Chapter 7: Software Calibration - Galaxy DX5 Calibration And Maintenance

Epson printhead calibration
Table of Contents

Advertisement

Chapter 7.
Software Calibration
1. Nozzle checking: Print the nozzle checking to check the condition of the printhead.
Make sure to turn off the Eclosion (Feather) function before doing the alignment.
2. Vertical calibration: Observe the physical alignment of printheads.
(This step is not aligned well which will affect the following adjustment)
Align the physical vertical position of printhead.
The first pass line is the reference; observe whether the second pass line is perfectly aligned with the first
pass line. If not, then we need to adjust the carriage plate. There are 3 situations:
1) The two pass is perfectly aligned, no need to adjust:
Second pass
First pass
2) The second is on the left side of the first pass:
Second pass
First pass
Adjust method:
A. Loosen the 3 screws on the carriage plate:
B. Turn the screw clockwise:
10