'' DOUBLE LIGHT '' SERIES FOR NON-MAINTAINED LUMINAIRES
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)
BATTERY PROTECTION
INDICATIONS - CONTROLS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
FLUORESCENT LAMP
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
These luminaires are used in places where
emergency luminaires are needed.
Each luminaire must be permanently connected to
mains power supply.
In normal operation the battery is charging and the
2 yellow LED's light in the screen.
In case of a mains power supply failure the
luminary
will
light the lamp
emergency mode.
supply
is
restored the device turns to normal
operation.
ÁÔÔÅÍÔÉÏÍ!!!
1. Operations for installation, maintainance or
testing must be done by authorized personel only.
2. The device must be connected to the mains
power supply thru a fuse dependent by the total
amount of the line's power load.
3. It is sugested to check every month the
indication LED for battery charging, and by pushing
the TEST button to check the emergency cirquit.
The lamp should light as long as the TEST button
is
pressed. In the opposite condition contact the
installer.
1. Detach the plastic base (located in the bottom of the luminaire) by pulling the unlock hook and pass the cables
thru the respective hole. Mount the plastic base with the included mounting accessories.
2. Connect the cables to the terminal blocks as showed.
3. Attach the luminaire by sliding it on the plastic base until the plastic hook locks, and power the luminaire.
230V AC
L
N
Cables
pass thru
hole
automatically in
When the
mains
Plastic base
EM 2771
220-240V AC/50-60Hz
3 VA
2.4V/1.5Ah
From full discharge
Battery charging LED, TEST button
90min
EN 60598-1, EN 60598-2-22
Bayblend FR3010, transparent polycarbonate
332 x 100 x 205 mm
770gr.
3 years (1 year for the lamp and the battery)
4. It is sugested to check every 6 months the
minimum autononous duration by disconnecting the
mains power supply. Count the time that the lamp
lights and in case of less time than the minimum
autonomous duration the battery must be replaced.
If the measured time is considerably less than the
minimum autonomous duration
In case of battery or lamp replacement, these must
be replaced by parts of the same type
power
5.
It is sugested
hours of continuous operation
failures of mains power supply reduces dramaticaly
the lamp s life time
'
6. In case of inactive use for a period greater than 2
months, disconnect the battery by pulling out the
battery's connector.
7. I
t i
s not allowed to discard batteries in to
common trash bins, they must be discarded
only
in battery recycling points. Do not
incinerate.
INSTALLATION
To install the luminaire follow the installation
instructions bellow.
EM 2772
4 VA
2.4V/3Ah
24h
3h
8W (T5)
85lm
IP 20
o
0 to 40 C
Up to 95%
870gr.
contact the installer.
to replace the lamp every 8000
.
.
923512000_09_004
.
The frequent
Lock - unlock hook

Advertisement

loading

Summary of Contents for OMS Double Light Series

  • Page 1 ‘’ DOUBLE LIGHT ‘’ SERIES FOR NON-MAINTAINED LUMINAIRES EM 2771 EM 2772 TECHNICAL CHARACTERISTICS OPERATION VOLTAGE 220-240V AC/50-60Hz MAXIMUM POWER CONSUMPTION 3 VA 4 VA BATTERIES (Ni-Cd) 2.4V/1.5Ah 2.4V/3Ah BATTERY PROTECTION From full discharge INDICATIONS - CONTROLS Battery charging LED, TEST button CHARGING TIME MINIMUM AUTONOMOUS DURATION 90min...
  • Page 2 ‘’ DOUBLE LIGHT ‘’ SERIES FOR MAINTAINED LUMINAIRES EM 2774 EM 2775 TECHNICAL CHARACTERISTICS OPERATION VOLTAGE 220-240V AC/50-60Hz MAXIMUM POWER CONSUMPTION 23 VA 24 VA BATTERIES (Ni-Cd) 2.4V/1.5Ah 2.4V/3Ah BATTERY PROTECTION From full discharge INDICATIONS - CONTROLS Battery charging LED, TEST button CHARGING TIME MINIMUM AUTONOMOUS DURATION 90min...

This manual is also suitable for:

Em 2771Em 2772