If more than three years have elapsed since the issue date, contact ZOLL Medical Corporation to determine if additional product information updates are available. ZOLL is a registered trademark of ZOLL Medical Corporation. SurePower is a trademark of ZOLL Medical Corporation. All other trademarks and registered trademarks are property of their respective owners.
Page 3
Locate ZOLL resuscitation devices where they cannot harm the patient or medical personnel • if they fall -- accidental sliding or drop of the SurePower Battery Pack may cause physical injury. Damaged batteries may expose users to a safety hazard. Should the SurePower Battery Pack be dropped, inspect and test the unit prior to further use following the procedures described in this manual.
Page 4
Using the device in the presence of flammable agents can cause an explosion. Do not immerse or set the SurePower Battery Pack in liquid. Using the battery near or • within puddles of water may present a shock hazard to the operator, patient, and nearby personnel.
Page 5
ZOLL ships the SurePower Battery Pack in a partially charged state and you must fully charge the battery before first use. It is very important that you recharge a depleted SurePower Battery Pack as soon as possible. Caution Do not store fully depleted batteries or damage can result.
Page 6
ATTERY Displaying Battery Runtime The SurePower Battery Pack can display its present status. To display the status of the SurePower Battery Pack, press and release the Display button (momentary press) on the top of the battery. When you press and release the Display button, all LEDs blink to indicate that they work.
Cleaning Clean the SurePower Battery Pack with a soft damp cloth and mild soap. Do not immerse or set the SurePower Battery Pack in fluids of any kind. Do not use alcohol or ketones to clean the SurePower Battery Pack.
Page 8
ATTERY Extended Storage Do not store the SurePower Battery Pack for extended periods in a fully charged state. If you must store the SurePower Battery Pack for an extended period: 1. Charge the SurePower Battery Pack until three runtime LEDs light (this takes approximately 1 hour when charging a depleted battery).
Page 9
Understanding Battery Faults The SurePower Battery Pack can detect one or more simultaneously occurring faults that render the battery unfit for use. To determine the faults that affect a battery, follow this procedure when the fault light is on: Press and hold down the Display button for at least 15 seconds.
Page 10
-300 ft through 20,000 ft (below and above sea level) Altitude of Operation -91 m through 6096 m (below and above sea level) 1060 through 500 mBar *For extended storage periods, store the SurePower Battery Pack between to 77°F 60°F (15°C to 25°C) to minimize capacity loss.