Summary of Contents for DDC BU-65570T
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
Specifications are subject to change without notice. 105 Wilbur Place, Bohemia, New York 11716-2426 For Technical Support - 1-800-DDC-5757 ext. 7771 Headquarters - Tel: (631) 567-5600, Fax: (631) 567-7358 United Kingdom - Tel: +44-(0)1635-811140, Fax: +44-(0)1635-32264...
Page 3
RECORD OF CHANGE Revision Date Pages Description 10/2001 Original Issue 3/2002 vii, 25 Corrections 2/2003 Fig 1 Additions 8/2005 Table 2 Update Added inlet air minimum to the system 8/2009 requirements. New manual format applied. Data Device Corporation BU-65572T Manual Artisan Technology Group - Quality Instrumentation ...
Windows 2000 ......................14 Hardware Configuration ....................18 5 DDC 1553 CARD MANAGER FOR 95/98/2000 ............19 6 DDC 1553 CARD MANAGER FOR WINDOWS NT ..........22 7 HARDWARE OPERATION ..................25 General ........................25 Bus Controller Mode ....................25 7.2.1 Minor and Major Frames ...................
Page 5
7.7.1 Variable Amplitude Transceiver ................ 32 7.7.2 IRIG-B Support ....................32 7.7.3 IRIG-B Specifications ..................33 7.7.4 Monitor DMA to Host Buffer ................34 7.7.5 Software Control of Bus Configuration .............. 34 7.7.6 Discrete Outputs ....................35 8 APPENDIX A ......................36 9 APPENDIX B ......................
Page 6
Figure 18. Found Driver ....................17 Figure 19. Finished Install of Driver ................17 Figure 20. Control Panel ....................19 Figure 21. DDC 1553 Card Manager ................20 Figure 22. Card Manager Modify .................. 20 Figure 23. Control Panel ....................22 Figure 24.
Page 7
LIST OF TABLES Table 1. J2: 1553 Bus 'D' Connector ................4 Table 2. J1: Discrete I/O ....................5 Data Device Corporation BU-65572T Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
For the full text of this manual, BU-65572T will be used to identify both the BU-65572T and the BU-65570T. In those cases where there is a difference, the appropriate part number will be identified.
Fax: 44 (1635) 32264 Asia/Pacific: Tel: 81 (3) 3814-7688 Fax: 81 (3) 3814-7689 DDC also has an Internet World Wide Web site, which allows customers to easily download new revisions of software and documentation. The Internet address is www.ddc-web.com. Data Device Corporation...
There is additional capability to synchronize the onboard time tags of all of the operating cards with one command. Included with each BU-65572T CompactPCI Card is the DDC Menu and the Run Time Library with example source. The library supports „C‟ and LabView programming.
O V E R V I E W System Requirements A CompactPCI compatible Backplane with an 80386 or better host CPU. Windows 95, 98, NT, or 2000 operating system. One available CompactPCI Peripheral Slot in the Backplane. cPCI slot must provide inlet air at 1 m/s minimum with a temperature between 0°C to 55°C.
HARDWARE INSTALLATION The BU-65572T card is a CompactPCI Peripheral device and may be inserted into any PICMG 2.0 R3.0 or higher, compatible slot. When installing the card, the following should be observed: NEVER insert or remove the card with the power turned on. ALWAYS take proper precautions to guard against static damage.
CH1_TXB CH1_TXB_L GND (connected to shell) CH2_TXA_L CH2_TXA CH2_TXB CH2_TXB_L Discrete I/O Connector “J1” Model BU-65570T includes a Front-Panel mounted Discrete I/O connector “J1”. This connector (Soldered on the board) is a 40-Pin “Subminiature Type” (Amp 787170-4). numbering designations for “J1” are as shown below.
Page 14
D R I V E R I N S T A L L A T I O N Table 2. J1: Discrete I/O Description Description Chassis Ground Chassis Ground IRIG-In IRIG Mod Chassis Ground Chassis Ground Channel 2 BC Trigger Out Channel 2 Monitor Trigger In Channel 2 BC Trigger In Channel 2 Monitor Trigger Out...
