lancer MB-18 Installation And Service Manual

High volume free standing fountain drink dispenser

Advertisement

Quick Links

INSTALLATION AND SERVICE MANUAL
MB-18, HIGH VOLUME FREE STANDING
FOUNTAIN DRINK DISPENSER
SPECIFICATIONS
DIMENSIONS
Width
Depth
Height
To Countertop
To Top of Shroud
WEIGHT
Shipping
Empty
Operating
ELECTRICAL
Operating Voltage
Hertz
Amps
This initial (draft) issue is released for field test purposes ONLY!!!
• USA -CANADA – 210-310-7250 • LATIN AMERICA – 210-310-7245 • ASIA – 210-310-7242
"Lancer" is the registered trademark of Lancer
FOR THE
Part Number 85-10018-126, 115 Volts, 60 Hz
36 inches (91.4 cm)
36 inches (91.4 cm)
36 inches (91.4 cm)
61 inches (154.9 cm)
600 pounds
530 pounds (240 kg)
800 pounds (363 kg)
115
60
20
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
• EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978
FAX ENGINEERING: • 210-310-7096
(272
kg)
FAX SALES
Copyright — 2001 by Lancer, all rights reserved.
Check out the Lancer web site:
www.lancercorp.com
DATE:
06/18/01
P.N.
28–0466

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MB-18 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for lancer MB-18

  • Page 1 Amps This initial (draft) issue is released for field test purposes ONLY!!! 6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000 FAX SALES • USA -CANADA – 210-310-7250 • LATIN AMERICA – 210-310-7245 • ASIA – 210-310-7242 •...
  • Page 2: Table Of Contents

    The MB-18 features multiple speed ice dispense from an under counter ice storage bin which is also used to chill the product utilizing a flexible, high performance cold plate system. Up to 18 independent brands may be dispensed through six (6) Lancer Multi-Flavor dispense nozzles.
  • Page 3: Installation

    NSF standards. A backflow prevention device must comply with ASSE and local standards. It is the responsibility of the installer to ensure compliance. A. General Product Configuration 1. The MB-18 is equipped with nine (9) independent soda/water inlets (see Figure 1 for detail).
  • Page 4: Electric Power Supply

    B. Drain Connections The MB-18 Features two (2) 3/4" MPT connections on the left side (from the front) of the machine for the cold plate drain system and a third (3rd) 3/4" FPT fitting for the drip tray drain located on the right hand side of the machine. The cold plate drains should be plumbed independent from the drip tray drain and adequate slope and air gap should be provided to prevent back up and potential contamination.
  • Page 5: Periodic Maintenance, Checklist And Cleaning Guide

    Small brush. d. Extra nozzle. e. Sanitary gloves. PERIODIC MAINTENANCE, CHECKLIST AND CLEANING GUIDE A. CLEANING AND SANITIZING THE LANCER MB-18 1. CLEANING PROCEDURE NOTE: This procedure should be accomplished on a daily basis, or more often (if required).
  • Page 6: Cleaning And Sanitizing Beverage Components - Figal Systems

    Fill Unit with ice and replace Top Cover. NOTE Lancer does not recommend the use of shaved, flake, nugget, or pellet ice in the dispenser. Dispenser will only operate properly with cube ice. m. Reconnect Dispenser to power source and check for proper functioning.
  • Page 7: Cleaning And Sanitizing Beverage Components - Bag-In-Box Systems

    WARNING TO AVOID POSSIBLE PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT ATTEMPT TO REMOVE SYRUP TANK COVER UNTIL CO PRESSURE HAS BEEN RELEASED FROM TANK. D. Disconnect CO supply hose from the water filled syrup tank. E. Following the instructions as described in Section 2.1 above, mix appropriate amount of cleaning solution.
  • Page 8: How To Operate The Lancer Mb-18

    U.V.W. Lancer reserves the right to make changes and updates as required. If you have any questions regarding the latest versions of programs, please contact your Lancer representative. 1. The Lancer MB-18 is equipped with a serial communication port to facilitate set up, data retrieval and maintenance. In addition an infrared wireless port is available.
  • Page 9 Select the UPDATE button after changing the parameter to load the setting into the MB-18. You will be prompted to verify your change prior to the change becoming active. Select OK to accept the changes or CANCEL to return to the previous menu.
  • Page 10: Troubleshooting Guide

    0.025 seconds for diet (thin) syrups to as much as 0.125 seconds or 0.150 seconds for very thick syrups (Big Red). The adjustment criteria are by visual inspection of the flow stream during a pour cycle. 4. MB-18 TROUBLE SHOOTING GUIDE TROUBLE CAUSE...
  • Page 11: Auger Assembly

    (Continued from previous page) AGITATOR MOTOR ASSEMBLY (CONTINUED) PART NO. DESCRIPTION QTY/UNIT COMMENTS 04-0520 SCREW, 1/4-20 X .50 MOUNT MOTOR 10-0463 COUPLING, AGITATOR 10-0479 PIN, AGITATOR COUP. AUGER ASSEMBLY 05-1805 CAP, AUGER TUBE, BTM 05-0823 BEARING, AUGER 04-0310 SCREW, 8-16 X .62 MOUNT BEARING TO CAP 27-0073 TUBE, AUGER...
  • Page 12: Shroud Assembly

    12-0303 SOCKET, POWER RELAY 12-0363 RELAY, POWER 10-0473 PROP ROD 04-1259 EYBOLT 05-1280 BUMPER Check out the Lancer web site: SHROUD ASSY www.lancercorp.com 52-2349 PCB ASSY, INTERCONNECT 05-1535 SUPPORT, PCB 12-0413 SWITCH, 6 PROD, MB18 12-0414 SWITCH, 3 PROD, MB18...

This manual is also suitable for:

85-10018-126

Table of Contents