Promax RP-110 User Manual page 47

Six rf-tone generator
Hide thumbs Also See for RP-110:
Table of Contents

Advertisement

Available languages

Available languages

USER'S MANUAL. RP-110
At the top of the screen appears a line with the parameters of the selected signal.
In shaded the editable parameter.
Press the key SEL
to edit is shaded.
Press the cursor key UP or DOWN
parameter.
Parameters are:
a) PILOT
It allows you to select the pilot signal from 1 to 6. This arrow at the top of the
graph indicates what is the selected signal. Each pilot signal works in a specific
frequency range. They are the following ones:
P1:
P2:
P3:
P4:
P5:
P6:
b) FREQUENCY
It defines the frequency at which the selected pilot signal is emitted.
Frequencies are divided into three bands:
Upstream channel band: From 5 to 100 MHz.
Downstream terrestrial band CATV: From 55 to 1000 MHz.
Downstream satellite band - IF SAT: From 800 to 2150 MHz.
Página 11
Figure 4.- Main screen.
[3] to move between parameters, until the field you want
5.00 MHz to 10.00 MHz.
55.00 MHz to 100.00 MHz.
460.00 MHz to 540.00 MHz.
800.00 MHz to 1000.00 MHz.
1450.00 MHz to 1750.00 MHz.
1850.00 MHz to 2150.00 MHz.
[4] to change the status of a
10-2010

Advertisement

Table of Contents
loading

Table of Contents