DRIVER INSTALLATION Windows 95/98 If you have Windows 95/98 continue with the following installation instructions. If you are using another operating system, skip to the relevant installation section. 1) Install the card as described in the beginning of the HARDWARE INSTALLATION section.
D R I V E R I N S T A L L A T I O N Figure 3. Search for Driver 5) Click on Search for the best driver for your device. 6) Click on the Next button. Figure 4.
D R I V E R I N S T A L L A T I O N 7) Insert the BUS-69068 Installation Disk. 8) Select the Floppy disk drives option. 9) Select the Specify a location option. 10) Type the path of the BUS-69068 Installation Disk; i.e. A:\ 11) Click on the Next button to locate the BU-65572T-300 device driver.
D R I V E R I N S T A L L A T I O N Figure 6. Finished Install of Driver 13) Click on the Finish button to confirm the installation. Figure 7. Confirm Driver Installation Data Device Corporation BU-65572T Manual Artisan Technology Group - Quality Instrumentation ...
14) Click on the Finish button to close the Add New Hardware Wizard. 15) Continue configuring the device by installing the BUS-69068 RTL software, which includes the DDC 1553 Card Manager. 16) Proceed with the DDC 1553 Card Manager instructions for 95/98/2000. Windows NT 4.0 If you have Windows NT 4.0, continue with the following installation...
D R I V E R I N S T A L L A T I O N Figure 8. Welcome Screen 9) The setup screen shows the software you are about to install. Click the Next button to start the installation process. Figure 9.
D R I V E R I N S T A L L A T I O N Figure 10. Destination Location 11) This screen shows where the software will be installed. You can accept the default folder, or choose your own destination by clicking the Browse button.
D R I V E R I N S T A L L A T I O N 12) Select which components you want installed and click the Next button to continue. Figure 12. Program Folder Selection 13) Select the program folder location where Icons are to be installed. Click the Next button to continue.
14) Click the Finish button to finish the installation. Figure 14. Restart Computer 15) Once the computer has rebooted, start the card manager dialog and Click the Driver button. Proceed with the DDC 1553 Card Manager instructions for Windows NT. Windows 2000 If you have Windows 2000 continue with the following installation instructions.
D R I V E R I N S T A L L A T I O N Figure 15. Found New Hardware 4) Click on the Next button. Figure 16. Search for Driver 5) Click on Search for a suitable driver for my device. Data Device Corporation BU-65572T Manual Artisan Technology Group - Quality Instrumentation ...
D R I V E R I N S T A L L A T I O N 6) Click on the Next button. Figure 17. Specify Driver Location 7) Insert the BUS-69068 Installation Disk. 8) Select the Floppy disk drives option. 9) Select the Specify a location option.
Figure 19. Finished Install of Driver 13) Click on the Finish button to confirm the installation. 14) Continue configuring the device by installing the BUS-69068 RTL software or the BUS-69065 TestSim Menu which includes the DDC 1553 Card Manager. Data Device Corporation BU-65572T Manual Artisan Technology Group - Quality Instrumentation ...
In order to access an installed card you must assign it a device number. Setting up the DDC 1553 Card Manager is shown in the RTL (BUS-69068) manual, Test/Sim GUI (BUS- 69065) manual and the following section.
Windows 95/98 and 2000. If you are using Windows NT skip to the NT section. The DDC 1553 Card Manager is used to set a device number (logical number) for the card you are using. This number is used by the RTL to identify the card.
1 5 5 3 C A R D M A N A G E R F O R W I N 9 5 / 9 8 / 2 0 0 0 Figure 21. DDC 1553 Card Manager 4) Select an installed Device (i.e. BU-65572T-300) and click the Modify button.
Page 30
1 5 5 3 C A R D M A N A G E R F O R W I N 9 5 / 9 8 / 2 0 0 0 7) When finished, click on the OK button. 8) The DDC 1553 Card Manager window should display the device with a device number mapped to the card. The card status should read Device Ready.
