NOTE: After a prolonged stop, slight water dripping could occur underneath the pump. Such dripping normally
disappears after a few hours of operation. Should it persist, contact a Skilled Technician.
WARNING
• Follow the maintenance instructions contained in the manual of the machine in which the pump is
integrated.
• All maintenance jobs must only be performed after carrying out the operations described in the
paragraph, meaning without any moving parts, no pipe full of liquid under pressure and only after complete
cooling.
In particular, always remember to disconnect the power supply.
• Any maintenance jobs must be performed in conditions of total stability.
• WARNING. To ensure the safety of the pump, only use original spare parts supplied by the Manufacturer or
approved by it.
Perform the routine maintenance jobs shown in the manual of the machine in which the pump is integrated;
unless otherwise indicated, in relation to the pump, remember the following.
mAINTENANCE SCHEDULE
After every use
Every 50 hours
(1)
Checks must be made more frequently if the pump operates where there are strong vibrations.
WARNING
• Special maintenance jobs must only be performed by a Skilled Technician.
• Used oil must be adequately disposed of and not discarded in the environment.
Perform the routine maintenance jobs shown in the manual of the machine in which the pump is integrated;
unless otherwise indicated, in relation to the pump, remember the following.
mAINTENANCE SCHEDULE
Every 500 hours (200 hours for series AX
and BX).
(*)
Checks should be made more frequently if the pump operates where there are strong vibrations.
(**)
The first oil change is best made after 50 hours.
CAUTION
• The data shown on the chart are approximate. More frequent jobs may be necessary in case of particularly
heavy-duty use.
mAINTENANCE

ROUTINE mAINTENANCE

• Check oil level and conditions according to instructions in "P
" paragraph.
ACTIvITIES
• Check the integrity of the suction circuit.
• Check and if necessary clean the suction filter.
• Check the fastening of the pump to the motor to which it is coupled and/or
to the structure of the machine in which it is integrated.
In the event of such fastening being precarious, do not use the machine and
contact a Skilled Technician

SPECIAL mAINTENANCE

• Check the suction/delivery valves.
• Check the tightness of the pump screws
(**)
• Oil change
.
• Check the pressure unloader/regulation valve.
JOb