b. Closing Time:
The setting button is turned clockwise or
counterclockwise until the closing led is turned to
the side to make the setting in the desired group.
When the led turns on, the last set time is
displayed on the screen. Once the setting button is
pressed, the minutes digit of the closing time starts
flashing. While the minute is flashing, turn the
setting dial clockwise or counterclockwise to set
the desired time. Each move of the button gives 5
minutes of change. Press the button once after
setting the desired time allows the setting to be
completed and saved.
2- Manual On/Off Button
When the equipment connected to the product is
operating, turning on the button until the led lights
on and then pressing the button, all equipment
connected to the product is turned off then pres
again and all euipments starts work. For operation
again automatically, the product needs to be
switched from manual control to automatic control
mode as described in chapter 4.
3- Pump Current
The current drawn by the pump can also be
monitored via the digital screen. A standart value is set
for this current, and if the current goes out of tolerance,
the product automatically closes the pump to protect the
pump. To set the current value, turn the button "CAL" on
the display until it comes out, then press the button.
After 1-1.5 minutes of product measurement, calibration
was completed and normal value was obtained. If the
current is out of tolerance, the product stops running the
pump.
Need help?