Hussong Kozy Heat BELLINGHAM 52 Installation And Operation Manual

Hussong Kozy Heat BELLINGHAM 52 Installation And Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

HUSSONG MANUFACTURING CO., INC.
B E L L I N G H A M 5 2
Model #BHM-52
Direct Vent Gas Fireplace
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
ͷ Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
ͷ Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
Hussong Mfg. Co., Inc.
BHM-52 Report No: 19-554
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATION AND
OPERATION MANUAL
This
appliance
an
aftermarket,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
DANGER
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
may
be
installed
permanently
located,
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
Rev.1, May 2020
Starting Serial Number: 20 300000 26
in

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kozy Heat BELLINGHAM 52 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hussong Kozy Heat BELLINGHAM 52

  • Page 1 INSTALLATION AND OPERATION MANUAL HUSSONG MANUFACTURING CO., INC. B E L L I N G H A M 5 2 Model #BHM-52 Direct Vent Gas Fireplace English and French installation manuals are available through your local dealer. Visit our website www.kozyheat.com.
  • Page 3 We recommend you record the following information: Model Name: ____________________________________________ Date purchased/installed: __________________________________ Serial Number: ___________________________________________ Location of fireplace: ______________________________________ Dealership Purchased from: ________________________________ Dealer phone: ___________________________________________ Notes: ______________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 5: Table Of Contents

    14.0 REPLACEMENT PARTS LIST..........70 7.2 Venting Requirements ................41 LIMITED LIFETIME WARRANTY ............ 72 7.3 Natural Draft Vent Restriction ............... 42 7.4 Natural Draft Installation ................43 #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TABLE OF CONTENTS 5...
  • Page 7: Introduction

    Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 7...
  • Page 8: Specifications

    Verify the household breaker is shut off prior to working on any electrical lines. • The AC power supply to this appliance must be hot at all times and shall not have a switch installed in it. 8 SPECIFICATIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 9: Appliance Dimensions

    ¾ ” (349mm) 6” (152mm) ⁄ ⁄ ” ” (618mm) (1489mm) Power Vent Wire Harness Hole (see KPV manual for more information) Figure 2.1, BHM-52 Dimensions #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces SPECIFICATIONS 9...
  • Page 10: Safety Barrier Screen Dimensions

    If the safety barrier screen becomes damaged, the barrier shall be replaced with Hussong Mfg. Co., Inc. barrier for this appliance. For installation instructions, refer to Section 4.2 Safety Barrier Installation on page 34.
  • Page 11: Framing

    Please reference the manual included with your kit before completing all fireplace framing and other installation considerations. Please read the instructions in this manual carefully for your specific installation. #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 11...
  • Page 12: Nailing Flange Assembly And Installation

    Stand-o ange Front View Top View Stand-o ange Nailing ange Framing stud Framing stud ½ ” (89mm) clearance Nailing ange Figure 3.2, Nailing Flange Installation 12 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 13: Stand-Off Assembly And Header Heat Shield

    Contact point for non-combustible material above the fireplace screws previously removed. • Attachment for the header heat shield Figure 3.3, Standard Installation for Stand-off Assembly and Header Heat Shield #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 13...
  • Page 14: Clearances To Combustibles

    (1667mm) (1667mm) Corner Installation ½ ” (673mm) ¼ ” (1378mm) ½ ” ½ ” (1967mm) ⁄ ” (2781mm) 2” (1667mm) (51mm) Figure 3.4, Clearance to Combustibles 14 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 15: Rough Framing

    (2235mm) ⁄ ” Finishing (1667mm) Edge ½ ” (1283mm) ¾ ” ½ ” (730mm) (1283mm) Figure 3.5, Standard Installation Rough Opening Dimensions and TV Recess Construction #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 15...
  • Page 16: Natural Draft Vent Termination Rough Framing

    Please consult the vent manufacturer’s instructions to determine the elbow dimension used for installation. Adjust the wall pass-through rough opening dimensions to maintain clearance requirements. 16 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 17 Figure 3.6, Vent Termination Minimum Framing Clearances Natural gas and propane - rigid pipe Natural draft minimum horizontal terminations ¾ ” (730mm) 73” (1854mm) Figure 3.7, Vent Termination Minimum Framing Dimensions #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 17...
  • Page 18: Outdoor Covered Fireplace Installation

