45 mm and 55 mm tubular motors with electronic limit switch and radio receiver

Advertisement

Quick Links

USER AND MAINTENANCE MANUAL
Ø 45 mm and Ø55 mm tubular motors with electronic limit switch and radio receiver
Dear Customer, thank you for purchasing a STAFER product. This manual describes the operations necessary for the correct
installation of the V6RX.E
most popular types of rolling shutters. The motor's technical specifications are shown on the label affixed to the motor tube.
These devices have not been designed for round-the-clock use. Any use of the product other than what is provided herein is
improper and prohibited, and involves warranty voidance and liability disclaimer by the Manufacturer. The product must be
assembled and installed only by a qualified technician. At the end of installation, all the manuals accompanying the product
must be delivered to the end customer, who must keep them for future reference. Visit the site www.stafer.com to view updated
documents, if any.
Index
01. Technical specifications of motors and remote controls
02. Warnings
03. Rating tables and motor components
04. Electrical connection
05. Some information on motor operation
06. Movement control functions
07. Installation via command buttons
08. Installation via remote control
09. Add/delete a radio device
10. Upper limit switch fine-tuning
11. Lower limit switch fine-tuning
12. Button logic
13. Third limit switch (preferred position)
14. Third limit switch inversion
15. Sun/wind anemometer
16. Radio test for anemometer
17. Shutter release
18. Orientation (micro movements)
19. Reset to factory values
Let's protect the environment
Protecting the environment is everyone's duty! STAFER uses recyclable packaging materials. Dispose of materials in proper
containers, in compliance with laws in force in your location. If you are an installer and use a large number of motors, ask your
dealer or the Company about receiving motors in "honeycomb pads", an environmentally friendly choice that limits clutter and
waste by significantly reducing the amount of packaging materials. This product may contain substances that are polluting for
the environment and dangerous to health. At the end of the product life cycle, carefully comply with the appropriate waste
disposal rules. It is hazardous, and thus strictly forbidden to dispose of the product in the domestic waste.
Notes on radio systems
It is advisable to avoid using radio systems in areas with strong interference (for example, near police stations, airports, ports,
banks, etc.). A technical inspection is in any case advisable before installing any radio system in order to identify sources of
interference. Radio systems can be used where possible disturbances or malfunctioning of the transmitter or the receiver do
not cause a risk factor, or if the risk factor is cancelled by suitable safety systems. The presence of radio devices operating on
the same transmission frequency (433.42 MHz) can interfere with the radio receiver of the device and thus reduce the range of
the system and limit the functionality of the entire system.
01. TECHNICAL SPECIFICATIONS
The motor's technical features are shown on the label affixed to the motor tube. Before installing the motor, we recommend that
you copy the technical data (including the full product name) and store them in a safe place. These data could be useful at the
time of maintenance or technical assistance. Additional features common to the V6RX.E
Power supply
Idle consumption
Minimum V6RX.E roller diameter : 50 x 1.5 mm
Minimum V7RXE roller diameter
recycled paper
V6
RX.E
/ V7RX.E
products. These tubular motors with electronic limit switches are suitable for handling the
3
3
: 230 Vac 50 Hz
Protection grade
: < 0,5W
Insulation class
Maximum limit switch revolutions : ∞
: 60 x 1.5 mm
Revolving operating time
- V7
3
3
RX.E
Compatible STAFER remote controls
595.T.X1.00
(1 channel)
www.stafer.com
: IP44
: H
: 4 minutes
01
596.T.X1.00
(1 channel)
596.T.X5.00
595.M.X1.00
(15 channels)
(1 channel)
VIDEO TUTORIAL
/V7RX.E
motor family.
3
3
Radio frequency
Storable portable transmitters
Storable sun/wind radio sensors:
: 433.42 MHz
: 40
: 1
version 1.0

Advertisement

loading
Need help?

Need help?

Do you have a question about the V6RX.E3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stafer V6RX.E3

  • Page 1 At the end of installation, all the manuals accompanying the product must be delivered to the end customer, who must keep them for future reference. Visit the site www.stafer.com to view updated documents, if any.
  • Page 2 Motor accessories, adapters and supports must be selected exclusively from the STAFER catalogue. ● If the product is installed at a height of less than 2.5 m from the floor or other supporting surface, it is necessary to protect the moving parts with a cover, in order to prevent accidental access.
  • Page 3: Main Power Supply

    At the time of printing of this document, no particular problems concerning the connection between STAFER SPA products and home automation control units are known (if the above rules are complied with). In any case, STAFER shall not be liable in the event of lack of compatibility (even partial) with any home automation control unit. If the home automation control unit uses KNX or similar protocols, contact the home automation system supplier to discuss the rules listed above.
  • Page 4 05. SOME INFORMATION ON MOTOR OPERATION The STAFER motor adjusts its operating principle according to the type of rolling shutter in which it is installed (blind, square bar awning or cassette awning). Operation in BLIND mode The motor activates the obstacle detection system during the ascent phase. If during the ascent phase an obstacle is detected in the vicinity of the lower limit switch, the ascent manoeuvre is interrupted and the motor operates in descent mode, bringing the blind back to the lower limit switch position (the motor interprets the obstacle as an anti-intrusion stop).
  • Page 5 08. INSTALLATION VIA REMOTE CONTROL We recommend thoroughly reading the entire procedure before performing the described operations, so as to make the procedure easier and less prone to errors. The product must be installed only by a qualified technician. This motor is compatible with remote controls of the 595 and 596 series. If in doubt, contact your supplier.
  • Page 6 10. FINE-TUNING OF UPPER LIMIT SWITCH WARNING: Fine-tuning of the upper limit switch is not possible if the limit switch has been set by contact with a stop plate. 10.1 USING THE REMOTE CONTROL 01. Bring the motor to the intermediate position. MENU 3 x PROG 02.
  • Page 7 13. THIRD LIMIT SWITCH (PREFERRED POSITION) In the case of blinds with ADJUSTABLE slats, it is possible to decide whether to associate the THIRD LIMIT SWITCH to the fully lowered blind position with open slats or to the lowered blind position with closed slats. In any case, it is better to initially associate the THIRD LIMIT SWITCH to the completely lowered position with slats closed, since the LOWER limit switch has already been stored and associated with the completely lowered blind position with open slats.
  • Page 8 17. SHUTTER RELEASE (FOR CASSETTE AWNINGS ONLY) Threshold This is a specific function available only in the CASSETTE AWNING installation mode. The factory sets this function as “inactive”. If the No. of movements function is activated, when the cassette closes a very brief downward movement is commanded so as to reduce the traction on the Function not active shutter with closed cassette.
  • Page 9 All products and technical specifications given in this document are subject to variation without prior notice. Unless previously and specifically authorised by STAFER, the device must be used exclusively with transmitters produced by STAFER. STAFER cannot be considered responsible for damage caused by improper, incorrect or unreasonable uses.