The parameters that appear in each one of the four signals are:
Active:
If you tick this checkbox the signal becomes active, that is, the
instrument emits the signal. On the graph you can know what signal
is enabled (dark blue) or disabled (light blue) by the colour.
Frequency:
It defines the frequency you want to emit at (in MHz). It should be
into the range of working values for each signal. It can be defined
numerically by typing the value on the box or analogically by
dragging the marker at the bar.
Level:
It defines the signal power level into the range of possible values. It
can be defined numerically by typing the value on the box or
analogically like the frequency. The measurement unit is selectable
between dBµV, dBm ó dBmV.
At the upper right corner there is a box with information about the connection. If
there is not connection with the RP-110, that box will be disabled. If there is connection,
that box will show data about the model, serial number and firmware version. In this box
it is also the option "Enable Online Modifying Utility".
When you tick the option "Enable Online Modifying Utility", changes made on the
signals through the program are transfered inmediately to the RP-110. If changes are
made with that option disabled, to send the data on the screen, you should have to click
on the option "Send" at the menu program.