Download Print this page

Sanyo DP50749-02 Service Manual page 3

Advertisement

DP50719-00
DP50749-02
IF YOU BELIEVE THE SMPS IS DEFECTIVE
The SMPS can be checked, but all cables & flat ribbons from the SMPS & Digital Processor PCB
must be unplugged. The only exception is the cable from D25 (D Bd.) to P25 (SMPS) must be
connected. With everything disconnected except this one cable, and when power is applied to
the SMPS, the SMPS should turn ON.
If the SMPS is working OK, please reconnect all connectors to the SMPS & Digital Processor. If
one of the other PCBs is defective, it is possible to damage the SMPS, w/o the flat ribbons
connected to the Digital Processor.
Apply power to the SMPS.
These voltages should be present:
Connector:
P2
p1
193.6
p2
P6
p1
p2
15.5
p3
15.5
p4
p5
p6
p7
p8
15.5
p9
15.5
p10
p11
p12
SMPS & Digital Processor
No cables attached to SMPS or Digital
Bd., except cable from D25 to P25.
P7
p1
p2
p3
p4
p5
5.0
p6
p7
p8
p9
p10
p11
P11
p1
193.6
p2
p3
p4
15.5
P25
p1
15.5
p2
15.5
p3
p4
p5
5.0
p6
5.0
p7
p8
p9
5.0
p10
p11
3.3
p12
p13
P35
p1
60.3
p2
60.3
p3
p4
p#3
12/16/10

Advertisement

loading

This manual is also suitable for:

Dp50719-00