• Carefully shut off both hot and cold main water supplies. • Pioneer reserves the right to make changes in the design of faucets without notice as specified in the pricebook. Caution: These products may cause personal injury due to scalding if the temperature is set too high. We recommend that temperature is set below 120 °...
Valve Installation Determine the location of the valve. Install the required support framing. Determine the distance to set valve to the recommended depth based upon the lines provided for desired trim. These lines designate where the installed valve should be flush with the finished wall. Improper installa- tion may result in performance and aesthetic issues with the product. Remove inlet stop assembly, test cap before soldering.
Page 5
Valve Installation Install hot and cold water supplies (C&D) using 1/2” iron pipe, copper to copper, CPVC or PEX connections. Connect 1/2” pipe nipples (E&F) to bath and shower outlets. Replace the inlet stop assembly and test cap. While replacing the inlet stop do not tighten more than 5lbs/inch .
Page 6
For thick or thin wall installation refer to the drawings and to Step (1). For more care information or trouble shooting inquiries about your Pioneer Product, please see the contact information on the back page. REV-12 18, 12...
Page 7
Engineering Excellence Engineering E xcellence 3325 S. Garfield Ave. | Commerce, CA 90040 Telephone: (800) 338-9468 | (323) 888-8873 | Fax: (323) 888-9515 Hours: M - F, 7:30am to 5:00pm PST www.pioneerind.com REV-12 18, 12...