SWITCHMODE POWER SUPPLY
Type 2220
CONTENTS
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . 16
How to dismantle SYSTEM 2200 . . . . . . . . . . . . . . . . . . . 17
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Electrical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
For further information contact Omni Instruments by phone on
+44 845 9000 601 or via email at info@omniinstruments.co.uk
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au
www.omniinstruments.com.au
UK / Europe Office
Tel: +44 (0)845 9000 601
Fax: +44 (0)845 9000 602
info@omniinstruments.co.uk
www.omniinstruments.co.uk
USA / Canada Office
Tel +1-866-849-3441
Fax +1-866-628-8055
info@omniinstruments.net
www.omniinstruments.net
11

Advertisement

loading

Summary of Contents for PR 2220

  • Page 1: Table Of Contents

    SWITCHMODE POWER SUPPLY Type 2220 CONTENTS Warnings ........12 Safety instructions.
  • Page 2: Warnings

    General mounting, connection and disconnection of wires. Troubleshooting the module. Repair of the module and replacement of circuit breakers must be done by PR electronics A/S only. WARNING! To keep the safety distances, modules with two built-in relays must not be connected to both hazardous and non-hazardous voltages on the same module’s relay contacts.
  • Page 3: Safety Instructions

    To the extent the instructions in this manual are not strictly observed, the All modules fall under Installation Category II, Pollution Degree 1, and Insulation customer cannot advance a demand against PR electronics A/S that would Class II. otherwise exist according to the concluded sales agreement.
  • Page 4: Declaration Of Conformity

    As manufacturer The back panel of the module is detached from the housing by way of a screw- PR electronics A/S driver as shown in picture 1. On a module with knobs, these may have to be removed before the PCB can be Lerbakken 10 taken out as shown in picture 2.
  • Page 5: Applications

    100°C the thermal fuse will automatically switch on the power supply. 207...253 VAC Frequency ........... 50...60 Hz MOUNTING: The 2220 is for standard 11-pole socket mounting in all positions. To achieve Output: maximum cooling, vertical position and a small distance (10 mm) between Output voltage ..........4.75...25.2 VDC neighbouring units are recommended.
  • Page 6: Order

    ORDER: Current limit (short circuit) ......Typ. 2.2 A Output ripple ..........< 20 mVRMS Type Version Output GOST R approval: 2220 110 VAC Special (5...24 V) VNIIM, Cert. No.......... See www.prelectronics.com 230 VAC 24 VDC 24 VAC 15 VDC...
  • Page 7 Displays Programmable displays with a wide se- PR electronics A/S tilbyder et bredt program af analoge og digitale lection of inputs and outputs for display of temperature, signalbehandlingsmoduler til industriel automation. Programmet volume and weight, etc. Feature linearisation, scaling, består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, and difference measurement functions for programming Universaltransmittere mfl...