Page 3
HEATER RESET CONTINUED ..................49 WATER REFRIGERATION SYSTEM ................50 HAZARDS ..........................51 VIEW OF CONTROL PANEL ..................... 52 BOTTLE PROBE CHANGE ....................53 SERVICE CHECKLIST ......................54 EMC DIRECTIVE STATEMENT ..................55 APPENDIX ..........................56 FLOW DIAGRAM ........................57 INDIVIDUAL STAGES AS PER THE LADDER DIAGRAM ...........
If it has been tipped or dropped do not accept delivery of equipment! Remove the product from its packaging. Any damage please notify immediately. Crate should comprise of: 1. S90 Pasteuriser, Two Hoses (Hot and Cold) & 2 Baskets (depending on order) 2. SD Card and reader 3. Spare Probe 4.
SPACER FITTING INSTRUCTIONS The pasteuriser is supplied with spacers; these must be fitted to ensure correct space is around the pasteuriser. Once fitted please send photo’s via email to salesadmin@sterifeed.com, if spacers are not fitted it will invalidate the warranty.
• Run a minimum of 1 test cycle with a full load before putting machine into operation and forward the graph of this cycle to Sterifeed (support@sterifeed.com) for a health check. See operator manual pages 19-22 • Place the thermometer near the machine to monitor the temperature and place the warning poster above the pasteuriser.
Failure to observe these instructions may invalidate your right to free service during the guarantee period. Recommended: Heat extractor if the room has a high ambient room temperature. Pasteuriser Heat output during cooling for the S90 = 2.772kWh Pasteuriser ambient operating temperature: 5˚C to 25˚C Page No.8...
ELECTRICAL CONNECTIONS - CONT ELECTRICAL CONNECTIONS Supply AC only. The machine must not be used on DC supply. Earthing warning - this appliance must be earthed. The manufacturer declines any liability should this safety measure not be observed. Electrical connection - important: The unit is supplied with a 13A plug which must be plugged into a corresponding switch socket of the same type.
WATER OUTLET CONNECTION The drain hose should discharge into an air gap standpipe between 600mm & 900mm above floor level. Details are shown below. Note the hose must fall continuously from the back of the unit to the standpipe. WATER SUPPLY Water consumption: 85 Litres per cycle Warning: Maximum incoming hot water temperature is 55˚C (If higher, a temperature regulator will...
INSTALLATION PHOTOS Pictures to show how hot and cold water and drainage should look Page No.11 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
SCREEN CALIBRATION To calibrate the screen to the operator’s touch first, press and hold the screen for 7 seconds. Press and hold here Press on the calibrate screen button. On the next screen press on the ‘yellow squares’ as they appear, once last square disappears the screen will then be calibrated.
SD CARD SOFTWARE INSTALLATION Before installing SD Card software, disable UAC (User Account Control) as described below if running Windows Vista, Windows 7, windows 8 or Windows 10. Note - You’ll need to reboot your computer before the changes take effect. Page No.13 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool...
SD CARD SOFTWARE INSTALLATION – page 2 Note - You’ll need to reboot your computer before the changes take effect. Page No.14 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
SD CARD SOFTWARE INSTALLATION – page 3 Disabling UAC in Windows 8 1. Right-click on the “Start” button where you will find the option Control Panel. Click on the “control Panel” and it will take you to the Control Panel Menu. 2.
SD CARD SOFTWARE INSTALLATION – page 4 Disabling UAC in Windows 8 Continued 4. Then click on “Change User Account Control Settings” 5. Here you see “Always notify” scale to the left side. Bring the cursor of the scale to the lowest level to disable the User Account Control in your system and click “OK”...
SD CARD SOFTWARE INSTALLATION – page 5 Disabling UAC in Windows 10 1. Right-click on the “Start” button (The windows symbol) where you will find the option Control Panel. Click on the “control Panel” and it will take you to the Control Panel Menu 2.
SD CARD SOFTWARE INSTALLATION – page 6 Disabling UAC in Windows 10 Continued 6. If prompted by UAC, click on Yes to continue. Note - You’ll need to reboot your computer before the changes take effect. Page No.18 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
SD CARD SOFTWARE INSTALLATION – page 7 1. Place SD card into the card reader on the PC. 2. Click on ‘open folder to view files’ 3. Double click on ‘Set up.exe’ 4. The screen will display the following. Page No.19 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019...