    3.7.1 Safety Screen Barriers Hussong Mfg. Co., Inc. highly recommends to use black painted safety barriers in outdoor installations. Other screen barriers that incorporate a plated or patina finish are highly susceptible to oxidation and discoloration.
  • Page 19 OUTSIDE INSIDE Free standing structure (weatherproof enclosure) Figure 3.9, Outdoor Covered Installation 2 (your fireplace may look different than the one shown) #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 19...
  • Page 20: Heat Distribution Cover Plates

    Remove (1) square cover plate per kit, up to (2) kits may be used. See heat transfer kit manuals (HTK-EXT/HTK-INT) for more information Figure 3.11, Cover Plate Removal Figure 3.10, Heat Transfer Kit Cover Plate Removal (1 shown) 20 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 21: Vented Cavity And Kzk Installation

    Convection air ow with ba e in place Figure 3.12, Air Flow inside Appliance with Convection Baffle Removed Baffle Clip Figure 3.13, Convection Baffle Removal #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 21...
  • Page 22 Please follow local building codes to determine what temperature setting is relevant for your installation. 60” (1524mm) Ceiling Air Discharge Opening Figure 3.14, Clearance from Air Discharge Opening to Sprinkler Head 22 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 23 Front vented cavity option with air discharge in rear Single 3” (76mm) height x 52” (1321mm) width air discarge minimum opening 3” (76mm) 52” (1321mm) Figure 3.16, Vented Cavity Rear to Adjacent Room Installation #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 23...
  • Page 24 (305mm) 3” 88” (76mm) (2235mm) Enclosure *must maintain 3” (76mm) clearance for full length of crown molding/trim projection Figure 3.18, Front Vented Cavity Crown Molding Installation 24 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 25 (2235mm) 8” (203mm) 4” 52” (101mm) Air discharge overhang (1321mm) 6” Air discharge opening (152mm) 60” (1524mm) Figure 3.19, Front Vented Cavity Alternative Installation with Overhang #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 25...
  • Page 26 1½” (38mm) from ceiling on all three sides with the entire top of the chamber 1½” from ceiling ½ ” (38mm) ½ ” (38mm) ½ ” (38mm) Figure 3.20, Top Vented Cavity Installation 26 FRAMING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 27 Air discharge overhang Air discharge overhang Air discharge opening 6” (152mm) Width of replace chamber 8” (203mm) Figure 3.22, Top Vented Cavity Alternative Installation with Overhang #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING 27...
  • Page 28: Facing And Finishing

    NOTE: The surface area above the appliance may be affected by high temperatures emitted from this appliance. To help avoid or reduce the WARNING: Maintain all minimum clearances to combustibles from the possibility of the sheetrock to crack, Hussong Mfg. Co., Inc. recommends appliance and vent system. the following methods: NOTE: See Section 4.3 Vented Cavity and KZK Facing and Finishing...
  • Page 29 (2235mm) 31” (786mm) ½ ” (850mm) ½ ” Bottom (64mm) nishing edge 14” (356mm) Combustible Floor Figure 4.1, Standard Installation Combustible Mantel and Hearth #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 29...
  • Page 30 12” (305mm) 9” (229mm) 6” (152mm) 8” (203mm) 88” Top nishing edge (2235mm) ½ ” (1054mm) Combustible Floor Figure 4.2, Standard Installation Non-combustible Mantel Clearances 30 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 31 88” (2235mm) unlimited 6” (152mm) Figure 4.3, Adjacent Sidewall Clearances #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 31...
  • Page 32 (432mm) ½ ” (1282mm) ⁄ ” (784mm) ⁄ ⁄ ” ” (167mm) (1332mm) ½ ” (63mm) ⁄ ” (1667mm) Figure 4.4, Framed Opening Clearances 32 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 33 (851mm) Combustible material allowed ½ ” (64mm) Combustible material allowed Non-combustible material only Combustible material allowed No screws allowed Figure 4.5, Minimum Finishing Dimensions #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 33...
  • Page 34: Safety Barrier Installation

    • To remove safety barrier screen: lift the screen up and out of slots. Recessed mount Flush mount Figure 4.6, Safety Screen Installation 34 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 35: Vented Cavity And Kzk Facing And Finishing Requirements

    4.3.4 Finishing Recommendations NOTE: The surface area above the appliance may be affected by high temperatures emitted from this appliance. To help avoid or reduce the possibility of the sheetrock to crack, Hussong Mfg. Co., Inc. recommends the following methods: •...
  • Page 36 (786mm) ½ ” (850mm) ½ ” Bottom (64mm) nishing edge 14” (356mm) Combustible Floor Figure 4.7, Vented Cavity & KZK Facing and Finishing Clearances 36 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 37 88” Top nishing edge (2235mm) Bottom nishing edge Figure 4.8, Combustible Wall Finish up to 1" (25mm) thick #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 37...
  • Page 38: Gas Line Connection

