front of the sensor case and it flashes red when detect motion in the protected area. Indicator on the Indicator on the front of the device...
  • Page 10: Initial Startup

    Smart-MS0101 / User Manual Meaning LED signal Linking to the network Series of short flashings The device connected to the network One long flashing and is in active mode Linking to the network is unsuccessful Three long flashings or the device switched to the «Storage»...
  • Page 11 Smart-MS0101 / User Manual Press the start button located on the board 2. OTAA. After pressing the start button, the device makes three attempts to connect to the network within the set frequency plan. After the activation request is confirmed by LoRaWAN™...
  • Page 12: Sensor Mounting Recommendations

    Smart-MS0101 / User Manual SENSOR MOUNTING RECOMMENDATIONS The sensor must be installed in such a way that the probable penetration paths of the intruder cross the central axis of the detection zone. Recommended mounting height of the sensor is 2…2,5 m.
  • Page 13: Connecting Via Usb

    Smart-MS0101 / User Manual CONNECTING VIA USB The device Smart-MS0101 can be configured with the "Vega LoRaWAN Configurator" application (See part 4). mini-USB Before connecting the device to the computer for the first time, you must install the driver for the COM port stsw-stm32102, which can be downloaded from iotvega.com. After running the executable file VCP_V1.4.0_Setup.exe, the installer window will appear:...
  • Page 14 Smart-MS0101 / User Manual In this window, you need to click Next, then Install, and then the installation will begin. When the installation is completed successfully, the following screen appears: After pressing Finish the driver is ready for operation, - it is possible to connect the device via USB.
  • Page 15: Vega Lorawan Configurator

    Smart-MS0101 / User Manual 4 VEGA LORAWAN CONFIGURATOR The "Vega LoRaWAN Configurator" application (hereinafter referred to as the configurator) is intended for setting up the device via USB. The configurator has two modes of operation - "Simple" and "Expert". In the "Simple"...
  • Page 16: Connection To The Device

    Smart-MS0101 / User Manual CONNECTION TO THE DEVICE For the connection to the device, perform the following steps: 1. Connect the USB cable to the device. 2. Start the "Vega LoRaWAN Configurator" application. 3. Click the "Connect" button in the menu on the left.
  • Page 17: Device Info" Tab

    Smart-MS0101 / User Manual “DEVICE INFO” TAB The "Device info" tab displays information about the device, its current status, and also the data needed to register the device in the LoRaWAN™ network. ABP info - displays the data necessary to register the device in the LoRaWAN™ network with ABP method (Activation By Personalization).
  • Page 18 Smart-MS0101 / User Manual number of gateways that received this signal and the signal quality. This button only works when the device is connected to the network. Device output (not displayed in the "Simple" mode) - monitoring the device status, all events in real time are displayed.
  • Page 19: Lorawan Settings" Tab

    Smart-MS0101 / User Manual “LORAWAN SETTINGS” TAB The "LoRaWAN Settings" tab allows you to configure various parameters of the LoRa network. Region - allows you to select one of installed frequency plans or specify a custom frequency plan. Custom frequency plan is EU-868 based.
  • Page 20 Smart-MS0101 / User Manual This frequency plan allows you to set up to 16 channels, as well as the frequency and speed of the second receiving window. The first three channels and the second receiving window parameters are mandatory. Without these parameters the custom frequency plan will be considered empty.
  • Page 21 Smart-MS0101 / User Manual RX1 offset (not displayed in the "Simple" mode) – specifies the time between end of packet transmission and first receiving window opening. The second receiving window always opens after 1 second after the first. Join accept delay 1 (not displayed in the "Simple" mode) – sets the time that the device will open the first receiving window to receive confirmation for the join request from the LoRaWAN™...
  • Page 22 Smart-MS0101 / User Manual Uplink number of transmission (not displayed in the "Simple" mode) – if the "Confirmed uplinks" function is disabled, the device will simply send each packet as many times as specified in this option. If "Confirmed uplinks" is enabled, the device will send packets until it receives a confirmation or until it sends as many packets as specified in this option.
  • Page 23: Smart-Ms0101" Tab

    Smart-MS0101 / User Manual “SMART-MS0101” TAB The “Smart-MS0101” tab contains the settings of the connected device. Current state – displays the current parameters of the device - the internal temperature of the device and the battery level. Guard settings – allows setting the time interval of auto-post to the “Guard” mode from 1 to 60 minutes.
  • Page 24: Communication Protocol

    Smart-MS0101 / User Manual 5 COMMUNICATION PROTOCOL This part describes the Smart-MS0101 communication protocol with LoRaWAN network. In fields consisting of several bytes, the little endian byte order is used SMART-MS0101 TRANSMITS THE FOLLOWING TYPES OF PACKETS 1. Packet with current readings, sent regularly, and every time alarm event occurs on...
  • Page 25 Smart-MS0101 / User Manual 2. Packet with time correction request, sent every seven days on LoRaWAN port 4 Size in bytes Field description Data type 1 byte Packet type, this packet == 255 uint8 4 bytes Time of the modem at the packet sending moment...
  • Page 26: Smart-Ms0101 Transmits The Following Types Of Packets

    Smart-MS0101 / User Manual SMART-MS0101 TRANSMITS THE FOLLOWING TYPES OF PACKETS 1. Real-time clock adjustment – sent by application on LoRaWAN port 4 Size in bytes Field description Data type 1 byte Packet type, this packet == 255 uint8 8 bytes...
  • Page 27 Smart-MS0101 / User Manual Table of ID of Smart-MS0101 parameters and these possible values ID of Description Data Possible values parameter length Confirmed uplinks 1 byte 1 – confirmed 2 – unconfirmed ADR (Adaptive Data Rate) 1 byte 1 – enabled 2 –...
  • Page 28: Storage And Transportation Requirements

    Smart-MS0101 / User Manual 6 STORAGE AND TRANSPORTATION REQUIREMENTS The Smart-MS0101 sensor shall be stored in the original packaging in heated room at temperatures +5°С to +40°С and relative humidity less than 85%. The sensor shall be transported in covered freight compartments of all types at any distance at temperatures -40°C to +85°C.
  • Page 29: Content Of The Package

    Smart-MS0101 / User Manual 7 CONTENT OF THE PACKAGE The sensor is delivered complete with: Motion sensor Vega Smart-MS0101 – 1 pc. CR123A battery – 1 pc. Factory certificate – 1 pc. Revision № 07 03 October 2019...
  • Page 30: Warranty

    Smart-MS0101 / User Manual 8 WARRANTY The warranty period for the device is 5 years from the date of sale. The manufacturer is obligated to provide repair services or replace the failed device during the entire warranty period. The consumer undertakes to comply with the terms and conditions of transportation, storage and operation specified in this user manual.
  • Page 31 Smart-MS0101 / User Manual vega-absolute.ru Operation Manual © Vega-Absolute LLC 2017 Revision № 07 03 October 2019...