SD CARD SOFTWARE INSTALLATION – page 9 7. Click on ‘I Agree’ and then on ‘Next’ 8. Click on ‘Next’ to start the installation Page No.21 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
SD CARD SOFTWARE INSTALLATION – page 10 9. Installation is complete, click on ‘Close’ For Windows 8 & 10 you will need to do the following: 1. Right click on the Unitronics short cut which is on your desktop now. 2.
SD CARD SOFTWARE INSTALLATION – page 11 3. Click on the Compatibilty tab. 4. Then tick the “ Run this program as an administrator”. 5. Then click on “ Apply” and then click on “OK”. Page No.23 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
MAINTENANCE SECTION – This section is for trained engineers only CONFIGURATION SCREEN If an alarm is active this Icon will flash in the configuration screen. Home This button is the Home button; it will take you back to the screen Finish cycle Button , pressing this will force all the machine to end a cycle and then drain.
CONFIGURATION SCREEN – PAGE 2 Cycle configuration Screen This Button will take you to the where you can set the cycle settings. Help Menu this will display a cut down version of the manual. Level calibration screen Levels Button, This will take you to the Languages, from here you can select different languages from the Language select Screen Temperature probe calibration button, this will take you to the...
LEFT SIDE VIEW OF INTERNAL COMPONENTS High Gas Pressure Fan Control Pressure Switch 421114-01 Switch 421331-01 Low Gas Pressure Switch 421036-01 Liquid Liquid Line Drier 421408-01 Line Solenoid 421219-01 Page No.29 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
FAULT FINDING THIS COLUMN IS FOR ENGINEERING USE ONLY Heater Trip The Heater Circuit Breaker F2 has tripped. PLC Input I1 Check the circuit to establish whether the heater has failed, if there is a loose connection and check the circuit breaker or side mounted auxiliary is faulty. Compressor Trip The Compressor Circuit Breaker F1 has tripped.
Probe Fault Check temperature probe wiring and TC to 4-20mA converter (Y1) operation. PLC Input I6 Replace the probe or converter. S90 not heating up Perform heater reset as per Maintenance section of this manual. Not reaching Check levels. temperature during Check bottle probe is not damaged.
FAULT FINDING CONTINUED Power Failure Alarm Power was removed from machine during cycle ensure power is always switched on to machine. When the play symbol is There is a glitch that happens when a cycle setting is changed. When this pressed the machine happens the tick button needs to be pressed on the PID page, this solves the goes straight into the...
ALARM RESET INSTRUCTIONS PAGE 2 3. Press reset if it doesn’t reset then press the magnifying glass button again 4. Then press the “Ack” button to acknowledge the fault. Page No.36 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
ALARM RESET INSTRUCTIONS PAGE 3 5. Press ESC and this will take you to the previous page. 6. The fault will clear as long as the problem has been solved. If it is still alarming the reset button will need to be pressed as well. This should clear the fault and you can return to the main screen.
MAINTENANCE GUIDE General The pasteuriser will require little maintenance, however the following Checks should be made every six months. Check the lids to ensure it sits correctly when closed. Check that the seal is in good condition. Replace the seal if necessary. Check the lids magnets for superficial damage.
WATER LEVEL SET UP Make sure the SD card has been removed from the machine before proceeding! and type in ‘sterifeed’ in lower 1. From the home screen press on the password button case and press enter. You will return to the home screen.
WATER LEVEL SET UP – PAGE 2 1. From the level screen enter the level values by pressing on the value window for each of the following: (Measured in mm). o Over Level [Default 245 +5/-5] o High Level [Default 225 +5/-5] o Double Storey Neck Level [Default 220 +0/-5] o Single Storey Neck Level [Default 165 +0/-5] o Low Level [Default 130 +5/-5]...
DRAIN TIME CONFIGURATION This page will allow the configuration of the drain timer, this timer allows you to set the time on the drain, this will be the time the drain process needs to continue after the water level has passed the sensor level to ensure its completely drained. Example: when auto drain is pressed or the tank empties but does not fully empty this setting will increase the drain time, the unit does not rely on a timer to move between levels but only when the level is below the sensor level where it cannot take a reading,.
Make sure the SD card has been removed from the machine before proceeding! 1. Place the probe into the bath (without the probe bottle) along with a external calibrated thermometer and type in ‘sterifeed’ in lower 2. From the home screen press on the password button case and press enter.