    5” WC (1.25 kPa) 10.5” WC (2.62 kPa) 7” WC (1.74 kPa ) recommended Propane 12” WC (2.99 kPa) 13” WC (3.24 kPa) recommended 38 GAS LINE CONNECTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 39: Natural Draft Termination Locations

    Over 12/12 to 14/12 1.52 Over 14/12 to 16/12 1.83 Over 16/12 to 18/12 2.13 Over 18/12 to 20/12 2.27 Over 20/12 to 21/12 2.44 #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces NATURAL DRAFT TERMINATION LOCATIONS 39...
  • Page 40: Minimum Natural Draft Vent Termination Clearances

    ‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. VINYL SOFFIT, VINYL CEILING, AND VINYL OVERHANG DISCLAIMER: Clearances to heat resistant material (i.e. wood, metal). This does not include vinyl. Hussong Manufacturing Co., Inc.
  • Page 41: Venting

    These wall thimble products may be insulated using unfaced insulation products listed as noncombustible per ASTM E 136. #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces VENTING 41...
  • Page 42: Natural Draft Vent Restriction

    Remove all inner rings for the least restriction Insert restrictor plate into 5” (127mm) exhaust pipe in firebox ceiling with tabs facing towards you Figure 7.1, Restrictor Plate Installation 42 VENTING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 43: Natural Draft Installation

    (4) 45° elbows may be used. No 90° elbows are allowed. For 3’ (914mm) every 45° elbow used, 18” (457mm) must be subtracted from maximum venting allowed. 50’ (15.24m) 3’ (914mm) #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces VENTING 43...
  • Page 44 (1.83m) (152mm) 24” 6” (610mm) (152mm) 36” (914mm) Vent Pipe 24” (610mm) Vent Pipe 12’ 25’ 6” (7.62m) (3.66m) 6” (152mm) (152mm) 25’ 48” (7.62m) (1219mm) 44 VENTING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 45 25’ (7.6m) maximum vertical rise + 25’ (7.6m) maximum horizontal run = 50’ (15.2m) of total length Figure 7.2, Natural Gas and Propane Natural Draft Combination Venting #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces VENTING 45...
  • Page 46: Fireplace Setup

    VALANCE AGAINST UNIT TO TOP LATCH ASSEMBLY ALL FOUR LATCHES SECURING VALANCE Figure 8.2, Gas Valve Access Cover Plate Figure 8.1, Glass Frame Assembly Removal 46 FIREPLACE SETUP Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 47: Panel Installation

    Figure 8.3, Back Refractory Panel Installed Figure 8.5, Side Black Glass Panels Installed Figure 8.4, Side Refractory Panel Installed #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FIREPLACE SETUP 47...
  • Page 48: Bh52-500 Log Set Installation

    Studs for log BH52-7 Log stop bracket Studs for log BH52-2 Studs for log BH52-5 Figure 8.6, Burner Stud Locations and Log Stop Brackets Figure 8.7, Base Logs 48 FIREPLACE SETUP Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 49 Align log BH52-10 with the notches on logs BH52-9 and BH52-6 (Figure 8.9), and place as shown in Figure 8.10. Figure 8.8, Base Log Notches Figure 8.9, Notches log BH52-10 #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FIREPLACE SETUP 49...
  • Page 50 Figure 8.10, Completed Log Set 50 FIREPLACE SETUP Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 51: Control Board Access, Removal And Installation

    Remove the media tray. Instructions continue on the next page. Figure 8.12, Control Board Removal and Installation - 1 #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FIREPLACE SETUP 51...
  • Page 52 14. Reconnect electrical power. 15. Verify proper log placement, operation of fireplace, and any electrical components. Figure 8.13, Control Board Removal and Installation - 2 52 FIREPLACE SETUP Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 53: Electrical Information

    National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. Figure 9.1, Wiring Schematics #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ELECTRICAL INFORMATION...
  • Page 54: Outlet Junction Box

    Remove the media tray. Install (6) halogen bulbs (included in component packet) into lamp bases. Reinstall media tray. Reinstall glass frame assembly and safety barrier. 54 ELECTRICAL INFORMATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 55: Top Light Kit #600-Tlk

    Figure 9.3, Top Light Kit Location YELLOW FEMALE CONNECTORS RED MALE CONNECTORS BLUE FEMALE CONNECTORS RED MALE CONNECTORS (from control module) Figure 9.4, Top Light Kit Wiring #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ELECTRICAL INFORMATION...
  • Page 56: Operating Instructions

