Model
E32-TTL-100
E32-TTL-100S1
E32-T100S2
E32-TTL-500
E32-TTL-1W
E32-433T30S

2.2 Electrical Parameters

2.2.1 Transmitting current

Model
E32-TTL-100
E32-TTL-100S1
E32-T100S2
E32-TTL-500
E32-TTL-1W
E32-433T30S

2.2.2 Receiving current

Model
E32-TTL-100
E32-TTL-100S1
E32-T100S2
E32-TTL-500
E32-TTL-1W
E32-433T30S
Copyright ©2012–2017, Chengdu Ebyte Electronic Technology Co., Ltd.
Core IC
SX1278
SX1278
SX1278
SX1278
SX1278
SX1278
Min
Typ
Max
100
110
120
100
110
120
100
110
120
390
410
450
570
610
670
520
550
610
Min
Typ
Max
13
14
13
14
13
14
19
20
19
20
22
23
Net weight
Size
6.7±0.1g
21 * 36 mm
17 * 25.5 mm
1.6±0.1g
17 * 30 mm
1.6±0.1g
24 * 43 mm
8.2±0.1g
24 * 43 mm
8.2±0.1g
25*40.5mm
5.2±0.1g
Unit
mA
When designing current supply circuit, 30% margin is
recommended to be remained so as to ensure long-term
mA
stable operation of the whole module;
The current at the instant of transmitting may be high,
mA
but the total energy consumed may be lower due to very
short transmitting time;
mA
When using external antenna, the impedance matching
degree at different frequency points between antenna and
mA
module may affect the transmitting current value at
different levels.
mA
Unit
15
mA
The current consumed when the RF chip is only working
15
mA
at receiving mode is called as receiving current, the tested
receiving current may be higher for some RF chips with
15
mA
communication protocol or the developers have loaded
their own protocol to the whole module.
22
mA
The current at pure receiving mode will be mA level, the
users have to realize µA level receiving current through
22
mA
firmware development.
25
mA
E32 Series User Manual
Operating
Operating
temperature
humidity
-40 ~ 85℃
10% ~ 90%
-40 ~ 85℃
10% ~ 90%
-40 ~ 85℃
10% ~ 90%
-40 ~ 85℃
10% ~ 90%
-40 ~ 85℃
10% ~ 90%
-40 ~ 85℃
10% ~ 90%
Remarks
Remarks
Storage
temperature
-40 ~ 125°C
-40 ~ 125°C
-40 ~ 125°C
-40 ~ 125°C
-40 ~ 125°C
-40 ~ 125°C