Page 43
Press the full stop button to drain unit 10. Press the back button to return to the temperature calibration screen 11. From the temperature calibration screen press the low temperature calibration button Note: The low temperature calibration screen can also be used to perform a fridge test. Please also note that the compressor once it has reached 2°C will not come back on until the chill set point is reached.
CYCLE SETUP Make sure the SD card has been removed from the machine before proceeding! and type in ‘sterifeed’ in lower 1. From the home screen press on the password button case and press enter. You will return to the home screen.
CYCLE SETUP – PAGE 2 6. From this second screen enter the cycle 2 values by pressing on the value window for each of the following: o Heating Set Point [Default 62.5°C] o Chill Set Point [Default 3°C] o Cycle 2 Time [Default 30 Minutes] o Cycle 2 Diff [Default 1 Minute] 7.
CYCLE SETUP – PAGE 3 During the auto tune operation you will see this icon appear on the screen, and disappear when finished. To set the rapid heating stop points, press on the valves against the labels ‘LMC1 & LMC2’ o Cycle 1 (LMC1) Default 61.5°C o Cycle 2 (LMC2) Default 61.5°C Press this button to take you back to the Configuration screen.
PARAMETER LIST Description Default Units Minimum Maximum Value Value Value C1 Past. Temp 62.5 50.0 68.0 °C The temperature at which the bath is maintainted during pasteurisation on cycle 1 C1 Past Time (1) minutes The time of pasteurisation in cycle 1 C1 Chill Temp 10.5 °C...
HEATER RESET The heater on the S90 pasteuriser has 2 manual reset safety thermostat. To reset the thermostat follow this procedure: Thermostat • Ensure the power is off • Remove the front panel of the pasteuriser • Remove the right hand side panel •...
HEATER RESET CONTINUED Thermostat After the 1 thermostat has been reset then reset the 2 Thermostat. • Above the heater there is a red button press this to reset the 2 thermostat. • Place the panels back on the pasteuriser. The only other possible cause of the heater not working is that the SSR (solid state relay) mounted in the bottom of the control panel is not operating.
WATER REFRIGERATION SYSTEM From the Flow Diagram in the appendix the circuits can be clearly seen. The water circuit can be repaired and adjusted by a skilled fitter or electrician. The refrigeration system requires a specialist. However, there are certain checks which can be made to determine refrigeration fault.
HAZARDS Electric Shock Medium voltage is present within the cooler. All voltage paths are insulated but the following must be observed: • Do not remove panels without first isolating the cabinet electrically. • Only a qualified electrician should carry out electrical work on the system.
BOTTLE PROBE CHANGE If the bottle probe needs to be changed, the procedure is as follows: 1. Switch off pasteuriser. 2. Remove probe cable from the side panel clips. 3. Remove right hand side panel. 4. Unplug probe from internal socket. 5.
Cullompton Devon EX15 2BB Serial No of Tel: 01884 266 666 Pasteuriser/Date: Fax: 01884 266 333 email: support@sterifeed.com www.sterifeed,com Engineer: Date: Write down the parameters & record last faults Check lid and seal and replace if required. Check lid magnet for damage - change if necessary...
EMC DIRECTIVE STATEMENT With Reference to the EMC directives, the following points are made • All components used in Refcool panels are CE marked • All control panels are manufactured and tested using “Best Practice” methods and sound engineering techniques. Refcool are ISO 9000 certified. •...
EC DECLARATION OF CONFORMITY EC Certificate To be added here Provided by Refcool Page No.70 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
ELECTRICAL TEST CERTIFICATE Electrical Test certificate To be added here Provided by Refcool Page No.71 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
CERTIFICATE OF COMPLIANCE Certificate of Compliance added here supplied by Sterifeed Page No.72 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
TEST GRAPH Graphs to be added here Page No.74 y:\pasteuriser\pasteuriser \manuals 2019\s90refcool Date Printed: 03/12/2019 manuals manuals\s90installation-maintenance pasteuriser manual 3.12.2019.doc...
Cullompton EX15 2BB England Tel: 0044 (0) 1884 266 666 Fax: 0044 (0) 1884 266 333 www.sterifeed.com E-mail: info@sterifeed.com WARRANTY The company hereby warrants subject to the Clauses 7.2, 7.3, 7.4 and 7.5 hereof that each new product or part manufactured by the Company and supplied under this Contract shall be free from defects in material and workmanship.