    This fireplace may produce noises of varying degree as it heats and cools due to metal expansion and contraction. This is normal, and does not affect the performance or longevity of the fireplace. 56 OPERATING INSTRUCTIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 57: Setup Proflame

    Once replaced, the IFC module will emit a ‘beep’ as soon as it is powered. LEFT SIDE Remote learn button ON/OFF Toggle Switch Figure 10.1, ON/OFF Toggle Switch and Remote Learn Button Location #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces OPERATING INSTRUCTIONS 57...
  • Page 58: Control System 7 Day Timeout

    Press the remote control down arrow key during flame adjustment mode to reduce the flame to OFF (indicated by OFF displayed on the LCD screen). 58 OPERATING INSTRUCTIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 59: Remote Control Operation

    LCD screen. Simultaneously press the mode key and the up arrow key to activate or deactivate this function. #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces OPERATING INSTRUCTIONS 59...
  • Page 60 HI. A single ‘beep’ will confirm reception of the command. Flame Off Flame Level 1 Flame Level 5 Flame Level Maximum 60 OPERATING INSTRUCTIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 61 The temperature bulb graphic will not be displayed on the LCD screen. • To reactivate remote thermostat operation, follow the same key sequence procedure above. The temperature bulb graphic will reappear on the LCD screen. #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces OPERATING INSTRUCTIONS 61...
  • Page 62 Press the up arrow key to turn the ember bed light kit ON. Press the down arrow key to turn the ember bed light kit OFF. A single ‘beep’ will confirm reception of the command. 62 OPERATING INSTRUCTIONS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 63: Adjustment

    Low - High Low - High Manifold Pressure 1.1” - 3.8” WC 2.9” - 11” WC Tap (B) (0.27 - 0.95 kPa) (0.72 - 2.74 kPa) #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ADJUSTMENT 63...
  • Page 64: Burner Flame Adjustments

    Venturi settings(s) closed too far. Open venturi(s) slightly OR gas pressure too high - check manometer settings Figure 11.2, Burner Venturis Figure 11.3, Flame Appearance and Characteristics 64 ADJUSTMENT Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 65 (127mm) exhaust pipe. Make necessary modifications to achieve desired flame appearance. Insert restrictor plate into the 5” (127mm) exhaust pipe with the tabs pointing towards you. Reinstall all components previously removed. #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ADJUSTMENT 65...
  • Page 66: Troubleshooting

    Remote control not working Replace batteries. properly No call for heat Verify remote control is powered ON and thermostat operation is turned OFF. 66 TROUBLESHOOTING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 67 A maximum number of failed Reset IFC module. Refer to Section 10.7 IFC Module Ignition Sequence ignitions or flame restorations has on page 58. been reached #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces TROUBLESHOOTING 67...
  • Page 68: Maintenance

    Replace the glass and the assembly #701-050T as necessary. NOTE: If the vent-air intake system is disassembled for any reason, • Only Hussong Mfg. Co., Inc. will supply the replacement of glass reinstall per instructions provided with installation. If Installing Kozy assembly as a complete unit.
  • Page 69: Burner And Pilot System

    Figure 13.2, Pilot and Burner Correct Flame Appearance safety system. It must de-energize the safety shutoff in no more than (30) seconds. Burner Ports Burner ori ce Figure 13.1, Burner System #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces MAINTENANCE...
  • Page 70: Replacement Parts List

    BH52-005 SAFETY BARRIERS Safety Barrier Screen (only) BH52-ES Hussong Manufacturing Co., Inc. P.O. Box 577 204 Industrial Park Drive Lakefield, MN 56150-0577, USA BHM-52 70 REPLACEMENT PARTS LIST Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces #BHM-52 R.1 May 2020...
  • Page 71 BLACK GLASS PANEL SET Black Glass Panel Set BH52-BG900 Hussong Manufacturing Co., Inc. P.O. Box 577 204 Industrial Park Drive Lakefield, MN 56150-0577, USA BHM-52 #BHM-52 R.1 May 2020 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces REPLACEMENT PARTS LIST 71...
  • Page 72: Limited Lifetime Warranty

    10. It is expressly agreed and understood that this warranty is Hussong Mfg. ’ s sole obligation and purchaser’s exclusive remedy for defective fireplace equipment. Hussong Mfg. is free of liability for any damages caused by this appliance, as well as inconvenience expenses and materials.

This manual is also suitable for:

Kozy heat bhm-52

Table of Contents