30L/38L SILENT OIL FREE AIR COMPRESSOR
10) Turn the power switch to the off position and disconnect the plug from the receptacle after your
work is finished.
Warning: Many components such as air compressor head, motor, and tubing will remain
hot even after the air compressor has been shut down. Allow air compressor to cool before
moving or attempting maintenance.
9. Motor Thermal protecting
If your air compressor is overload, the air compressor may suddenly stop working. That is the inner
thermal parts work because of over-loading. Under this circumstance, no need to turn off the power
switch. Start the air compressor automatically after the motor be cooled to lower the temperature.
10. Draining Tanks
1) Place the air compressor on a level surface. If air compressor is not level, water will not drain from
tanks causing corrosion, which may cause the tanks to burst.
2) Use air cock to reduce tank pressure.
WA
Warning: Do not open drain valve with pressure greater than 0 psi in tanks. Such
precautionary measures reduce the risk of injury.
3) Open the drain valve on bottom of tank counterclockwise. After the water has been drained, close
the drain valve by clockwise. The air compressor can now be stored.

MAINTENANCE

Your air compressor requires periodic maintenance, in order to keep your air compressor in peak
condition.
Warning: Remove the plug from the socket,drain air tanks and allow it to cool before
making adjustments, moving the air compressor, leaving the work area, performing
maintenance or storing the air compressor.
1. Check safety valves by pulling on rings daily.
2. Drain moisture from tanks daily or after each use daily.
3. Clean the cooling surfaces of the air compressor with damp cloth weekly.
4. Check system for air leaks by applying soapy water to all joints monthly. If leaks are found in the air
compressor pump, air tanks or tubing, replace air compressor immediately. Never attempt repair leaks,
weld or make modifications to the air tank or other fluid confining parts as there is a risk of bursting.
5. Change the air filter every 200 hours.
6. When not in use, the air compressor should be disconnected and stored in a warm and dry place.
Coil the electric cord and place within frame for protection.
7. Check all cords periodically. They must be in good condition and not cracked. If the cord is damaged,
it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid
a hazard.
13