30L/38L SILENT OIL FREE AIR COMPRESSOR
Regulator knob has
continuous air leak
Regulator will not shut
off air outlet
Moisture in pump
crankcase
Motor will not run

ENVIRONMENT PROTECTION

Waste electrical products should not be disposed of with household waste. Please recycle
where facilities exist. Check with your Local Authority or retailer for recycling advice.
Hole in air hose
Check valve restricted
Air leaks
Restricted air intake filter
Regulator is damaged
Regulator is damaged
Unit operating in damp or humid
conditions
Check valve restricted
Motor overload protection switch
has tripped
Loose electrical connections
Possible defective motor or
starting capacitor
Fuse blown, circuit breaker
tripped
Tank pressure exceeds pressure
switch cut-in pressure
Pressure release valve on
pressure switch has not
unloaded head pressure
15
Replace air hose.
Remove, clean or replace.
Tighten fittings.
Change air intake filter.
Replace.
Replace.
Move unit to a dry well-ventilated
area.
Remove, clean or replace.
Let the motor be cooled to lower
the temperature
Contact an authorized service
center.
Contact an authorized service
center.
Check fuse box for blown fuse and
replace as necessary. Reset circuit
breaker. Do not use a fuse or
circuit breaker with higher rating
than that specified for your
particular branch circuit.
Check for proper fuse. Use only a
time delay fuse.
Check for low voltage conditions
and/or proper extension cord.
Disconnect the other electrical
appliances from circuit or operate
the air compressor on its own
branch circuit.
Motor will start automatically when
tank pressure drops below cut-in
pressure of pressure switch.
Set the pressure switch to off. If the
valve does not open, replace
switch. Contact an authorized
service center.