The wire which is coloured GREEN AND YELLOW must be connected to terminal
which is marked with the letter "E" or by the Earth
or GREEN AND YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is mar-
ked with the letter "N" or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is
marked with the letter "L" or coloured RED.
5H¿W WKH FDEOH FODPS VR WKDW LW FODPSV WKH RXWHU VOHHYLQJ RI WKH FDEOH DQG VFUHZ WKH
screws "C".
5H¿W WKH FRYHU SODWH ³B´ DQG ¿[ LW ZLWK WKH VFUHZ ³A".
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac
FEEDER CABLE SECTION
This double oven must be connected to electrical supply using V105 insulated cable.
2
3 x 2.5 mm
(*)
(*) Connection with wall box connection.
Figure 4
A
4770 W (20.73 A)
B
symbol or coloured GREEN
Figure 5
Brown (Live)
Blue (Neutral)
P
C
L
N
E
L
1
N
PE
1
(L
)
2
(L
)
2
N
L
D
Green & Yellow
(Earth)