  • Page 1 User manual Eole T5 + HV460 EUROPE PROJECTION - 228, avenue Olivier Perroy 13790 ROUSSET - Tél : +33 (0)4 42 29 08 96 – Fax : +33 (0)4 42 53 44 36 SAS au capital de 400 000 € - RCS Aix-en-Provence B 394 961 510 - NAF 2892 Z - Intracom : FR 54 394 961 510...
  • Page 2: Table Of Contents

    4.4. Setting up of the extension pole .........p.12 4.5. Change of the atomization kit ........p.12 5. CLEANING AND MAINTENANCE ........p.13 6. DECLARATION OF CONFORMITY ........p.14 7. WARRANTY CONDITIONS ..........p.15 User manual - Eole T5 + HV460 202005-418-ENG...
  • Page 3: User Manual

    - people in charge of the use of the machine - people in charge of the cleaning and maintenance of the machine - people in charge of the final destruction of the machine 202005-418-ENG User manual - Eole T5 + HV460...
  • Page 4: Warning

    • For any replacement of parts, only use genuine parts. • Do not modify the machine. • Do not cut or dismantle the protection grids. • Do not open the electric box. User manual - Eole T5 + HV460 202005-418-ENG...
  • Page 5 • Keep the equipment in a clean and clear area in which the temperature does not exceed +35°C. IN CASE OF NECESSITY, WE SAVE OURSELVES THE RIGHT TO MAKE ANY USEFUL MODIFICATION WITHOUT ADVANCED NOTICE. 202005-418-ENG User manual - Eole T5 + HV460...
  • Page 6: Electric Connection

    EEEs according to the following provisions: applicable only to products on the market since 08/13/05, under the brands EUROPE PROJECTION or VOLUMAIR, products of other brands sold by our company (upon presentation of the corresponding invoices), products that operate using electrical energy (for example, thermal washers or compressors do not fall into this category).
  • Page 7: Your Machine

    19 kg Noise level 89 Lwa SPRAY-GUN Product flow-rate adjustment Jet width adjustment Air pressure adjustment Bowl capacity Dimensions (L x w x h) 18 x 11 x 29 cm Weight 0,83 kg 202005-418-ENG User manual - Eole T5 + HV460...
  • Page 8: Identification Of The Spray-Gun Components

    3. YOUR MACHINE (continued) 3.3. IDENTIFICATION OF THE SPRAY-GUN COMPONENTS Nozzle ring 1 litre bowl Trigger Air inlet coupling Product flow-rate adjustment thumbwheel Atomization kit Diffuser head Jet nozzle Needle Air flow-rate adjustment thumbwheel User manual - Eole T5 + HV460 202005-418-ENG...
  • Page 9: Identification Of The Turbine Components

    3. YOUR MACHINE (continued) 3.4. IDENTIFICATION OF THE TURBINE COMPONENTS Ventilation filter / Bowl filling support Air outlet coupling Starting switch Potentiometer Thermal circuit breaker Electrical supply cable Air filter 202005-418-ENG User manual - Eole T5 + HV460...
  • Page 10: Use Of The Machine

    Before each use, atomize some water before using the paint to be sprayed. • The EOLE T5 + HV460 set can be used to spray bactericidal products (bleach, etc.). In this case it is imperative to respect the following rules: •...
  • Page 11: Atomization

    Mat ceiling paint 25 to 30 sec. Cellulosic 18 to 22 sec. Anti-rust 25 to 33 sec. Chromate and Wash-primer 18 to 22 sec. Impression 20 to 25 sec. Metallised 18 to 20 sec. 202005-418-ENG User manual - Eole T5 + HV460...
  • Page 12: Spray Setting

    • Reassemble the spray-gun in the reverse order of the disassembly, with the new diffuser head. Changing of the atomization kit, verify that the jet nozzle and the needle have the same diameter. User manual - Eole T5 + HV460 202005-418-ENG...
  • Page 13: Cleaning And Maintenance

    The direct projection of water under pressure onto the control panel has to be stopped at the risk of water infiltration into the electric box. Proceed by simply cleaning with a humid sponge. 202005-418-ENG User manual - Eole T5 + HV460...
  • Page 14: Declaration Of Conformity

    Tél : +33 (0)4 42 29 08 96 – Fax : +33 (0)4 42 53 44 36 SAS au capital de 400 000 € - RCS Aix-en-Provence B 394 961 510 - NAF 2892 Z - Intracom : FR 54 394 961 510 User manual - Eole T5 + HV460 202005-418-ENG...
  • Page 15: Warranty Conditions

    Any action of the customer against us relating to the guarantee of the equipments will be prescribed within the period of 1 year as from the day of the discovery of the defect. It is up to the customer to prove the day of this discovery. 202005-418-ENG User manual - Eole T5 + HV460...