At the end of the product life cycle, dispose of the device in compliance with local regulations. This product could contain substances that are harmful to human health and the
environment: do not dispose of the product in domestic waste.

TECHNICAL SPECIFICATIONS

1.

Power supply :

Contact capacityi :
Grade of protection :

2. WARNINGS ON SAFETY

- All the product installation, connection, programming and maintenance operations must be carried out only by a qualified and skilled technician, who must comply with laws,
provisions, local regulations and the instructions given on this manual.
- Check that the package is intact and has not suffered damages in transit
- Make connections with power supply disconnected
- Adjust the limit switches of the motor before connecting it to the module
- Use momentary (hold-to-run) control buttons. Do NOT use stay-put switches. Command buttons are connected to the main voltage, so they must be properly insulated and
protected Position the buttons withing sight of the roller shutter/awning but a long way from its moving parts. Position the buttons more than 1.5 m from the floor
- You cannot connect more than one motor directly to the module. If it is necessary to connect more than one motor to the module use the appropriate expansion cards.
- The supply line must be equipped with a circuit breaker. The installer must fit an isolation device (with 3,5 mm minimum opening on the contacts) upstream of the system
- Do not modify or replace parts without the manufacturer's permission.
- For your safety, do not work near the winding roller while the motor is powered
- The product is designed to be inserted inside of junction boxes. The module does not provide any protection against water and only essential protection for contact with solids. It
is forbidden to install the module in areas not adequately protected, near sources of heat
- Check that the power supply does not depend from electrical circuits for lighting
- The product doesn't provide any protection against overloads or short circuits. You must provide, on the supply line, an adequate protection to the load, for example a fuse
of maximum value 3,15 A
2.1. Power supply
The module can be powered at 120 Vac or 230 Vac. The supply voltage must be applied to terminals 1 and 2.

2.2. Connecting the motor

The motor windings must be connected to the terminals 7 and 8, the common wire of the motor must be connected to terminal 1. You can not connect more than one motor directly to the
module. If it is necessary to connect more than one motor to the module use the appropriate expansion cards.

2.3. Connecting the S single commands buttons

The single command buttons must be connected to terminals 5 and 6, the common thread of the buttons must be connected to terminal 1. The command buttons are subject to the mains voltage
and therefore must be properly insulated and protected. You must use momentary (hold-to-run) button, do not use buttons with maintained position. More than one command button can be
connected to the unit through a parallel connection. For the correct operation of the system it is necessary to check that the closure of the button connected to terminal 6 (▲ S, up single) matches
the upward movement of the motor, if not, invert the wires of the motor windings to the terminals 7 and 8.

2.4. Connecting the G general commands buttons

The general command buttons must be connected to terminals 3 and 4 and must close on terminal 1. You must use momentary (hold-to-run) button, do not use buttons with maintained
position. More general command buttons can be connected via a parallel connection.
120-230V
50-60Hz
L
1
GENERAL
command
L
N
POWER SUPPLY
recycled paper
User manual for 590.C.SM.00 centralization module

WARNINGS

Dear Customer, thank you for purchasing a STAFER spa product.
This guide contains all the information you will need concerning the use of this product. Read the instructions carefully and keep them for further
consultation. The module 590.C.SM.00 is specially designed for the control of a tubular motor with mechanical limit switches. All other use beyond the
field defined by STAFER S.p.A. is forbidden. This, as well as the breach of the instructions given in this guide, shall release STAFER S.p.A. from any liability
and shall annul the product warranty.
120 o 230 Vac 50/60 Hz
10 A@250 Vac
Dimensions :
IP20
Operating temperature :
MAX 7A
590CSM0
230V
N
M
G
G
S
S
2
3
4
5
6
7
8
manoeuvre 1
manoeuvre 2
SINGLE
command
from 1 s to 250 s
44 x 38 x 25 mm
from -20°C to +55°C
120-230V
590CSM0
50-60Hz
L
N
G
G
S
S
1
2
3
4
5
6
1
MAX 7A
230V
M
7
8
manoeuvre 1
manoeuvre 2
SINGLE
command
versione 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 590.C.SM.00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stafer 590.C.SM.00

  • Page 1 The module 590.C.SM.00 is specially designed for the control of a tubular motor with mechanical limit switches. All other use beyond the field defined by STAFER S.p.A. is forbidden. This, as well as the breach of the instructions given in this guide, shall release STAFER S.p.A. from any liability and shall annul the product warranty.
  • Page 2 3. OPERATING LOGIC OF THE BUTTONS Single and general command buttons can operate in two different operating logics: "impulse" mode or "hold-to-run" mode. The procedure to select the operating logic of the buttons is described in Section 4.4 ("selection of the operating logic of the buttons"). The factory sets the buttons in the "impulse" mode. "Impulse"...
  • Page 3 4.3. «Air change» function If the module is used for the movement of roller shutters, it can be useful to activate this function. Pressing briefly for 2 times (less than 0.5 sec) in quick succession button ▼ S, the module lowers the roller shutter and, at the end of working time, it commands a small upward movement, such as to permit ventilation.
  • Page 4 Tutti i prodotti e le specifiche tecniche citati in questo documento sono soggetti a variazioni senza preavviso. Salvo concessioni e casi specifici concordati preventivamente con STAFER, il dispositivo deve essere utilizzato esclusivamente con apparecchiature trasmittenti della STAFER. STAFER non può essere considerato responsabile per eventuali danni derivanti da usi impropri, erronei o irragionevoli.

Table of Contents