HEAT WAVE DUCT KIT
KIT # 946-556 & 946-753
Approved for use with the following
City 40 Series, City 60 Series, City 72 Series, HZ33CE, HZ54E, HZ40E, P33, P33CE, P33E,
P36, P36E, P36D, P90, U900E, U1500E, G800EC and G800C
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to this manual. For assistance or additional information
consult an authorized installer, service agency or the gas
supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours
and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an author-
ized installer, service agency or the gas supplier.
Tested by: Intertek
C#4001172
918-023q
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
www.regency-fire.com
Gas Fireplace
FOR YOUR SAFETY
What to do if you smell gas:
* Do not try to light any appliance
* Do not touch any electrical switch: do not
use any phone in your building.
* Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call
the fire department.
Manufactured by:
FPI Fireplace Products International Ltd.
6988 Venture St.,
Delta, B.C. Canada, V4G 1H4
Models:
06.17.20

Advertisement

Table of Contents
loading

Summary of Contents for Regency HEAT WAVE 946-556

  • Page 1 HEAT WAVE DUCT KIT KIT # 946-556 & 946-753 www.regency-fire.com Gas Fireplace Approved for use with the following Models: City 40 Series, City 60 Series, City 72 Series, HZ33CE, HZ54E, HZ40E, P33, P33CE, P33E, P36, P36E, P36D, P90, U900E, U1500E, G800EC and G800C...
  • Page 2: Listings And Code Approvals

    LISTINGS AND CODE GENERAL 3) This kit is tested and safe when installed APPROVALS INFORMATION in accordance with this installation manual. Please read all instructions before starting installation and follow all instructions care- This Kit has been approved for use with the The Heat Wave Air Duct Kit increases the ef- fully during installation.
  • Page 3 MINIMUM FRAMING CLEARANCES * Wall studs must be 16" on center for mounting fan housing. * Fan Housing: Maintain a 1/4" (6mm) clearance from fan housing to combustible material. * Wall Registers must be 4"(102mm) from floor above or ceiling below. Minimum Framing Clearances Model 14"...
  • Page 4: Installation

    2) Attach assembly to unit in location shown below with 4 screws. INSTALLATION 2) Bend the tabs outward. NOTE: Heatwave adaptor may be installed on either left or right side. A) For Models; (Using Side Exit) HZ54E, HZ33CE, HZ40E, P33, P33CE, P33E, P36, P36E, P36D, U900E, U1500E, G800EC and G800C.
  • Page 5 5. Connect the flex pipe to the adaptor with 3 For new version (no knockout) screws. No knockout - 4 holes only 2a. Follow these steps for CB60 and CV60 models with the hole pattern shown 6. Attach flex pipe to duct collar with three above on the outer body.
  • Page 6 The first 24" of duct pipe (from the unit) must be covered with insulation. Round Air Duct: Attach the 6" round air duct (supplied) to the fireplace collar and run the duct to the fan housing. Attach the round-to-oval adaptor to the fan housing and the air duct to the adaptor, diagram 3.
  • Page 7: Wiring Diagram

    WIRING DIAGRAM NOTE: The wires (in dotted lines) and wire nuts are supplied by others. Ground Lug Caution: Ensure that the wires do Do not cut the ground terminal CAUTION: Label all wires prior not touch any hot surfaces and off under any circumstances.
  • Page 8 © Copyright 2020, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...