Summary of Contents for Boss ODOROX

  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety Information ..................1 Contents List ....................2 Odorox® Boss™ Operational Guidelines ............ 3 Operating The Odorox® Boss™ ..............4 Care Instructions ..................5 Optic Replacement Instructions ..............6 Troubleshooting Guide ................7 Specifications And Warranty ..............8...
  • Page 3: Safety Information

    SAFETY INFORMATION WARNING! Use this Hydroxyl Generator only for its intended purpose as described in this Owner’s Manual. PLEASE READ AND SAVE or authorized repair facility for examination, electrical or mechanical adjustment, or repair. THESE IMPORTANT SAFETY INSTRUCTIONS • Use generator only for intended use as described in this manual.
  • Page 4: Contents List

    CONTENTS LIST The Odorox® Boss™ Hydroxyl Generator is shipped with the following: 1. Odorox® Boss™ Hydroxyl Generator 2. Washable Filter (Comes Installed) 3. Set of Keys 4. Owner’s Manual 5. Warranty Card...
  • Page 5: Odorox® Boss™ Operational Guidelines

    The Odorox® Boss™ unit is designed for heavy concentration processing and operates using less than 230 Watts (refer to Specification page for additional ratings). The Boss™ unit is equipped with a selector switch for 1 or 2 Odorox® hydroxyl generating optics and a washable filter. The built-in fan is adjustable from approximately 250 to 500 cfm which makes this unit very versatile.
  • Page 6: Operating The Odorox® Boss

    “OFF” position. FAN SPEED The Boss™ unit is equipped with a fan, which operates at between 250 and 500 cubic feet per minute. In order for the fan to turn on, the FAN SPEED switch must be rotated clockwise.
  • Page 7: Care Instructions

    Interior The interior of the Odorox® product can be cleaned in the same manner as the exterior with the exception of the optics and optics’ housing. OPTIC CLEANING Cleaning of the Odorox®...
  • Page 8: Optic Replacement Instructions

    OPTIC REPLACEMENT INSTRUCTIONS CAUTION: DISCONNECT the unit from an electrical power source before performing any maintenance or cleaning on the unit. Step 1 – Turn “FAN SPEED” switch to the “OFF” position Step 2 – Unplug power cord from the electrical receptacle Step 3 –...
  • Page 9: Troubleshooting Guide

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Fan will not turn on Boss™ unit is not plugged Ensure circuit breaker is into an energized electrical ‘ON’ and the electrical receptacle. receptacle has proper power available. Internal component failure. Contact local distributor for service.
  • Page 10: Specifications And Warranty

    SPEED CONTROL KNOB LIMITED WARRANTY HGI Industries, Inc. warrants that this Odorox® product (excluding spare parts and consumables) shall be free from defects in workmanship or materials for a period of one (1) year from the delivery thereof to the customer.
  • Page 11 Odorox® Hydroxyl Generators are proudly manufactured in the USA. HGI Industries, Inc. 2055 High Ridge Road Boynton Beach, FL 33426 Toll Free: 877.735.3701 www.hgiind.com Copyright © 2011, HGI Industries Incorporated Odorox and Boss are trademarks or registered trademarks of HGI Industries Incorporated, Boynton Beach, Florida USA.