Troubleshooting - Graco InSite 24T280 Instructions Manual

Remote reporting installation kit
Table of Contents

Advertisement

Troubleshooting

Problem
No module status LEDs are illumi-
nated.
Has not identified GPS location
(green module status LED flashing).
Has not established a cellular con-
nection (orange module status
flashing).
Cannot view data for my unit(s) on
website.
Temperature data not displayed on
website.
Hose zone temperature data not
displayed on website.
Pressure data not displayed on
website.
333276A
Cause
No power to cellular module.
Still identifying location.
Unable to identify location. In a
location where GPS lock cannot
occur. Buildings and warehouses
often prevent GPS locks.
Still establishing cellular connection.
Unable to establish cellular connec-
tion.
Graco InSite unit has not been acti-
vated.
Reactor temperature measurement
is not working.
The RTD is not correctly installed
on the hose or is broken.
Reactor pressure measurement is
not working.
Troubleshooting
Solution
Turn Reactor ON.
Ensure unit is properly installed.
See Installation on page 3.
Make sure the M8, 4-pin to M12,
8-pin cable is installed between cel-
lular module and control box.
Wait a few minutes for the unit to
identify the location.
Move system to a location with a
clear view of the sky.
Wait a few minutes for unit to estab-
lish the connection.
Move system to a location with cel-
lular service to establish cellular
connection.
Activate unit. See Registering and
Activating the Graco InSite on
page 4.
See Reactor repair manual.
See Reactor repair manual.
See Reactor repair manual.