Panel. The following are basic instructions to configure a card in Windows NT. The DDC 1553 Card Manager is used to set a device number (logical number) for the card you are using. This number is used by the RTL to identify the card.
1 5 5 3 C A R D M A N A G E R F O R W I N D O W S N T Figure 24. DDC 1553 Card Manager 3) Click on the Driver button to specify the driver type of the card.
7) After selecting a Device Number, click on the Ok button. Your device is now set and ready to use. To exit out of the DDC 1553 card Manager click on the Close button. Data Device Corporation BU-65572T Manual Artisan Technology Group - Quality Instrumentation ...
HARDWARE OPERATION General BU-65572T next generation CompactPCI Tester/Simulator which can simultaneously simulate a MIL-STD-1553 BC, all RTs, and an intelligent MT simultaneously on two 1553 buses. Full error detection features are provided in all modes of operation. In addition, user specified errors including bit count and Manchester II errors may be injected in BC and any of the emulated RT modes.
H A R D W A R E O P E R A T I O N special operations that should be performed at that point. For example the symbol „END_OF_MINOR‟ specifies that the BC must stop message processing until the minor frame time counter expires. Then, once the timer expires, the counter is reset with the Minor frame time, and the next message in the list will be processed.
H A R D W A R E O P E R A T I O N completion of the current message. The user may define an asynchronous message after the END_OF_MAJOR frame symbol or choose a message in the active frame. The message is inserted into the running frame by calling the „ddcInsertMessage‟...
H A R D W A R E O P E R A T I O N channels. The BU-65572T maintains "last status" and "last command" words allowing for full support of transmit last command and transmit status mode commands. The BU-65572T supports full RT command illegalization for each transmit or receive message based on RT address and sub-address.
H A R D W A R E O P E R A T I O N The BU-65572T supports three types of response errors: no response, a late response, or a response on the wrong bus. No response errors may be programmed for a single bus (Bus A or Bus B) or for both buses.
H A R D W A R E O P E R A T I O N of „last‟ is reached, at which point the current table number will rollover to the value of first. The incrementing of the current data table is accomplished through the use of an intermessage routine.
H A R D W A R E O P E R A T I O N As interrupts are generated, the BU-65572T device driver will acknowledge the interrupt by clearing the computer hardware and then enter an interrupt vector onto a queue that can contain up to 64 interrupt actions.
H A R D W A R E O P E R A T I O N 7.6.3 Monitor Interrupts Monitor interrupts may be generated after each message is received or after one third of the monitor's circular buffer has been filled (approximately 4K words).
1st word is time-of-year in BCD notation including days, hours, minutes, seconds, and fractions of seconds DDC Usage - Mode B, Not using Straight Binary Seconds Range = 1 Second to 1 Year The initial time is 0 days, 0 hours, 0 minutes, 0 seconds on January...
H A R D W A R E O P E R A T I O N 7.7.4 Monitor DMA to Host Buffer The BU-65572T is fully compliant to the PCI standards for both Target and Master applications. As a PCI master, the BU-65572T is capable of performing DMA block data transfers from the monitor buffers on the card to a user buffer in the host memory.
H A R D W A R E O P E R A T I O N 7.7.6 Discrete Outputs This new Tester/Simulator design includes four discrete outputs per channel. These four outputs are set to logic „1‟ and cleared to logic „0‟ by use of eight intermessage routines.
Page 45
APPENDIX A Data Device Corporation BU-65572T Manual Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
APPENDIX B Acronyms ACARS Aircraft Communication, Addressing and Reporting System ACMS Aircraft Condition Monitoring System MIL-STD-1553 Aeronautical Radio Inc. Automated Test Equipment Color Graphics Adapter Central Maintenance Computer CMOS Complementary Metal Oxide Semiconductor Chip Set DADC Digital Air Data Computer Disk Operating System DPRAM Dual-Port Random Access Memory...
Page 48
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...