SAFETY Safety precautions This equipment is normally used or connected to circuits that may employ dangerous and lethal voltages. Extreme caution should be exercised by operating or maintenance people when working on or with this equipment. See IEC 61820 & 61821 standard (CCR type IEC), or FAA AC150/5340-26 advisory circular (CCR type FAA), concerning safety rules and precautions.
Page 8
ABBREVIATIONS Abbreviation Definition Ampere Alternating Current Brightness Constant Current Regulator Direct Current High Voltage Isolation Transformer Lamp Fault Detector Low Voltage Out of order Volt Volt-Ampere 6021742 DIAM 3200 1 to 2,5KVA rev 1-0.doc...
MECHANICAL DESCRIPTION I.2.1 DESCRIPTION Each CCR is housed in a cabinet fitted with removable lifting rings. The frame has two distinct parts: a control part (in front) and a power compartment (at the back). The Control part of the CCR contains all the components connected to the power supply with, for example, the mother board and associated driver boards, the master switch, the LV breaker and connection terminals.
I.3.3 GENERAL ELECTRICAL FEATURES Power supply voltage: Single phase: 220, 230, 240, 380, 400 or 415 Vac, +/-10% (IEC), 50/60Hz. Maximum rated current: 6.6 A Number of Brightness Levels: maximum 8, adjustable. Heating Brightness (“Black current”): The CCR can produce “heating”...
Alarms and Warnings: Alarm : (the CCR failed to supply the load); for example, the CCR is stopped by a loop open circuit : ALARM: I<<Open Cir. reset Cancel fault(s) Warning : (the CCR doesn’t stop; warning is only indicative); It is the case for EFD and LFD faults. Alphanumeric display: VFD display (16 x 140 pts) : upper text provide data information, and lower text the key definition.
I.4.1 CONFIGURATION SOFTWARE UTILITY A software has been developed to set all parameters in the CCR. This software named ALIZE4100 can be download using the following link: http://www.augier.com/soft/ALIZE4100.exe 6021742 DIAM 3200 1 to 2,5KVA rev 1-0.doc I-18...
I.5.1 CONFIGURATION The “Configuration” menu is used to define the basic parameters of the CCR (for example when replacing the main board): Rated mains voltage in Vrms: 240 Rated power in KW : 2.5 Number of brightness (Including B0): from 1 to 8 ...
OPTIONS I.6.1 EARTH FAULT DETECTOR (EFD) This option is used to measure the insulation of the load with respect to earth. The insulation controller, or “earth fault detector” continually checks the electrical resistance between the loop and earth. It uses the principle of continuous current injection at 500V and its range of measurement is between 1 k...
Press OK to start initialisation. The message “ Wait please...” flashes meaning that data collection is in progress. When the message stops flashing, data collection has been completed. The number of fault lamps can be seen in the “Monitoring” menu Two comparison levels (warnings level 1 &...
II.1.3 DEVICE LOCATION In deciding the permanent operating location for the device, the following points must be kept in mind: An easy access must be kept to the front door with no obstruction. CCRs can be placed side-by-side, or stacked one on top of the other. ...
II.2 CONNECTIONS II.2.1 POWER AND EARTH N.B.: before making any connections, make sure the installation is turned OFF. II.2.1.1 LV supply: Connection to the mains is made at the rear of the CCR, by mean of the two screw terminals. The power cable run through the hole.
II.2.2 REMOTE CONTROL CONFIGURATION Connections to the control system is made at the front of the CCR: II.2.2.1 Connectors: ETHERNET 1 ETHERNET 2 (OPTION) (OPTION) JBUS RS485 2 JBUS RS485 1 (OPTION) (STANDARD) SOURIAU CONNECTORS (OPTION) FOR ALL REMOTE INFORMATION, SEE NOTICE 6021732. 6021742 DIAM 3200 1 to 2,5KVA rev 1-0.doc II-30...
II.3 ADJUSTING THE CCR II.3.1 MULTI TERMINAL INDUCTANCE Inductance is in the CCR to filter the input current. It is placed at the rear of the CCR. Multi terminal inductance The inductance has 3 values available (L0, L1 and L2). L0 (the lower value) is selected by default. Depending of the loop load, the output current can be unstable.
See paragraph I.5.2 If the CCR does not supply the desired current, either it is in overload or the load contains transformers with open secondaries (missing or burnt lamps) II.3.2.3 Value of “Open Circuit” protection level: See paragraph I.5.3.2 II.3.2.4 Value of “Overcurrent”...
COMMISSIONING After that all installation operations defined in the previous section have been completed, the DIAM3100 CCR can be commissioned. III.1 PROCEDURE 1. Set the tapping as shown in § Erreur ! Source du renvoi introuvable. 2. Close the fuse box master switches 3.
MAINTENANCE IV.1 FORMALISATION To follow maintenance procedures correctly, the following points must be observed: Create a maintenance file containing the headings “Date”, “Time”, “Maintenance Engineer”, “CCR reference”, “Problem definition”, “Solution applied”, and “Time spent” The spare parts monitoring sheet (with their control numbers) should be completed if necessary. ...
IV.3.1.1 In front of the CCR Measurement board Daughter board Main switch EFD board Cut out plate Mother board Interface board EMI filter board Circuit breaker 6021742 DIAM 3200 1 to 2,5KVA rev 1-0.doc IV-40...
IV.3.2 FAULT DIAGNOSIS See paragraph I.5.3 for a description of the following protections. IV.3.2.1 LV power fault: Symptom Fault Action The CCR has stopped LV power fault Check the voltage level of the LV power supply The message: Check parameter settings in the “Configuration”...
IV.3.2.4 Other faults Symptom Fault Action Output current insufficient Large number of ITs open Check the number of ITs open due to missing or fault lamps The message CCR power insufficient Check that the installed power “Warning: Regulation error” is not greater than the power of the CCR is displayed Display remains off when CCR is...
IV.4 SPARE PARTS LIST STACKABLE STANDARD CABINET Input CABINET Designation volatge 1 kVA 2,5 kVA 2,5 kVA 5 kVA 7,5 kVA 10 kVA 15 kVA 20 kVA 25 kVA 30 kVA IC60N IC60N IC60N 40A IC60N 63A C120N C120N IC60N 6A C IC60N 16A C NSX 160 F TM160D 220/240V...
STACKABLE STANDARD CABINET Input CABINET Designation volatge 1 kVA 2,5 kVA 2,5 kVA 5 kVA 7,5 kVA 10 kVA 15 kVA 20 kVA 25 kVA 30 kVA Power board 30.11637 Daughter board 30.11412 Measurement 30.08004 board Remote control SEE NOTICE 6021732 220/240V 30.10087 EMI board...