Symptom: You are feeling too cold (hot) in your living room ..19 ▪ Do NOT place any objects containing water on the unit. Symptom: The water at the tap is too cold ........ 19 Symptom: Heat pump failure ............. 20 User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
Latest revisions of the supplied documentation may be available on the regional ROTEX website or via your installer. RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...
▪ Enables you to activate or deactivate a function lock if pressed for more than 5 seconds in the main menu of the menu structure. INFORMATION If you press while changing settings, the changes will NOT be applied. User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
Then… Room temperature control Main (+ additional) leaving water temperature control is automatically turned ON. Main (+ additional) leaving water Room temperature control is temperature control NOT automatically turned ON. RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...
(method 1) the home page. Linked by their preset values. You can set Check the installer settings table filled in by the installer. the preset values in the menu structure. User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
Page 7
▪ Room temperature on the external thermostat control See also: ▪ Leaving water temperature on the user interface (ROTEX) ▪ "Using the room temperature home page" on page 7 ▪ "To set the overrule period" on page 8 To control the leaving water temperature, you can do the following: ▪...
Page 8
2 hours the schedule will be used ▪ Permanent again. ▪ hours (2, 4, 6, 8) If user profile = Basic, then you can temporarily overrule the room temperature schedule by pressing User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
NOT be successful and the applicable warning AH will be Typical leaving water temperature home pages generated. Main zone: User profile = Basic User profile = Detailed RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...
DHW tank temperature decreases again. home page ▪ At 00:00 the next day, the cycle repeats. Condition: is displayed on the DHW tank temperature home page. Activate the DHW tank booster mode. User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
In scheduled + reheat mode, you can do the following: You can… Location DHW tank temperature Time Do the same things as in scheduled mode. — Adjust the preset value (Reheat). Menu structure RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...
Day schedule used during your holiday. schedule Then you can activate the DHW tank booster mode. Example: Saturday Advantage: The DHW tank immediately starts heating up the water to the preset value (Storage comfort). User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
> User settings > Unit of measurement. 2 When you go away again, activate the holiday mode again. Advantage: You do NOT have to change your schedule or holiday configuration. RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...
You can use the following locking modes: ▪ Child lock: Locks all buttons to prevent children from changing settings. ▪ Function lock: Locks a specific function to prevent people from changing its settings. User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
4 Save it. 3 Set the days you want to copy to Yes and press . Example: Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday = Yes. RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...
4 Operation Menu structure: Overview user settings Time Holiday mode Holiday mode LWT main Energy metering Produced energy Contact/helpdesk number Indoor unit Temperature lock Backlit LCD time LWT main LWT main RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...
▪ For longer periods: You can use the holiday mode. Example: When you stay at home during your holiday, or when you go away during your holiday. User reference guide RGSQH10S18AA9W ROTEX HPU ground 4P374247-1 – 2014.03...
Program Example: Go to [6.3.2]: > Information > Error handling > Contact/helpdesk additionally heat number. DHW tank to a preset value (Storage eco = lower tank temperature) during the day. RGSQH10S18AA9W User reference guide ROTEX HPU ground 4P374247-1 – 2014.03...