5
QQ
3 7 63 1515 0
Description of
FL
Error
39 SGC converge
timeout
41 Spindle timeout
48 Spindle FG transition
timeout
49 Spindle PLL
transition timeout
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB.
Auto sequence
51
timeout of peak
detection
Auto sequence
52
timeout of focus
jump down
Auto sequence
timeout of focus
53
jump up
54 Auto sequence
timeout of play AGC
Auto sequence
55
timeout of disc-type-
sensing
56 Auto sequence
timeout of ATB2
TE
L 13942296513
Auto sequence
57
timeout of tracking
servo ON
58 Auto sequence
timeout of ATB1
Auto sequence
59
timeout of focus gain
adjustment
Auto sequence
5A
timeout of tracking
gain adjustment
Auto sequence
5B
timeout of offset
adjustment
Auto sequence
timeout of
5C
modulation factor
measurement
Auto sequence
5D
timeout of auto focus
bias
5F Auto sequence
already busy
62 Pause retry error
71 ID reading check
during playback
Subcode check
www
failure during
72
playback
73 ID can not read
during startup
.
5
http://www.xiaoyu163.com
6
Causes if with a DVD
SGC could not converge during detects the peak
The unit did not enter Stop mode within 10 seconds of issuance of a Stop command.
Disc distinction is not completed even if passes for 10 seconds after the spindle turned.
Did not reach to the rotating speed that ATB was
possible for less than 10 seconds. Did not reach aim
CAV lock speed (high: 10%, low: 50%) for less than 10
seconds. CAV process passed more than 5 seconds or
abnormal speed was detected. Spindle does not lock for
less than 3 seconds in the BCA read start or end.
CAV process passed more than 5 seconds. Abnormal speed was detected.
ABUSY did not return within 1 second after the DDTCT
(peak detection) command was sent.
ABUSY did not return within 30 mS after the FJMPD
(Focus jump 1 to 0) command was sent.
ABUSY did not return within 30 mS after the FJMPU
(Focus jump 0 to 1) command was sent.
ABUSY did not return within 50 mS after the GSUMON
(play-AGC-measuring) command was sent.
ABUSY did not return within 2 seconds after the
DJSRT (disc-sensing) command was sent.
ABUSY did not return within 1 second after the
TBLOFS (Internal ATB after the completion of external
ATB) command was sent.
ABUSY did not return within 0.5 sec. after the TSON
(tracking servo ON) command was sent.
ABUSY did not return within 0.2 sec. after the TBL
(external ATB) command was sent.
ABUSY did not return within 2 seconds after the FGN
(focus gain adjustment) command was sent.
ABUSY did not return within 2 seconds after TGN
(tracking gain adjustment) command was sent.
ABUSY did not return within 1 second after the AVE
(offset adjustment) command was sent.
ABUSY did not return within 200 mS after the ADJMIR
(modulation factor measurement) command was sent.
ABUSY did not return within 2 seconds after the AFB
(auto focus bias) command was sent.
A command could not be sent because ABUSY was
low. ABUSY did not return within 200 mS after TLV
command was sent.
Pause mode could not be restored within three retries
after it had been released.
An ID could not be read for 1 second or more.
x
ao
u163
An ID could not be read within 1 second after the AFB
y
tracking on.
i
6
http://www.xiaoyu163.com
7
2 9
8
Causes if with a CD
Q Q
3
6 7
1 3
1 5
No frame could be read for 3
seconds or more.
co
.
DV-45A
7
9 4
2 8
Operation of the Unit
Open
Stop
Stops. (FG timeout)
Stops.
("73" is displayed during
starting process.)
Stops.
("73" is displayed during
starting process.)
Stop
Open
Open
Stop
Stop
Stop
0 5
8
2 9
9 4
2 8
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Continues operation
Stop
m
Stop
Opens
(ID readout failure)
8
9 9
A
B
C
9 9
D
E
F
73